Identificador persistente para citar o vincular este elemento: http://hdl.handle.net/10553/47154
Campo DC Valoridioma
dc.contributor.authorCueva-Mestanza, Rubénen_US
dc.contributor.authorTorres-Padrón, M. E.en_US
dc.contributor.authorSosa-Ferrera, Z.en_US
dc.contributor.authorSantana-Rodriguez, J. J.en_US
dc.contributor.otherTorres-Padron, Maria Esther-
dc.contributor.otherZoraida, Sosa-Ferrera-
dc.date.accessioned2018-11-23T11:16:15Z-
dc.date.available2018-11-23T11:16:15Z-
dc.date.issued2008en_US
dc.identifier.issn0269-3879en_US
dc.identifier.urihttp://hdl.handle.net/10553/47154-
dc.description.abstractA simple and specific analytical method was developed and tested for the determination of pharmaceuticals in mollusc samples. A combination of microwave‐assisted micellar extraction (MAME) and solid‐phase extraction (SPE) using a non‐ionic surfactant, polyoxyethylene 10 lauryl ether, was examined to extract and determine simultaneously a group of pharmaceuticals such as carbamazepine, clorfibric acid, ketoprofen, naproxen, bezafibrate and ibuprofen by liquid chromatography using UV‐diode array detector. The MAME extraction performance was evaluated by studying various parameters such as the volume and concentration of surfactant and microwave conditions. Finally, an OASIS HLB cartridge was used as an optimum SPE sorbent to clean up the extracts and preconcentrate the selected analytes. The proposed method showed satisfactory linearity and reproducibility (between 3 and 15%), as well as detection limits ranging from 30 to 220 ng/g. Finally, the method was successfully applied to the determination of the target pharmaceuticals in various kinds of mollusc samples. This study has demonstrated that microwave‐assisted micellar extraction with solid‐phase extraction may be used as a viable alternative to conventional methods for the extraction of pharmaceuticals in this type of matrices.en_US
dc.languageengen_US
dc.relationAcoplamiento de la Microextracción en Fase Sólida y la Cromatografía Líquida de Alta Resolución Con la Utilización de Medios Micelares Como Extractantes: Desarrollo de Nuevos Métodos Analíticosen_US
dc.relation.ispartofBiomedical Chromatographyen_US
dc.sourceBiomedical Chromatography [ISSN 0269-3879], v. 22, p. 1115-1122en_US
dc.subject2301 química analíticaen_US
dc.subject2391 Química ambientalen_US
dc.subject.otherPharmaceutical residuesen_US
dc.subject.otherMolluscsen_US
dc.subject.otherMicrowave-assisted micellar extractioen_US
dc.subject.otherSolid-phase extractioen_US
dc.subject.otherHPLC-UV-DADen_US
dc.titleMicrowave-assisted micellar extraction coupled with solid-phase extraction for preconcentration of pharmaceuticals in molluscs prior to determination by HPLCen_US
dc.typeinfo:eu-repo/semantics/Articleen_US
dc.typeArticleen_US
dc.identifier.doi10.1002/bmc.1033en_US
dc.identifier.scopus58149172109-
dc.identifier.isi000260522400009-
dcterms.isPartOfBiomedical Chromatography-
dcterms.sourceBiomedical Chromatography[ISSN 0269-3879],v. 22 (10), p. 1115-1122-
dc.contributor.authorscopusid23484796600-
dc.contributor.authorscopusid8452532700-
dc.contributor.authorscopusid6602897915-
dc.contributor.authorscopusid56248783900-
dc.description.lastpage1122en_US
dc.description.firstpage1115en_US
dc.relation.volume22en_US
dc.investigacionCienciasen_US
dc.type2Artículoen_US
dc.identifier.wosWOS:000260522400009-
dc.contributor.daisngid6395925-
dc.contributor.daisngid22437017-
dc.contributor.daisngid2812385-
dc.contributor.daisngid770178-
dc.contributor.daisngid10914640-
dc.contributor.daisngid745012-
dc.identifier.investigatorRIDE-9038-2012-
dc.identifier.investigatorRIDN-1602-2014-
dc.identifier.externalWOS:000260522400009-
dc.utils.revisionen_US
dc.contributor.wosstandardWOS:Cueva-Mestanza, R-
dc.contributor.wosstandardWOS:Torres-Padron, ME-
dc.contributor.wosstandardWOS:Sosa-Ferrera, Z-
dc.contributor.wosstandardWOS:Santana-Rodriguez, JJ-
dc.date.coverdateDiciembre 2008en_US
dc.identifier.ulpgcen_US
dc.contributor.buulpgcBU-VETen_US
dc.description.jcr1,592-
dc.description.jcrqQ3-
dc.description.scieSCIE-
item.grantfulltextnone-
item.fulltextSin texto completo-
crisitem.project.principalinvestigatorSosa Ferrera, María Zoraida-
crisitem.author.deptGIR IUNAT: Análisis Químico Medioambiental-
crisitem.author.deptIU de Estudios Ambientales y Recursos Naturales-
crisitem.author.deptDepartamento de Química-
crisitem.author.deptGIR IUNAT: Análisis Químico Medioambiental-
crisitem.author.deptIU de Estudios Ambientales y Recursos Naturales-
crisitem.author.deptDepartamento de Química-
crisitem.author.deptGIR IUNAT: Análisis Químico Medioambiental-
crisitem.author.deptIU de Estudios Ambientales y Recursos Naturales-
crisitem.author.deptDepartamento de Química-
crisitem.author.orcid0000-0001-7000-4419-
crisitem.author.orcid0000-0003-3003-3607-
crisitem.author.orcid0000-0002-5635-7215-
crisitem.author.parentorgIU de Estudios Ambientales y Recursos Naturales-
crisitem.author.parentorgIU de Estudios Ambientales y Recursos Naturales-
crisitem.author.parentorgIU de Estudios Ambientales y Recursos Naturales-
crisitem.author.fullNameTorres Padrón, María Esther-
crisitem.author.fullNameSosa Ferrera, María Zoraida-
crisitem.author.fullNameSantana Rodríguez, José Juan-
Colección:Artículos
Vista resumida

Citas SCOPUSTM   

39
actualizado el 10-nov-2024

Citas de WEB OF SCIENCETM
Citations

31
actualizado el 10-nov-2024

Visitas

110
actualizado el 05-oct-2024

Google ScholarTM

Verifica

Altmetric


Comparte



Exporta metadatos



Los elementos en ULPGC accedaCRIS están protegidos por derechos de autor con todos los derechos reservados, a menos que se indique lo contrario.