Please use this identifier to cite or link to this item: http://hdl.handle.net/10553/46676
Title: Usefulness of microscopic examination of intracellular organisms in lavage fluid in ventilator-associated pneumonia
Authors: Sole Violan, Jorge 
De Castro, F. R. 
Rey, A.
Martin-Gonzalez, J. C.
Cabrera-Navarro, P. 
UNESCO Clasification: 32 Ciencias médicas
320508 Enfermedades pulmonares
Keywords: Protected Specimen Brush
Continuous Mechanical Ventilation
Bronchoalveolar Lavage
Nosocomial Pneumonia
Bacterial Pneumonia, et al
Issue Date: 1994
Journal: Chest (American College of Chest Physicians) 
Abstract: Study objective: To assess the usefulness of quantification of bronchoalveolar lavage (BAL) cells containing intracellular organisms (ICO) in the diagnosis of ventilator-associated pneumonia. Design: The reliability of cytologic analysis in comparison with the protected specimen brush (PSB) and BAL quantitative cultures has been assessed in a prospective study. Setting: An intensive care unit of a tertiary-referral teaching hospital. Patients: A total of 33 ventilated patients with suspected pneumonia based on clinical grounds and radiographic findings. Interventions: All patients underwent fiberoptic bronchoscopy within the first 24 h after clinical suspicion of pneumonia. Specimens were obtained by PSB and BAL and were processed for quantitative cultures using standard methods. Two 0.5-ml samples of resuspended original BAL fluid were centrifuged and stained with Gram and modified May-Grünwald-Giemsa for differential cell counts and percentage of cells with ICO. Results: Pneumonia was the final diagnosis in 16 (49 percent) of the 33 patients. In 14 (42 percent) patients, pneumonia was excluded and in the remaining 3 the diagnosis was uncertain. Twelve of the 16 patients with pneumonia had their conditions diagnosed by PSB, 14 by BAL, and 10 by quantification of ICO. Only one patient's condition was diagnosed exclusively by cytologic examination. There were no false-positive results with any of the diagnostic techniques. Conclusions: Microscopic identification of ICO in cells recovered by BAL allows early and accurate diagnosis of pneumonia in mechanically ventilated patients. However, the sensitivity of this technique is lower than with either PSB or BAL.
URI: http://hdl.handle.net/10553/46676
ISSN: 0012-3692
DOI: 10.1378/chest.106.3.889
Source: Chest[ISSN 0012-3692],v. 106, p. 889-894
Appears in Collections:Artículos
Show full item record

Google ScholarTM

Check

Altmetric


Share



Export metadata



Items in accedaCRIS are protected by copyright, with all rights reserved, unless otherwise indicated.