Identificador persistente para citar o vincular este elemento:
http://hdl.handle.net/10553/44898
Campo DC | Valor | idioma |
---|---|---|
dc.contributor.author | Casals, Isidre | en_US |
dc.contributor.author | Reixach, Maria | en_US |
dc.contributor.author | Amat, Judith | en_US |
dc.contributor.author | Fuentes, Margarita | en_US |
dc.contributor.author | Serra-Majem, Lluís | en_US |
dc.date.accessioned | 2018-11-22T03:28:27Z | - |
dc.date.available | 2018-11-22T03:28:27Z | - |
dc.date.issued | 1996 | en_US |
dc.identifier.issn | 0021-9673 | en_US |
dc.identifier.uri | http://hdl.handle.net/10553/44898 | - |
dc.description.abstract | An HPLC isocratic method with pre-column derivatization and UV detection for the quantification of cyclamate and cyclohexylamine in urine samples is described. The method requires very little sample preparation. Free cyclohexylamine is analysed in a first run and subsequently cyclamate is analysed as cyclohexylamine, after the simple process of oxidation of the sample by means of hydrogen peroxide. Cycloheptylamine is used as internal standard. Trinitrobenzenesulfonic acid (TNBS) appears to be a good reagent for the pre-column derivatization. The time per run is 15 min; the coefficients of variation of the assays range from 1.1 to 5.5%; the limits of detection are 0.09 and 0.11 ppm for cyclohexylamine and cyclamate anion, respectively. The system described has always performed efficiently, with a high degree of stability, in daily routine work. | en_US |
dc.language | eng | en_US |
dc.relation.ispartof | Journal of Chromatography A | en_US |
dc.source | Journal of Chromatography A [ISSN 0021-9673], v. 750, p. 397-402 | en_US |
dc.subject | 32 Ciencias médicas | en_US |
dc.subject | 3212 Salud pública | en_US |
dc.subject | 230103 Análisis cromatográfico | en_US |
dc.subject.other | Cyclamate | en_US |
dc.subject.other | Cyclohexylamine | en_US |
dc.subject.other | Trinitrobenzenesulfonic acid | en_US |
dc.subject.other | Derivatization, LC | en_US |
dc.title | Quantification of cyclamate and cyclohexylamine in urine samples using high-performance liquid chromatography with trinitrobenzenesulfonic acid pre-column derivatization | en_US |
dc.type | info:eu-repo/semantics/article | en_US |
dc.type | Article | en_US |
dc.identifier.doi | 10.1016/0021-9673(96)00529-8 | en_US |
dc.identifier.scopus | 0030601519 | - |
dc.contributor.authorscopusid | 6602819319 | - |
dc.contributor.authorscopusid | 6507575436 | - |
dc.contributor.authorscopusid | 56681889200 | - |
dc.contributor.authorscopusid | 35569908400 | - |
dc.contributor.authorscopusid | 35596972100 | - |
dc.description.lastpage | 402 | en_US |
dc.description.firstpage | 397 | en_US |
dc.relation.volume | 750 | en_US |
dc.investigacion | Ciencias de la Salud | en_US |
dc.type2 | Artículo | en_US |
dc.description.numberofpages | 6 | en_US |
dc.utils.revision | Sí | en_US |
dc.date.coverdate | Octubre 1996 | en_US |
dc.identifier.ulpgc | Sí | en_US |
dc.contributor.buulpgc | BU-MED | en_US |
dc.description.scie | SCIE | |
item.fulltext | Sin texto completo | - |
item.grantfulltext | none | - |
crisitem.author.dept | GIR IUIBS: Nutrición | - |
crisitem.author.dept | IU de Investigaciones Biomédicas y Sanitarias | - |
crisitem.author.dept | Departamento de Ciencias Clínicas | - |
crisitem.author.orcid | 0000-0002-9658-9061 | - |
crisitem.author.parentorg | IU de Investigaciones Biomédicas y Sanitarias | - |
crisitem.author.fullName | Serra Majem, Luis | - |
Colección: | Artículos |
Citas SCOPUSTM
35
actualizado el 17-nov-2024
Citas de WEB OF SCIENCETM
Citations
29
actualizado el 17-nov-2024
Visitas
38
actualizado el 16-sep-2023
Google ScholarTM
Verifica
Altmetric
Comparte
Exporta metadatos
Los elementos en ULPGC accedaCRIS están protegidos por derechos de autor con todos los derechos reservados, a menos que se indique lo contrario.