Please use this identifier to cite or link to this item: http://hdl.handle.net/10553/47135
Title: Optimisation of an in-tube solid phase microextraction method coupled with HPLC for determination of some oestrogens in environmental liquid samples using different capillary columns
Authors: Aufartová, J.
Torres-Padron, M. E. 
Sosa-Ferrera, Z. 
Solich, P.
Santana-Rodríguez, J. J. 
UNESCO Clasification: 2301 química analítica
2391 Química ambiental
Keywords: Oestrogens
Eendocrine disruptor chemicals (EDCs)
In-tube SPME,
Sea water
Effluent of wastewater treatment plant, et al
Issue Date: 2012
Publisher: 0306-7319
Project: Desarrollo de Nuevas Estrategias de Extracción en El Análisis de Residuos Farmacéuticos.Implementación en Muestras Reales de Interés Medioambiental. 
Journal: International Journal of Environmental Analytical Chemistry 
Conference: 36th International Symposium on Environmental Analytical Chemistry 
Abstract: A simple on-line method for simultaneous determination of some oestrogens including oestriol (E3), norethisterone (NORE), ethynylestradiol (EE2), D-norgestrel (NORG) and bisphenol A (BPA), in environmental liquid samples was developed by coupling in-tube solid phase microextraction (in-tube SPME) to high-performance liquid chromatography with diode array (DAD) and fluorescence (FLD) detectors. Two capillary chromatographic columns (Supel-Q™ and Carboxen™ 1006 porous layer open tubular) were selected to develop this method. To achieve optimum extraction performance, several parameters were investigated including number of draw/eject cycles and the sample volume for each of the columns. Reproducibility was satisfactory for inter- and intra-day precision, yielding % RSDs of less than 10% and 7.6%, respectively. Limits of detection (LODs) and quantification (LOQs) for the proposed method using a DAD detector were achieved in the ranges of 0.04–0.63 ng mL−1 and 0.12–1.9 ng mL−1, depending of the capillary column used. Fluorescence detection improved these parameters for E3, BPA and EE2, obtaining LODs of 0.005–0.03 ng mL−1 and LOQs of 0.015–0.08 ng mL−1 using Supel-Q and LODs of 0.01–0.015 ng mL−1 and LOQs of 0.025–0.04 ng mL−1 using Carboxen. The proposed method was successfully applied to spiked environmental waters obtaining recoveries greater than 80%.
URI: http://hdl.handle.net/10553/47135
ISSN: 0306-7319
DOI: 10.1080/03067319.2011.585714
Source: International Journal Of Environmental Analytical Chemistry [ISSN 0306-7319], v. 92 (4), p. 382-396
Appears in Collections:Artículos
Show full item record

Page view(s)

79
checked on Feb 3, 2024

Download(s)

12
checked on Feb 3, 2024

Google ScholarTM

Check

Altmetric


Share



Export metadata



Items in accedaCRIS are protected by copyright, with all rights reserved, unless otherwise indicated.