Identificador persistente para citar o vincular este elemento: http://hdl.handle.net/10553/46356
Campo DC Valoridioma
dc.contributor.authorPérez‐Peña, J.en_US
dc.contributor.authorHernández‐Brito, J. J.en_US
dc.contributor.authorHerrera‐Melián, J. A.en_US
dc.contributor.authorCollado‐Sánchez, C.en_US
dc.contributor.authorvan den Berg, C. M.G.en_US
dc.date.accessioned2018-11-23T03:48:16Z-
dc.date.available2018-11-23T03:48:16Z-
dc.date.issued1994en_US
dc.identifier.issn1040-0397en_US
dc.identifier.urihttp://hdl.handle.net/10553/46356-
dc.description.abstractThe voltammetric determination of trace metals in seawater suffers from the interference of dissolved oxygen and engine vibrations onboard ship. It is here attempted to overcome these interferences using a high‐frequency (1 to 20 kHz) staircase modulation during the voltammetric scan (high‐performance adsorptive cathodic stripping voltammetry, HPACSV). Comparative experiments using the square‐wave modulation showed that this modulation was not effective at such a high frequency. A comparison between various complexing agents (DMG and nioxime) and pH buffers (HEPES/NH4OH, borate/NaOH, and TEA/NH4OH) showed that the determination of nickel and cobalt was similarly improved by the high‐speed potential scan in all conditions. Fast potential scans cause a large increase of the peak area and peak heights using staircase modulation. The peaks are wider, and the peak potentials are shifted toward negative values due to the ohmic drop, but the analytical determination is not disturbed. Optimal sensitivity for the determination of cobalt and nickel in seawater was obtained using TEA buffer and DMG as the adsorptive ligand. The nioxime wave was found to interfere in the cobalt peak at high scan rates so that this ligand is not recommended for HPACSV. Comparative tests showed that the sensitivity for nickel and cobalt determinations was highly improved by the fast scan rates. Furthermore, the reduction current of dissolved oxygen was partially masked so that measurements could be taken without a previous purge of the sample. Finally, the scans were insensitive to the solution turbulence so measurements could be readily carried out onboard of an oceanographic vessel or without switching off the stirrer. Low levels of nickel (2 nM) could be determined in seawater by using a deposition time of 20 seconds and of 120 seconds for 0.05 nM cobalt from turbulent and unpurged solutions. A fast determination method for labile nickel and cobalt is proposed.en_US
dc.languageengen_US
dc.publisher1040-0397-
dc.relation.ispartofElectroanalysisen_US
dc.sourceElectroanalysis [ISSN 1040-0397], v. 6, p. 1069-1076en_US
dc.subject230331 Química del aguaen_US
dc.subject.otherSeawateren_US
dc.subject.otherCathodic stripping voltammetryen_US
dc.titleHigh‐Performance adsorptive cathodic stripping voltammetry of nickel and cobalt in seawateren_US
dc.typeinfo:eu-repo/semantics/Articlees
dc.typeArticlees
dc.identifier.doi10.1002/elan.1140061126
dc.identifier.scopus84860887198-
dc.identifier.isiA1994PZ32300025
dc.contributor.authorscopusid7004839316-
dc.contributor.authorscopusid35614212100-
dc.contributor.authorscopusid55666370900-
dc.contributor.authorscopusid6507645656
dc.contributor.authorscopusid56615830700-
dc.contributor.authorscopusid7101982433-
dc.description.lastpage1076-
dc.description.firstpage1069-
dc.relation.volume6-
dc.investigacionCienciasen_US
dc.type2Artículoen_US
dc.contributor.daisngid1479300
dc.contributor.daisngid1860348
dc.contributor.daisngid5556548
dc.contributor.daisngid5698325
dc.contributor.daisngid170218
dc.contributor.wosstandardWOS:PEREZPENA, J
dc.contributor.wosstandardWOS:HERNANDEZBRITO, JJ
dc.contributor.wosstandardWOS:HERRERAMELIAN, JA
dc.contributor.wosstandardWOS:COLLADOSANCHEZ, C
dc.contributor.wosstandardWOS:VAN DEN BERG, CMG
dc.date.coverdateEnero 1994
dc.identifier.ulpgces
dc.description.scieSCIE
item.fulltextSin texto completo-
item.grantfulltextnone-
crisitem.author.deptGIR IUNAT: Fotocatálisis y espectroscopía para aplicaciones medioambientales.-
crisitem.author.deptIU de Estudios Ambientales y Recursos Naturales-
crisitem.author.deptGIR Tecnologías, Gestión y Biogeoquímica Ambiental-
crisitem.author.deptGIR IUNAT: Fotocatálisis y espectroscopía para aplicaciones medioambientales.-
crisitem.author.deptIU de Estudios Ambientales y Recursos Naturales-
crisitem.author.deptDepartamento de Química-
crisitem.author.deptGIR Tecnologías, Gestión y Biogeoquímica Ambiental-
crisitem.author.deptDepartamento de Química-
crisitem.author.orcid0000-0003-1889-2281-
crisitem.author.orcid0000-0002-5305-1667-
crisitem.author.orcid0000-0002-2466-6531-
crisitem.author.orcid0000-0002-6237-2358-
crisitem.author.parentorgIU de Estudios Ambientales y Recursos Naturales-
crisitem.author.parentorgDepartamento de Química-
crisitem.author.parentorgIU de Estudios Ambientales y Recursos Naturales-
crisitem.author.parentorgDepartamento de Química-
crisitem.author.fullNamePérez Peña,Jesús-
crisitem.author.fullNameHernández Brito, José Joaquín-
crisitem.author.fullNameHerrera Melián, José Alberto-
crisitem.author.fullNameCollado Sánchez, Cayetano-
Colección:Artículos
Vista resumida

Citas SCOPUSTM   

18
actualizado el 21-abr-2024

Citas de WEB OF SCIENCETM
Citations

18
actualizado el 25-feb-2024

Visitas

106
actualizado el 30-mar-2024

Google ScholarTM

Verifica

Altmetric


Comparte



Exporta metadatos



Los elementos en ULPGC accedaCRIS están protegidos por derechos de autor con todos los derechos reservados, a menos que se indique lo contrario.