dc.contributor.author | Rodriguez de Castro, F. | en_US |
dc.contributor.author | Sole Violan, Jorge | en_US |
dc.contributor.author | Capuz, B. L. | en_US |
dc.contributor.author | Luna, J. C. | en_US |
dc.contributor.author | Rodriguez, B. G. | en_US |
dc.contributor.author | Alonso, J. L.M. | en_US |
dc.date.accessioned | 2018-11-23T07:10:29Z | - |
dc.date.available | 2018-11-23T07:10:29Z | - |
dc.date.issued | 1991 | en_US |
dc.identifier.issn | 0090-3493 | en_US |
dc.identifier.uri | http://hdl.handle.net/10553/46698 | - |
dc.description.abstract | Objective: To assess the usefulness of the telescoping plugged catheter in the diagnosis of nosocomial pneumonia. Design: Prospective study. Patients: A total of 103 ventilated patients with suspected pneumonia were prospectively studied over 20 months. Results: The quantitative cultures of the protected brush specimen detected pulmonary bacterial infection (greater than 10(3) cfu/mL) in 49 (47.5%) patients. Subsequent follow-up confirmed pneumonia in 41 patients; in only one patient was a positive protected brush specimen culture established as a false-positive result. There were 54 patients with less than 10(3) cfu/mL and the diagnosis was excluded in 36 of them. We identified eight patients with false-negative protected brush specimen cultures. The results obtained by this technique allowed us to modify treatment in 49 (47.5%) patients. Conclusions: The telescoping plugged catheter demonstrated significant bacterial infection in a relatively small proportion of patients in whom bacterial lung infection was suspected. This technique can be safely performed and is a sensitive and specific method to establish the cause of pneumonia, thus allowing specific treatment and the avoidance of inappropriate antibiotic therapy. | en_US |
dc.language | eng | en_US |
dc.relation.ispartof | Critical Care Medicine | en_US |
dc.source | Critical Care Medicine[ISSN 0090-3493],v. 19, p. 171-175 | en_US |
dc.subject | 32 Ciencias médicas | en_US |
dc.subject | 3205 Medicina interna | en_US |
dc.subject | 3213 Cirugía | en_US |
dc.subject.other | Bronchoscopy | en_US |
dc.subject.other | Catheter brush | en_US |
dc.subject.other | Pneumonia | en_US |
dc.subject.other | Mechanically ventilated patients | en_US |
dc.title | Reliability of the bronchoscopic protected catheter brush in the diagnosis of pneumonia in mechanically ventilated patients | en_US |
dc.type | info:eu-repo/semantics/article | en_US |
dc.type | Article | en_US |
dc.identifier.doi | 10.1097/00003246-199102000-00010 | en_US |
dc.identifier.scopus | 0025972903 | - |
dc.contributor.authorscopusid | 55942667000 | - |
dc.contributor.authorscopusid | 7801493602 | - |
dc.contributor.authorscopusid | 55181391800 | - |
dc.contributor.authorscopusid | 7005926186 | - |
dc.contributor.authorscopusid | 23010105300 | - |
dc.contributor.authorscopusid | 57197099864 | - |
dc.description.lastpage | 175 | en_US |
dc.description.firstpage | 171 | en_US |
dc.relation.volume | 19 | en_US |
dc.investigacion | Ciencias de la Salud | en_US |
dc.type2 | Artículo | en_US |
dc.description.numberofpages | 5 | en_US |
dc.utils.revision | Sí | en_US |
dc.date.coverdate | Febrero 1991 | en_US |
dc.identifier.ulpgc | Sí | en_US |
dc.contributor.buulpgc | BU-MED | en_US |
dc.description.scie | SCIE | |
item.grantfulltext | none | - |
item.fulltext | Sin texto completo | - |
crisitem.author.dept | GIR IUIBS: Patología y Tecnología médica | - |
crisitem.author.dept | IU de Investigaciones Biomédicas y Sanitarias | - |
crisitem.author.dept | Departamento de Ciencias Médicas y Quirúrgicas | - |
crisitem.author.dept | GIR IUIBS: Patología y Tecnología médica | - |
crisitem.author.dept | IU de Investigaciones Biomédicas y Sanitarias | - |
crisitem.author.dept | GIR IUIBS: Patología y Tecnología médica | - |
crisitem.author.dept | IU de Investigaciones Biomédicas y Sanitarias | - |
crisitem.author.dept | Departamento de Ciencias Médicas y Quirúrgicas | - |
crisitem.author.orcid | 0000-0002-6812-2739 | - |
crisitem.author.orcid | 0000-0002-0483-4470 | - |
crisitem.author.orcid | 0000-0002-2931-9483 | - |
crisitem.author.parentorg | IU de Investigaciones Biomédicas y Sanitarias | - |
crisitem.author.parentorg | IU de Investigaciones Biomédicas y Sanitarias | - |
crisitem.author.parentorg | IU de Investigaciones Biomédicas y Sanitarias | - |
crisitem.author.fullName | Rodríguez De Castro, Felipe Carlos B. | - |
crisitem.author.fullName | Sole Violan,Jorge | - |
crisitem.author.fullName | Caminero Luna, José Antonio | - |
Colección: | Artículos |
Citas SCOPUSTM
65
actualizado el 10-nov-2024
Citas de WEB OF SCIENCETM
Citations
62
actualizado el 10-nov-2024
Visitas
76
actualizado el 17-ago-2024
Google ScholarTM
Verifica
Altmetric
Comparte
Exporta metadatos
Los elementos en ULPGC accedaCRIS están protegidos por derechos de autor con todos los derechos reservados, a menos que se indique lo contrario.