Identificador persistente para citar o vincular este elemento:
http://hdl.handle.net/10553/45333
Campo DC | Valor | idioma |
---|---|---|
dc.contributor.author | González-Antuña, Ana | en_US |
dc.contributor.author | Rodríguez-González, Pablo | en_US |
dc.contributor.author | Lavandera, Iván | en_US |
dc.contributor.author | Centineo, Giuseppe | en_US |
dc.contributor.author | Gotor, Vicente | en_US |
dc.contributor.author | García Alonso, J. Ignacio | en_US |
dc.date.accessioned | 2018-11-22T09:01:21Z | - |
dc.date.available | 2018-11-22T09:01:21Z | - |
dc.date.issued | 2012 | en_US |
dc.identifier.issn | 1618-2642 | en_US |
dc.identifier.uri | http://hdl.handle.net/10553/45333 | - |
dc.description.abstract | A novel and fast routine method for the simultaneous determination and confirmation of clenbuterol in bovine and human urine samples by gas chromatography electron ionization mass spectrometry (GC-EI-MS) has been developed. The method employs isotope dilution mass spectrometry (IDMS) and is based on a combination of minimal labeling (a single (13)C label in the molecule) and isotope pattern deconvolution (IPD). This new methodology does not require the construction of a methodological calibration graph, and was compared with the classical IDMS procedure employed in clenbuterol analysis based on the use of a deuterated compound as internal standard (d(9)-clenbuterol) and a calibration curve. The sample preparation consists of simple extraction with dichloromethane, which was dried and derivatized with chloro(chloromethyl)dimethylsilane, generating a cyclic dimethylsilamorpholine (DMS) derivative suitable for GC(EI)MS detection and identification. This compound produces five intense ions in the electron ionization source, which allow the presence of clenbuterol to be confirmed in just one analysis, as demanded by European Union directives. The accuracy of the method was studied by performing recovery experiments at different concentration levels (from 0.3 to 5 ng g(-1)) in 5 mL bovine urine samples using two labeled compounds: an in-house-synthesized (13)C(1)-clenbuterol and a commercially available d(9)-clenbuterol. The detection limit of the method in human urine was 0.050 ng g(-1) with a sample volume of 10 mL, and is thus suitable for antidoping control purposes. Finally, the (13)C(1)-clenbuterol standard was employed for the determination of clenbuterol in two reference materials, BCR-503 and BCR-504 (lyophilized bovine urine). The concentrations obtained were in agreement with the certified values, with a reproducibility of below 1% RSD. | en_US |
dc.language | eng | en_US |
dc.relation.ispartof | Analytical and Bioanalytical Chemistry | en_US |
dc.source | Analytical and Bioanalytical Chemistry [ISSN 1618-2642], v. 402, p. 1879-1888 (Febrero 2012) | en_US |
dc.subject | 32 Ciencias médicas | en_US |
dc.subject | 230103 Análisis cromatográfico | en_US |
dc.subject | 230110 Espectroscopia de masas | en_US |
dc.subject.other | Clenbuterol | en_US |
dc.subject.other | Minimal labeling | en_US |
dc.subject.other | Isotope dilution | en_US |
dc.subject.other | Food safety | en_US |
dc.subject.other | Doping control | en_US |
dc.title | Development of a routine method for the simultaneous confirmation and determination of clenbuterol in urine by minimal labeling isotope pattern deconvolution and GC-EI-MS | en_US |
dc.type | info:eu-repo/semantics/article | en_US |
dc.type | Article | en_US |
dc.identifier.doi | 10.1007/s00216-011-5611-1 | en_US |
dc.identifier.scopus | 84858698239 | - |
dc.contributor.authorscopusid | 36058862700 | - |
dc.contributor.authorscopusid | 6603228633 | - |
dc.contributor.authorscopusid | 6505871917 | - |
dc.contributor.authorscopusid | 35557054000 | - |
dc.contributor.authorscopusid | 7005873573 | - |
dc.contributor.authorscopusid | 7005508838 | - |
dc.description.lastpage | 1888 | en_US |
dc.description.firstpage | 1879 | en_US |
dc.relation.volume | 402 | en_US |
dc.investigacion | Ciencias de la Salud | en_US |
dc.type2 | Artículo | en_US |
dc.description.numberofpages | 10 | en_US |
dc.utils.revision | Sí | en_US |
dc.date.coverdate | Febrero 2012 | en_US |
dc.identifier.ulpgc | Sí | en_US |
dc.contributor.buulpgc | BU-MED | en_US |
dc.description.sjr | 1,347 | |
dc.description.jcr | 3,659 | |
dc.description.sjrq | Q1 | |
dc.description.jcrq | Q1 | |
dc.description.scie | SCIE | |
item.grantfulltext | none | - |
item.fulltext | Sin texto completo | - |
crisitem.author.fullName | González Antuña, Ana | - |
Colección: | Artículos |
Citas SCOPUSTM
25
actualizado el 17-nov-2024
Citas de WEB OF SCIENCETM
Citations
23
actualizado el 17-nov-2024
Visitas
47
actualizado el 24-feb-2024
Google ScholarTM
Verifica
Altmetric
Comparte
Exporta metadatos
Los elementos en ULPGC accedaCRIS están protegidos por derechos de autor con todos los derechos reservados, a menos que se indique lo contrario.