dc.contributor.author | Herrera-Melián, J. A. | en_US |
dc.contributor.author | Hernández-Brito, J. | en_US |
dc.contributor.author | Gelado-Caballero, M. D. | en_US |
dc.contributor.author | Pérez-Peña, J. | en_US |
dc.date.accessioned | 2018-11-23T03:47:12Z | - |
dc.date.available | 2018-11-23T03:47:12Z | - |
dc.date.issued | 1994 | en_US |
dc.identifier.issn | 0003-2670 | en_US |
dc.identifier.uri | http://hdl.handle.net/10553/46354 | - |
dc.description.abstract | A fast, sensitive method to determine Co (II) in unpurged ocean seawater is presented. The method combines high scan speed staircase voltammetry (HSACSV) and nitrite catalytic effect to enhance Co(II)-dimethylglyoxime reduction currents. The catalytic effect was magnified using high speed adsorptive cathodic stripping voltammetry and peak currents of ca. 0.1 μA were obtained for pM cobalt samples using 30-s deposition times. The effect of buffer, pH, nitrite concentration and scan speed on cobalt sensitivity was studied. Capacitance currents developed at high scan speeds were filtered by background subtraction. The same procedure was successfully applied to remove oxygen interference in unpurged solutions. Blank voltammograms were obtained in different ways yielding similar results without variation in peak reproducibility or accuracy. Nickel and zinc interferences were removed using a cleaning potential before the scan at −1.03 V. Ratios over 10 000 fold were eliminated using more negative cleaning potential steps. Nickel can also be measured by this method. Total analysis time of unpurged seawater (pM levels of cobalt) was decreased to reagents addition time, 30-s adsorption period and 10-s quiescence time. A detection limit of 5.9 pM Co was achieved in seawater. Short analysis time, sensitivity and portable hardware recommend this method for aboard determinations of cobalt. An oceanic profile of cobalt was measured at the Central East Atlantic Ocean. | en_US |
dc.language | eng | en_US |
dc.publisher | 0003-2670 | - |
dc.relation.ispartof | Analytica chimica acta (Print) | en_US |
dc.source | Analytica Chimica Acta [ISSN 0003-2670], v. 299, p. 59-67 | en_US |
dc.subject | 230331 Química del agua | en_US |
dc.subject.other | Stripping voltammetry | en_US |
dc.subject.other | Cathodic stripping voltammetry | en_US |
dc.subject.other | Cobalt | en_US |
dc.subject.other | Nickel | en_US |
dc.subject.other | Seawater | en_US |
dc.subject.other | Waters | en_US |
dc.title | Direct determination of cobalt in unpurged oceanic seawater by high speed adsorptive cathodic stripping voltammetry | en_US |
dc.type | info:eu-repo/semantics/Article | es |
dc.type | Article | es |
dc.identifier.doi | 10.1016/0003-2670(94)00397-1 | |
dc.identifier.scopus | 0028567785 | - |
dc.identifier.isi | A1994QA05300007 | |
dc.contributor.authorscopusid | 55666370900 | - |
dc.contributor.authorscopusid | 35614212100 | - |
dc.contributor.authorscopusid | 6506058559 | - |
dc.contributor.authorscopusid | 7004839316 | - |
dc.description.lastpage | 67 | - |
dc.description.firstpage | 59 | - |
dc.relation.volume | 299 | - |
dc.investigacion | Ciencias | en_US |
dc.type2 | Artículo | en_US |
dc.contributor.daisngid | 5556548 | |
dc.contributor.daisngid | 1860348 | |
dc.contributor.daisngid | 2134468 | |
dc.contributor.daisngid | 1479300 | |
dc.contributor.wosstandard | WOS:HERRERAMELIAN, JA | |
dc.contributor.wosstandard | WOS:HERNANDEZBRITO, J | |
dc.contributor.wosstandard | WOS:GELADOCABALLERO, MD | |
dc.contributor.wosstandard | WOS:PEREZPENA, J | |
dc.date.coverdate | Diciembre 1994 | |
dc.identifier.ulpgc | Sí | es |
dc.description.scie | SCIE | |
item.grantfulltext | none | - |
item.fulltext | Sin texto completo | - |
crisitem.author.dept | GIR IUNAT: Fotocatálisis y espectroscopía para aplicaciones medioambientales. | - |
crisitem.author.dept | IU de Estudios Ambientales y Recursos Naturales | - |
crisitem.author.dept | Departamento de Química | - |
crisitem.author.dept | GIR Tecnologías, Gestión y Biogeoquímica Ambiental | - |
crisitem.author.dept | GIR Tecnologías, Gestión y Biogeoquímica Ambiental | - |
crisitem.author.dept | Departamento de Química | - |
crisitem.author.dept | GIR IUNAT: Fotocatálisis y espectroscopía para aplicaciones medioambientales. | - |
crisitem.author.dept | IU de Estudios Ambientales y Recursos Naturales | - |
crisitem.author.orcid | 0000-0002-2466-6531 | - |
crisitem.author.orcid | 0000-0002-5305-1667 | - |
crisitem.author.orcid | 0000-0003-4001-9673 | - |
crisitem.author.orcid | 0000-0003-1889-2281 | - |
crisitem.author.parentorg | IU de Estudios Ambientales y Recursos Naturales | - |
crisitem.author.parentorg | Departamento de Química | - |
crisitem.author.parentorg | Departamento de Química | - |
crisitem.author.parentorg | IU de Estudios Ambientales y Recursos Naturales | - |
crisitem.author.fullName | Herrera Melián, José Alberto | - |
crisitem.author.fullName | Hernández Brito, José Joaquín | - |
crisitem.author.fullName | Gelado Caballero, María Dolores | - |
crisitem.author.fullName | Pérez Peña,Jesús | - |
Colección: | Artículos |
Citas SCOPUSTM
15
actualizado el 30-mar-2025
Citas de WEB OF SCIENCETM
Citations
17
actualizado el 30-mar-2025
Visitas
66
actualizado el 13-jul-2024
Google ScholarTM
Verifica
Altmetric
Comparte
Exporta metadatos
Los elementos en ULPGC accedaCRIS están protegidos por derechos de autor con todos los derechos reservados, a menos que se indique lo contrario.