Identificador persistente para citar o vincular este elemento:
http://hdl.handle.net/10553/44328
Campo DC | Valor | idioma |
---|---|---|
dc.contributor.author | Monzón-Verona, José Miguel | en_US |
dc.contributor.author | Santana-Martín, Francisco Jorge | en_US |
dc.contributor.author | Garcia-Alonso Montoya, Santiago | en_US |
dc.contributor.author | Montiel-Nelson, Juan Antonio | en_US |
dc.contributor.other | Montiel-Nelson, Juan | - |
dc.date.accessioned | 2018-11-21T22:05:07Z | - |
dc.date.available | 2018-11-21T22:05:07Z | - |
dc.date.issued | 2010 | en_US |
dc.identifier.issn | 1424-8220 | en_US |
dc.identifier.uri | http://hdl.handle.net/10553/44328 | - |
dc.description.abstract | An electro-quasistatic analysis of an induction micromotor has been realized by using the Cell Method. We employed the direct Finite Formulation (FF) of the electromagnetic laws, hence, avoiding a further discretization. The Cell Method (CM) is used for solving the field equations at the entire domain (2D space) of the micromotor. We have reformulated the field laws in a direct FF and analyzed physical quantities to make explicit the relationship between magnitudes and laws. We applied a primal-dual barycentric discretization of the 2D space. The electric potential has been calculated on each node of the primal mesh using CM. For verification purpose, an analytical electric potential equation is introduced as reference. In frequency domain, results demonstrate the error in calculating potential quantity is neglected (<3‰). In time domain, the potential value in transient state tends to the steady state value. | en_US |
dc.language | eng | en_US |
dc.publisher | 1424-8220 | - |
dc.relation.ispartof | Sensors | en_US |
dc.source | Sensors (Switzerland)[ISSN 1424-8220],v. 10, p. 9102-9117 | en_US |
dc.subject | 3306 Ingeniería y tecnología eléctricas | en_US |
dc.subject.other | Micromotor | en_US |
dc.subject.other | Electrostatic | en_US |
dc.subject.other | Induction | en_US |
dc.subject.other | Cell method | en_US |
dc.subject.other | Direct finite formulation | en_US |
dc.title | Electro-quasistatic analysis of an electrostatic induction micromotor using the cell method | en_US |
dc.type | info:eu-repo/semantics/Article | en_US |
dc.type | Article | en_US |
dc.identifier.doi | 10.3390/s101009102 | en_US |
dc.identifier.scopus | 84871075849 | - |
dc.identifier.isi | 000283581100018 | - |
dcterms.isPartOf | Sensors | - |
dcterms.source | Sensors[ISSN 1424-8220],v. 10 (10), p. 9102-9117 | - |
dc.contributor.authorscopusid | 26531597500 | - |
dc.contributor.authorscopusid | 26531766200 | - |
dc.contributor.authorscopusid | 35106946100 | - |
dc.contributor.authorscopusid | 6603626866 | - |
dc.description.lastpage | 9117 | en_US |
dc.description.firstpage | 9102 | en_US |
dc.relation.volume | 10 | en_US |
dc.investigacion | Ingeniería y Arquitectura | en_US |
dc.type2 | Artículo | en_US |
dc.identifier.wos | WOS:000283581100018 | - |
dc.contributor.daisngid | 5659103 | - |
dc.contributor.daisngid | 8865392 | - |
dc.contributor.daisngid | 3654087 | - |
dc.contributor.daisngid | 480589 | - |
dc.identifier.investigatorRID | K-6805-2013 | - |
dc.utils.revision | Sí | en_US |
dc.contributor.wosstandard | WOS:Monzon-Verona, JM | - |
dc.contributor.wosstandard | WOS:Santana-Martin, FJ | - |
dc.contributor.wosstandard | WOS:Garcia-Alonso, S | - |
dc.contributor.wosstandard | WOS:Montiel-Nelson, JA | - |
dc.date.coverdate | Octubre 2010 | en_US |
dc.identifier.ulpgc | Sí | en_US |
dc.contributor.buulpgc | BU-TEL | en_US |
dc.description.jcr | 1,774 | |
dc.description.jcrq | Q3 | |
dc.description.scie | SCIE | |
item.grantfulltext | open | - |
item.fulltext | Con texto completo | - |
crisitem.author.dept | GIR IUMA: Instrumentación avanzada | - |
crisitem.author.dept | IU de Microelectrónica Aplicada | - |
crisitem.author.dept | Departamento de Ingeniería Eléctrica | - |
crisitem.author.dept | GIR IUMA: Instrumentación avanzada | - |
crisitem.author.dept | IU de Microelectrónica Aplicada | - |
crisitem.author.dept | Departamento de Ingeniería Electrónica y Automática | - |
crisitem.author.dept | GIR IUMA: Instrumentación avanzada | - |
crisitem.author.dept | IU de Microelectrónica Aplicada | - |
crisitem.author.dept | Departamento de Ingeniería Electrónica y Automática | - |
crisitem.author.orcid | 0000-0001-9694-269X | - |
crisitem.author.orcid | 0000-0003-4389-0632 | - |
crisitem.author.orcid | 0000-0003-4323-8097 | - |
crisitem.author.parentorg | IU de Microelectrónica Aplicada | - |
crisitem.author.parentorg | IU de Microelectrónica Aplicada | - |
crisitem.author.parentorg | IU de Microelectrónica Aplicada | - |
crisitem.author.fullName | Monzón Verona, José Miguel | - |
crisitem.author.fullName | Garcia-Alonso Montoya, Santiago | - |
crisitem.author.fullName | Montiel Nelson, Juan Antonio | - |
Colección: | Artículos |
Vista resumida
Citas SCOPUSTM
4
actualizado el 17-nov-2024
Citas de WEB OF SCIENCETM
Citations
4
actualizado el 17-nov-2024
Visitas
103
actualizado el 09-mar-2024
Descargas
240
actualizado el 09-mar-2024
Google ScholarTM
Verifica
Altmetric
Comparte
Exporta metadatos
Los elementos en ULPGC accedaCRIS están protegidos por derechos de autor con todos los derechos reservados, a menos que se indique lo contrario.