Identificador persistente para citar o vincular este elemento: http://hdl.handle.net/10553/45808
Título: Simplified solid-phase extraction procedure combined with liquid chromatography tandem-mass spectrometry for multiresidue assessment of pharmaceutical compounds in environmental liquid samples
Autores/as: Afonso-Olivares, C. 
Čadková, T.
Sosa-Ferrera, Z. 
Santana-Rodríguez, J. J. 
Nováková, L.
Clasificación UNESCO: 32 Ciencias médicas
3308 Ingeniería y tecnología del medio ambiente
3209 Farmacología
Palabras clave: Pharmaceuticals
Wastewater
Simplified solid-phase extraction
High-performance liquid
Chromatography-tandem mass, et al.
Fecha de publicación: 2017
Publicación seriada: Journal of Chromatography A 
Resumen: To follow the twelve "green analytical chemistry" (GAC) principles, it is necessary to continuously develop analytical extraction and determination methodologies to assess the presence of micropollutants, such as pharmaceuticals, in environmental samples. A reduction in the analysis time and solvent quantity, which is one of the GAC principles, has been achieved through a simplified solid-phase extraction (SPE) procedure combined with high-performance liquid chromatography-tandem mass spectrometry (LC-MS/MS) for the determination of twenty-three pharmaceuticals in liquid environmental samples using N-vinylpyrrolidone-divinylbenzene copolymer (OASIS HLB) cartridges. The optimal SPE conditions were studied. In these optimized conditions, 82.6% of the data have a median recovery above 70% for all compounds in each sample. The relative standard deviations (RSDs) were below 14.4% and 22.0% for intra-and inter-day repeatability, respectively. Method detection limits (MDLs) and method quantification limits (MQLs) ranged from 0.011 to 188 ng L-1 and from 0.033 to 628 ng L-1, respectively. The applicability of the method was evaluated in real samples from natural and conventional wastewater treatment plants (WWTPs), and results were obtained in concentration ranges from 0.013 to 91.5 mu g L-1 and from 0.004 to 49.1 mu g L-1, respectively.
URI: http://hdl.handle.net/10553/35746
ISSN: 0021-9673
DOI: 10.1016/j.chroma.2017.01.059
Fuente: Journal of Chromatography A [ISSN 0021-9673], v. 1487, p. 54-63
Colección:Artículos
Vista completa

Citas SCOPUSTM   

21
actualizado el 21-abr-2024

Citas de WEB OF SCIENCETM
Citations

9
actualizado el 09-may-2021

Visitas

69
actualizado el 02-mar-2024

Google ScholarTM

Verifica

Altmetric


Comparte



Exporta metadatos



Los elementos en ULPGC accedaCRIS están protegidos por derechos de autor con todos los derechos reservados, a menos que se indique lo contrario.