Identificador persistente para citar o vincular este elemento: http://hdl.handle.net/10553/43837
Campo DC Valoridioma
dc.contributor.authorSaavedra, Enrique Ruizen_US
dc.contributor.authorGotor, Antonio Gómezen_US
dc.contributor.authorPérez Báez, Sebastián O.en_US
dc.contributor.authorRamos, Martín Alejandroen_US
dc.contributor.authorRuiz-García, A.en_US
dc.contributor.authorGonzález, Antonio Casañasen_US
dc.contributor.otherPerez Baez, Sebastian O.-
dc.contributor.otherRuiz Garcia, Alejandro-
dc.contributor.otherRamos, Alejandro-
dc.date.accessioned2018-11-21T18:12:51Z-
dc.date.available2018-11-21T18:12:51Z-
dc.date.issued2013en_US
dc.identifier.issn1944-3994en_US
dc.identifier.urihttp://hdl.handle.net/10553/43837-
dc.description.abstractThe reverse osmosis (RO) brackish water desalination plant described in this article has been operating without acid in the pretreatment and only using two types of antiscalants (this was the first experience of 40,000 operating hours in Canaries). This work describes the graphical evolution of all the daily operating information of the first five years. A study of the normalization and standardization of the information about the five years of the evolution of the plant for fixed feedwater conditions, operating pressure, and system recovery is shown too, so that the performance evaluation of the plant can be indicated correctly. Likewise, this article describes the graphic evolution of thse brine Langelier saturation index (real and theoric values). The conclusions of this study and the operating experience are intended to get a practical and optimum design method of RO brackish water desalination plants.en_US
dc.languageengen_US
dc.publisher1944-3994-
dc.relation.ispartofDesalination and Water Treatmenten_US
dc.sourceDesalination and Water Treatment [ISSN 1944-3994], v. 51(25-27), p. 4785-4789en_US
dc.subject330806 Regeneración del aguaen_US
dc.subject.otherBrackish wateren_US
dc.subject.otherReverse osmosisen_US
dc.subject.otherDesalination plantsen_US
dc.subject.otherNormalizationen_US
dc.subject.otherOperating dataen_US
dc.titleEvaluation of the five years operating data of a RO brackish water desalination plant in Las Palmas, Canary Islands, Spain: A historic caseen_US
dc.typeinfo:eu-repo/semantics/Articlees
dc.typeArticlees
dc.identifier.doi10.1080/19443994.2013.774135
dc.identifier.scopus84880939990-
dc.identifier.isi000322157700001-
dcterms.isPartOfDesalination And Water Treatment-
dcterms.sourceDesalination And Water Treatment[ISSN 1944-3994],v. 51 (25-27), p. 4785-4789-
dc.contributor.authorscopusid16198715500-
dc.contributor.authorscopusid6603157518-
dc.contributor.authorscopusid6506878715-
dc.contributor.authorscopusid24341941100-
dc.contributor.authorscopusid55749145800-
dc.contributor.authorscopusid7404584870-
dc.description.lastpage4789-
dc.description.firstpage4785-
dc.relation.volume51-
dc.investigacionIngeniería y Arquitecturaen_US
dc.type2Artículoen_US
dc.identifier.wosWOS:000322157700001-
dc.contributor.daisngid6664150-
dc.contributor.daisngid3105421-
dc.contributor.daisngid1240221-
dc.contributor.daisngid4574046-
dc.contributor.daisngid2368242-
dc.contributor.daisngid12982050-
dc.identifier.investigatorRIDP-5191-2015-
dc.identifier.investigatorRIDM-3697-2014-
dc.identifier.investigatorRIDH-4351-2015-
dc.utils.revisionen_US
dc.contributor.wosstandardWOS:Saavedra, ER
dc.contributor.wosstandardWOS:Gotor, AG
dc.contributor.wosstandardWOS:Baez, SOP
dc.contributor.wosstandardWOS:Martin, AR
dc.contributor.wosstandardWOS:Ruiz-Garcia, A
dc.contributor.wosstandardWOS:Gonzalez, AC
dc.date.coverdateEnero 2013
dc.identifier.ulpgces
dc.description.sjr0,409
dc.description.jcr0,987
dc.description.sjrqQ2
dc.description.jcrqQ3
dc.description.scieSCIE
item.grantfulltextnone-
item.fulltextSin texto completo-
crisitem.author.deptGIR IUNAT: Control analítico de fuentes medioambientales-
crisitem.author.deptIU de Estudios Ambientales y Recursos Naturales-
crisitem.author.deptGIR IUNAT: Control analítico de fuentes medioambientales-
crisitem.author.deptIU de Estudios Ambientales y Recursos Naturales-
crisitem.author.deptDepartamento de Ingeniería de Procesos-
crisitem.author.deptGIR Energía, Corrosión, Residuos y Agua-
crisitem.author.deptDepartamento de Ingeniería Electrónica y Automática-
crisitem.author.orcid0000-0003-3536-8481-
crisitem.author.orcid0000-0002-6909-0759-
crisitem.author.orcid0000-0001-5759-4469-
crisitem.author.orcid0000-0002-5209-653X-
crisitem.author.parentorgIU de Estudios Ambientales y Recursos Naturales-
crisitem.author.parentorgIU de Estudios Ambientales y Recursos Naturales-
crisitem.author.parentorgDepartamento de Ingeniería Electrónica y Automática-
crisitem.author.fullNameGómez Gotor, Antonio-
crisitem.author.fullNamePérez Báez,Sebastián Ovidio-
crisitem.author.fullNameRamos Martín, Alejandro-
crisitem.author.fullNameRuiz García, Alejandro-
Colección:Artículos
Vista resumida

Citas SCOPUSTM   

7
actualizado el 10-nov-2024

Citas de WEB OF SCIENCETM
Citations

7
actualizado el 10-nov-2024

Visitas

73
actualizado el 24-ene-2024

Google ScholarTM

Verifica

Altmetric


Comparte



Exporta metadatos



Los elementos en ULPGC accedaCRIS están protegidos por derechos de autor con todos los derechos reservados, a menos que se indique lo contrario.