Identificador persistente para citar o vincular este elemento: http://hdl.handle.net/10553/42542
Título: Fluorescent microbead-based immunoassay for anti-Erysipelothrix rhusiopathiae antibody detection in cetaceans
Autores/as: Melero, Mar
Giménez-Lirola, Luis G.
Rubio-Guerri, Consuelo
Crespo-Picazo, José Luis
Sierra Pulpillo, Eva María 
García-Párraga, Daniel
García-Peña, Francisco Javier
Arbelo, Manuel 
Álvaro, Teresa
Valls, Mónica
Sánchez-Vizcaíno, José Manuel
Clasificación UNESCO: 240119 Zoología marina
310903 Inmunología
Palabras clave: Antibodies
Cetaceans
Erysipelas
Erysipelothrix rhusiopathiae
Fluorescent microbeadbased immunoassay
Fecha de publicación: 2016
Publicación seriada: Diseases of Aquatic Organisms 
Resumen: A fluorescent microbead-based immunoassay (FMIA) for detection of anti-Erysipelothrix rhusiopathiae antibodies in pigs was adapted for use in cetaceans. The FMIA was validated and adjusted using serum samples from 10 vaccinated captive bottlenose dolphins Tursiops truncatus collected between 1 and 13 mo after immunization. The technique was then used to analyze specimens from 15 free-ranging cetaceans stranded alive on the Valencian Medi-terranean coast between 2006 and 2014: 11 striped dolphins Stenella coeruleoalba, 3 Risso's dolphins Grampus griseus and 1 bottlenose dolphin Tursiops truncatus. One of these wild animals was confirmed to have died from E. rhusiopathiae septicemia, but no anti-E. rhusiopathiae antibodies were detected in its serum, pericardial fluid or milk samples. Another free-ranging individual, which lacked any signs or lesions that might be indicative of E. rhusiopathiae infection, showed high fluorescence intensity similar to that measured in captive dolphins at 6-13 mo after vaccination. These results suggest that this animal underwent an E. rhusiopathiae infection several months before stranding. The findings in the present study suggest that FMIA can be useful for detecting anti-E. rhusiopathiae antibodies in cetaceans, and its application to free-ranging animals is particularly interesting because of the great value of these specimens. Furthermore, the FMIA can be multiplexed to allow the determination of up to 100 analytes per sample in a single well, thereby reducing the cost, time and sample volume needed.
URI: http://hdl.handle.net/10553/42542
ISSN: 0177-5103
DOI: 10.3354/dao02948
Fuente: Diseases of Aquatic Organisms [ISSN 0177-5103], v. 117 (3), p. 237-243
Colección:Artículos
miniatura
pdf
Adobe PDF (345,48 kB)
Vista completa

Citas SCOPUSTM   

4
actualizado el 10-nov-2024

Citas de WEB OF SCIENCETM
Citations

3
actualizado el 10-nov-2024

Visitas

55
actualizado el 16-sep-2023

Descargas

80
actualizado el 16-sep-2023

Google ScholarTM

Verifica

Altmetric


Comparte



Exporta metadatos



Los elementos en ULPGC accedaCRIS están protegidos por derechos de autor con todos los derechos reservados, a menos que se indique lo contrario.