Identificador persistente para citar o vincular este elemento:
http://hdl.handle.net/10553/46307
Título: | Detoxification of waters contaminated with phenol, formaldehyde and phenol-formaldehyde mixtures using a combination of biological treatments and advanced oxidation techniques | Autores/as: | Ortega-Méndez, J. A. Melián, J. A.Herrera Araña, J. Doña Rodríguez, José Miguel Díaz, O. González Pérez Peña, Jesús |
Clasificación UNESCO: | 330811 Control de la contaminación del agua | Palabras clave: | Detoxification Phenol Oxidation techniques |
Fecha de publicación: | 2015 | Editor/a: | 0926-3373 | Proyectos: | Sistema Completo de Caracterización de la Relación Entre Composición, Estructura y Fotoactividad de Sólidos Sintéticos Con Aplicaciones Fotocatalíticas. | Publicación seriada: | Applied Catalysis B: Environmental | Resumen: | The detoxification process of waters contaminated with phenol, formaldehyde and phenol–formaldehyde mixtures was studied using advanced oxidation treatments (heterogeneous photocatalysis and Fenton), biological techniques (aerated biological and wetland reactors) and combinations of the two. It is shown that photocatalysis was efficient in the detoxification of concentrations below 50 mg L−1 of those compounds. Sample toxicity increased at higher concentrations due to the generated intermediates. Phenol–formaldehyde mixtures were impossible to detoxify by heterogeneous photocatalysis at any of the studied concentrations. Treatments using the Fenton reaction were able to degrade concentrations above 1000 mg L−1, though the use of a reagent such as peroxide makes it a costly technique. The efficiency of the biological aerated filter (BAF) mainly depended on initial concentration and toxicity, with removal rates of 3.08 and 0.26 g L−1 d−1 obtained for phenol and formaldehyde, respectively. Taking into account the results obtained for the treatment of complex phenol–formaldehyde mixtures, the best combination of techniques for the treatment of concentrations found in the industrial wastewater studied in this paper was the Fenton + BAF technique which was able to detoxify phenol–formaldehyde concentrations (1:1) of 1000 mg L−1. | URI: | http://hdl.handle.net/10553/46307 | ISSN: | 0926-3373 | DOI: | 10.1016/j.apcatb.2014.07.032 | Fuente: | Applied Catalysis B: Environmental [ISSN 0926-3373], v. 163, p. 63-73 |
Colección: | Artículos |
Citas SCOPUSTM
54
actualizado el 17-nov-2024
Citas de WEB OF SCIENCETM
Citations
53
actualizado el 17-nov-2024
Visitas
52
actualizado el 31-mar-2024
Google ScholarTM
Verifica
Altmetric
Comparte
Exporta metadatos
Los elementos en ULPGC accedaCRIS están protegidos por derechos de autor con todos los derechos reservados, a menos que se indique lo contrario.