dc.description.abstractThe increase of nonlinear loads in networks involves rises in harmonic currents, resulting in voltage distortion that can affect other sensitive loads. The series voltage compensators are the devices used to reduce voltage deformation in networks of nonnegligible impedance. The control technique of the series compensator is one factor which can improve the operation of the series compensator, in order to reduce voltage disturbances existing in the network. The control of devices controlled by PWM permits the use of classical linear strategies and nonlinear control. Initially, in the paper, the linear and discrete model of the voltage compensator is obtained by using an original linearisation method for systems controlled by PWM, which shows better behaviour than conventional methods. Then a control algorithm is developed in minimum time based on the linear model obtained. The control algorithm has been simulated and has subsequently been implemented in a laboratory prototype of the series compensator, giving very satisfactory results.en_US
dc.languageengen_US
dc.publisher1350-2352
dc.relation.ispartofIEE Proceedings: Electric Power Applicationsen_US
dc.sourceIEE Proceedings: Electric Power Applications [ISSN 1350-2352], v. 153, p. 337-342en_US
dc.subject120606 Ecuaciones integro-diferencialesen_US
dc.subject3306 Ingeniería y tecnología eléctricasen_US
dc.subject.otherPower harmonic filtersen_US
dc.subject.otherActive filtersen_US
dc.subject.otherNonlinear control systemsen_US
dc.subject.otherLinearisation techniquesen_US
dc.titleLinearisation method and control for series active power filter by means of pulse-width modulationen_US
dc.typeinfo:eu-repo/semantics/Articlees
dc.typeArticlees
dc.identifier.doi10.1049/ip-epa:20050217
dc.identifier.scopus33646556713-
dc.identifier.isi000237858600003
dc.contributor.authorscopusid24341941100-
dc.contributor.authorscopusid23392958400-
dc.contributor.authorscopusid35547093600-
dc.description.lastpage342-
dc.description.firstpage337-
dc.relation.volume153-
dc.investigacionIngeniería y Arquitecturaen_US
dc.type2Artículoen_US
dc.contributor.daisngid4574046
dc.contributor.daisngid4413114
dc.contributor.daisngid212001
dc.utils.revisionen_US
dc.contributor.wosstandardWOS:Ramos, A
dc.contributor.wosstandardWOS:Nuez, I
dc.contributor.wosstandardWOS:Feliu, V
dc.date.coverdateMayo 2006
dc.identifier.ulpgces
dc.description.jcr0,29
dc.description.jcrqQ4
item.grantfulltextnone-
item.fulltextSin texto completo-
crisitem.author.deptGIR IUNAT: Control analítico de fuentes medioambientales-
crisitem.author.deptIU de Estudios Ambientales y Recursos Naturales-
crisitem.author.deptDepartamento de Ingeniería de Procesos-
crisitem.author.deptGIR Energía, Corrosión, Residuos y Agua-
crisitem.author.deptDepartamento de Ingeniería Electrónica y Automática-
crisitem.author.orcid0000-0001-5759-4469-
crisitem.author.orcid0000-0001-6652-2360-
crisitem.author.parentorgIU de Estudios Ambientales y Recursos Naturales-
crisitem.author.parentorgDepartamento de Ingeniería Electrónica y Automática-
crisitem.author.fullNameRamos Martín, Alejandro-
crisitem.author.fullNameDe La Nuez Pestana, Ignacio Agustín-
Appears in Collections:Artículos
Show simple item record

SCOPUSTM   
Citations

9
checked on Oct 13, 2024

WEB OF SCIENCETM
Citations

2
checked on Oct 13, 2024

Page view(s)

62
checked on Dec 30, 2023

Google ScholarTM

Check

Altmetric


Share



Export metadata



Items in accedaCRIS are protected by copyright, with all rights reserved, unless otherwise indicated.