Identificador persistente para citar o vincular este elemento:
http://hdl.handle.net/10553/44176
Campo DC | Valor | idioma |
---|---|---|
dc.contributor.author | Khoshgoftar Manesh, M. H. | en_US |
dc.contributor.author | Navid, P. | en_US |
dc.contributor.author | Baghestani, M. | en_US |
dc.contributor.author | Khamis Abadi, S. | en_US |
dc.contributor.author | Rosen, M. A. | en_US |
dc.contributor.author | Blanco Marigorta, Ana María | en_US |
dc.contributor.author | Amidpour, M. | en_US |
dc.contributor.other | Amidpour, Majid | - |
dc.contributor.other | Blanco-Marigorta, Ana M. | - |
dc.date.accessioned | 2018-11-21T20:48:32Z | - |
dc.date.available | 2018-11-21T20:48:32Z | - |
dc.date.issued | 2014 | en_US |
dc.identifier.issn | 0196-8904 | en_US |
dc.identifier.uri | http://hdl.handle.net/10553/44176 | - |
dc.description.abstract | The purpose of a steam power plant usually is electrical power generation; however, it can work as dual purpose plant producing steam and power simultaneously. In this paper we seek the optimum integration of a steam power plant as a source and a site utility system as a sink of steam and power. Estimating the cogeneration potential prior to the design of a central utility system for site utility systems is important for setting targets for site fuel demand as well as heat and power production. In this regard, an accurate cogeneration targeting procedure is used for the coupling of a steam power plant and a site utility consisting of a process plant. Exergoeconomic and exergoenvironmental evaluations are performed. In the exergoenvironmental analysis, the environmental impacts obtained by life cycle assessment (LCA) are apportioned to the exergy streams, identifying the main system components with the highest environmental impacts and possible improvements associated with these components. Moreover, exergoenvironmental variables are calculated, and an exergoenvironmental evaluation is carried out. In addition, the cogeneration targeting method has been applied. A gas fired steam power plant and a process site utility are considered as a case study, with the integration of steam levels of the steam power plant and the site utility system carried out using the new procedure presented in this paper. | en_US |
dc.language | eng | en_US |
dc.publisher | 0196-8904 | - |
dc.relation.ispartof | Energy Conversion and Management | en_US |
dc.source | Energy Conversion and Management [ISSN 0196-8904], v. 77, p. 469-483 | en_US |
dc.subject | 330306 Tecnología de la combustión | en_US |
dc.subject | 2391 Química ambiental | en_US |
dc.subject | 330311 Química industrial | en_US |
dc.subject.other | Cogeneration | en_US |
dc.subject.other | Exergoeconomic analysis | en_US |
dc.subject.other | Exergoenvironmental analysis | en_US |
dc.subject.other | Exergy | en_US |
dc.subject.other | Integration | en_US |
dc.subject.other | Steam power plant | en_US |
dc.title | Exergoeconomic and exergoenvironmental evaluation of the coupling of a gas fired steam power plant with a total site utility system | en_US |
dc.type | info:eu-repo/semantics/Article | es |
dc.type | Article | es |
dc.identifier.doi | 10.1016/j.enconman.2013.09.053 | |
dc.identifier.scopus | 84887047183 | - |
dc.identifier.isi | 000330494600052 | - |
dcterms.isPartOf | Energy Conversion And Management | - |
dcterms.source | Energy Conversion And Management[ISSN 0196-8904],v. 77, p. 469-483 | - |
dc.contributor.authorscopusid | 34876845000 | - |
dc.contributor.authorscopusid | 55555034900 | - |
dc.contributor.authorscopusid | 56816811500 | - |
dc.contributor.authorscopusid | 55619726700 | - |
dc.contributor.authorscopusid | 7401477722 | - |
dc.contributor.authorscopusid | 25652860100 | - |
dc.contributor.authorscopusid | 20733433700 | - |
dc.description.lastpage | 483 | - |
dc.description.firstpage | 469 | - |
dc.relation.volume | 77 | - |
dc.investigacion | Ingeniería y Arquitectura | en_US |
dc.type2 | Artículo | en_US |
dc.identifier.wos | WOS:000330494600052 | - |
dc.contributor.daisngid | 1451798 | - |
dc.contributor.daisngid | 6584949 | - |
dc.contributor.daisngid | 9593645 | - |
dc.contributor.daisngid | 4178559 | - |
dc.contributor.daisngid | 9804 | - |
dc.contributor.daisngid | 2029240 | - |
dc.contributor.daisngid | 248589 | - |
dc.identifier.investigatorRID | M-3769-2013 | - |
dc.identifier.investigatorRID | I-5927-2012 | - |
dc.utils.revision | Sí | en_US |
dc.contributor.wosstandard | WOS:Manesh, MHK | |
dc.contributor.wosstandard | WOS:Navid, P | |
dc.contributor.wosstandard | WOS:Baghestani, M | |
dc.contributor.wosstandard | WOS:Abadi, SK | |
dc.contributor.wosstandard | WOS:Rosen, MA | |
dc.contributor.wosstandard | WOS:Blanco, AM | |
dc.contributor.wosstandard | WOS:Amidpour, M | |
dc.date.coverdate | Enero 2014 | |
dc.identifier.ulpgc | Sí | es |
dc.description.sjr | 1,854 | |
dc.description.jcr | 4,38 | |
dc.description.sjrq | Q1 | |
dc.description.jcrq | Q1 | |
dc.description.scie | SCIE | |
item.grantfulltext | none | - |
item.fulltext | Sin texto completo | - |
crisitem.author.dept | GIR Group for the Research on Renewable Energy Systems | - |
crisitem.author.dept | Departamento de Ingeniería de Procesos | - |
crisitem.author.orcid | 0000-0003-4635-7235 | - |
crisitem.author.parentorg | Departamento de Ingeniería Mecánica | - |
crisitem.author.fullName | Blanco Marigorta, Ana María | - |
Colección: | Artículos |
Citas SCOPUSTM
56
actualizado el 17-nov-2024
Citas de WEB OF SCIENCETM
Citations
57
actualizado el 17-nov-2024
Visitas
64
actualizado el 31-dic-2023
Google ScholarTM
Verifica
Altmetric
Comparte
Exporta metadatos
Los elementos en ULPGC accedaCRIS están protegidos por derechos de autor con todos los derechos reservados, a menos que se indique lo contrario.