Identificador persistente para citar o vincular este elemento: http://hdl.handle.net/10553/43838
Campo DC Valoridioma
dc.contributor.authorGotor, Antonio Gómezen_US
dc.contributor.authorPérez Báez, Sebastián O.en_US
dc.contributor.authorRamos, Martín Alejandroen_US
dc.contributor.authorRuiz-García, A.en_US
dc.contributor.authorGonzález, Antonio Casañasen_US
dc.contributor.authorRuiz-Saavedra, E.en_US
dc.contributor.otherPerez Baez, Sebastian O.-
dc.contributor.otherRuiz Garcia, Alejandro-
dc.contributor.otherRamos, Alejandro-
dc.date.accessioned2018-11-21T18:13:19Z-
dc.date.available2018-11-21T18:13:19Z-
dc.date.issued2013en_US
dc.identifier.issn1944-3994en_US
dc.identifier.urihttp://hdl.handle.net/10553/43838-
dc.description.abstractThis study proposes a simple design method of the Reverse osmosis (RO) system in RO brackish water desalination plants. This method is based on the application of maximum available recovery without scaling of any of the compounds present in the water as silica, calcium carbonate, calcium sulfate, barium sulfate, strontium sulfate, and calcium fluoride, and membrane manufacturer design guidelines, and the plant production. Although the method was originally conceived for application to subterranean brackish waters in the Canary Islands, Spain (principally Gran Canaria, Fuerteventura and Tenerife), it can be extrapolated to other types of region and water treatable with RO systems. The required input data are the chemical composition of the feed water, pH, temperature, silt density index membrane manufacturer design guidelines, and the plant production. The programmed method then determines the design of the RO system. The method whose procedure is described graphically and analytically can be used as an aid in design optimization of RO brackish water desalination plants with acid-free pretreatment processes and only the use of scale inhibitor using spiral wound membranes. Practical applications are presented. The final results for different types of feed water and capacities are showed.en_US
dc.languageengen_US
dc.publisher1944-3994
dc.relation.ispartofDesalination and Water Treatmenten_US
dc.sourceDesalination and Water Treatment [ISSN 1944-3994], v. 51, p. 4790-4799en_US
dc.subject330806 Regeneración del aguaen_US
dc.subject.otherBrackish wateren_US
dc.subject.otherReverse osmosisen_US
dc.subject.otherDesalination plantsen_US
dc.subject.otherRO system designen_US
dc.titleA design method of the RO system in reverse osmosis brackish water desalination plants (procedure)en_US
dc.typeinfo:eu-repo/semantics/Articlees
dc.typeArticlees
dc.identifier.doi10.1080/19443994.2013.774136
dc.identifier.scopus84880962682-
dc.identifier.isi000322157700002-
dcterms.isPartOfDesalination And Water Treatment
dcterms.sourceDesalination And Water Treatment[ISSN 1944-3994],v. 51 (25-27), p. 4790-4799
dc.contributor.authorscopusid16198715500-
dc.contributor.authorscopusid6603157518-
dc.contributor.authorscopusid6506878715-
dc.contributor.authorscopusid24341941100-
dc.contributor.authorscopusid55749145800-
dc.contributor.authorscopusid7404584870-
dc.description.lastpage4799-
dc.description.firstpage4790-
dc.relation.volume51-
dc.investigacionIngeniería y Arquitecturaen_US
dc.type2Artículoen_US
dc.identifier.wosWOS:000322157700002-
dc.contributor.daisngid6664150-
dc.contributor.daisngid3105421-
dc.contributor.daisngid1240221-
dc.contributor.daisngid4574046-
dc.contributor.daisngid2368242-
dc.contributor.daisngid12982050-
dc.identifier.investigatorRIDP-5191-2015-
dc.identifier.investigatorRIDM-3697-2014-
dc.identifier.investigatorRIDH-4351-2015-
dc.utils.revisionen_US
dc.contributor.wosstandardWOS:Saavedra, ER
dc.contributor.wosstandardWOS:Gotor, AG
dc.contributor.wosstandardWOS:Baez, SOP
dc.contributor.wosstandardWOS:Martin, AR
dc.contributor.wosstandardWOS:Ruiz-Garcia, A
dc.contributor.wosstandardWOS:Gonzalez, AC
dc.date.coverdateEnero 2013
dc.identifier.ulpgces
dc.description.sjr0,409
dc.description.jcr0,987
dc.description.sjrqQ2
dc.description.jcrqQ3
dc.description.scieSCIE
item.grantfulltextopen-
item.fulltextCon texto completo-
crisitem.author.deptGIR IUNAT: Control analítico de fuentes medioambientales-
crisitem.author.deptIU de Estudios Ambientales y Recursos Naturales-
crisitem.author.deptGIR IUNAT: Control analítico de fuentes medioambientales-
crisitem.author.deptIU de Estudios Ambientales y Recursos Naturales-
crisitem.author.deptDepartamento de Ingeniería de Procesos-
crisitem.author.deptGIR Sistemas industriales de eficiciencia, instrumentación y protección-
crisitem.author.deptDepartamento de Ingeniería Electrónica y Automática-
crisitem.author.orcid0000-0003-3536-8481-
crisitem.author.orcid0000-0003-3536-8481-
crisitem.author.orcid0000-0002-6909-0759-
crisitem.author.orcid0000-0001-5759-4469-
crisitem.author.orcid0000-0002-5209-653X-
crisitem.author.parentorgIU de Estudios Ambientales y Recursos Naturales-
crisitem.author.parentorgIU de Estudios Ambientales y Recursos Naturales-
crisitem.author.parentorgDepartamento de Ingeniería Electrónica y Automática-
crisitem.author.fullNameGómez Gotor, Antonio-
crisitem.author.fullNameGómez Gotor, Antonio-
crisitem.author.fullNamePérez Báez,Sebastián Ovidio-
crisitem.author.fullNameRamos Martín, Alejandro-
crisitem.author.fullNameRuiz García, Alejandro-
Colección:Artículos
miniatura
pdf
Adobe PDF (65,79 kB)
Vista resumida

Citas SCOPUSTM   

7
actualizado el 14-abr-2024

Citas de WEB OF SCIENCETM
Citations

7
actualizado el 25-feb-2024

Visitas

93
actualizado el 23-ene-2024

Descargas

196
actualizado el 23-ene-2024

Google ScholarTM

Verifica

Altmetric


Comparte



Exporta metadatos



Los elementos en ULPGC accedaCRIS están protegidos por derechos de autor con todos los derechos reservados, a menos que se indique lo contrario.