Identificador persistente para citar o vincular este elemento: http://hdl.handle.net/10553/41933
Campo DC Valoridioma
dc.contributor.authorLópez Álvarez, J. M.en_US
dc.contributor.authorPérez Quevedo, O.en_US
dc.contributor.authorSantana Cabrera, L.en_US
dc.contributor.authorRodríguez Escot, C.en_US
dc.contributor.authorRamírez Lorenzo, T.en_US
dc.contributor.authorLimiñana Cañal, J. M.en_US
dc.contributor.authorLoro Ferrer, J. F.en_US
dc.date.accessioned2018-09-14T07:17:30Z-
dc.date.available2018-09-14T07:17:30Z-
dc.date.issued2018en_US
dc.identifier.issn1346-4523en_US
dc.identifier.urihttp://hdl.handle.net/10553/41933-
dc.description.abstractObjective:To measure the depth (D (p)) and diameter (D (m)) of the internal jugular vein (IJV), femoral vein (FV), and femoral artery (FA) in pediatric patients to evaluate the clinical implications. Methods: This study included 125 pediatric patients. All of them underwent bilateral ultrasound study of vessels and were classified into three groups based on anthropometric and demographic parameters. Results: Measured mean D p values were: 0.72 (0.34) cm for the FA, 0.79 (0.35) cm for the FV, and 0.77 (0.24) cm for the IJV. Mean antero-posterior D m values were: 0.37 (0.17) cm for the FA, 0.42 (0.22) cm for the FV, and 0.59 (0.23) cm for the IJV. D p and D m increased with age (A), weight (W), height (H), and body surface area (BSA). In the lower ranges of these variables, D p was similar for all three studied vessels (0.6–0.7 cm). In the higher ranges, femoral vessel D p values (1.1–1.2 cm) were larger than jugular ones (0.9 cm). Additionally, in these low ranges, IJV D m values were larger than femoral ones (0.45–0.50 vs. 0.25 cm). In the higher ranges, diameter values were similar (0.6–0.7 cm). Conclusions: In pediatric patients, major vessels can be located and their depth and diameter measured by vascular ultrasound. In younger patients, jugular and femoral vessels had similar depth values; in older ones, they had similar diameters. Ultrasound measurements in pediatric patients could facilitate the choice of the vessel to be cannulated, the catheter diameter, and the length of the needle to be used. Vascular canalization of IJV may be recommended as the first choice because of its low depth and large diameter.en_US
dc.languageengen_US
dc.publisher1346-4523
dc.relation.ispartofJournal of Medical Ultrasonicsen_US
dc.sourceJournal of Medical Ultrasonics [ISSN 1346-4523], v. 45 (3), p. 469-477en_US
dc.subject320110 Pediatríaen_US
dc.subject.otherInternal jugular veinen_US
dc.subject.otherFemoral veinen_US
dc.subject.otherFemoral arteryen_US
dc.subject.otherUltrasound measurementen_US
dc.subject.otherPediatric patientsen_US
dc.titleVascular ultrasound in pediatrics: utility and application of location and measurement of jugular and femoral vesselsen_US
dc.typeinfo:eu-repo/semantics/Articlees
dc.typeArticlees
dc.identifier.doi10.1007/s10396-017-0853-y
dc.identifier.scopus85038350470
dc.identifier.isi000436806900012-
dc.contributor.authorscopusid55808071950
dc.contributor.authorscopusid57214025214
dc.contributor.authorscopusid56034504500
dc.contributor.authorscopusid16242725600
dc.contributor.authorscopusid56594821400
dc.contributor.authorscopusid57198781047
dc.contributor.authorscopusid7004386478
dc.contributor.authorscopusid57199717167
dc.description.lastpage477-
dc.identifier.issue3-
dc.description.firstpage469-
dc.relation.volume45-
dc.investigacionCiencias de la Saluden_US
dc.type2Artículoen_US
dc.contributor.daisngid5512651
dc.contributor.daisngid4696253
dc.contributor.daisngid34918976
dc.contributor.daisngid7378289
dc.contributor.daisngid9197340
dc.contributor.daisngid2555805
dc.contributor.daisngid1607538
dc.contributor.wosstandardWOS:Alvarez, JML
dc.contributor.wosstandardWOS:Quevedo, OP
dc.contributor.wosstandardWOS:Cabrera, LS
dc.contributor.wosstandardWOS:Escot, CR
dc.contributor.wosstandardWOS:Lorenzo, TR
dc.contributor.wosstandardWOS:Canal, JML
dc.contributor.wosstandardWOS:Ferrer, JFL
dc.date.coverdateJulio 2018
dc.identifier.ulpgces
dc.description.sjr0,314
dc.description.jcr0,966
dc.description.sjrqQ3
dc.description.jcrqQ4
dc.description.scieSCIE
item.grantfulltextnone-
item.fulltextSin texto completo-
crisitem.author.deptGIR TIDES: Investigación en Turismo y Transporte-
crisitem.author.deptIU de Turismo y Desarrollo Económico Sostenible-
crisitem.author.deptDepartamento de Análisis Económico Aplicado-
crisitem.author.deptGIR IUIBS: Bioquímica-
crisitem.author.deptIU de Investigaciones Biomédicas y Sanitarias-
crisitem.author.deptDepartamento de Ciencias Clínicas-
crisitem.author.orcid0000-0002-2950-2405-
crisitem.author.orcid0000-0002-0517-8209-
crisitem.author.parentorgIU de Turismo y Desarrollo Económico Sostenible-
crisitem.author.parentorgIU de Investigaciones Biomédicas y Sanitarias-
crisitem.author.fullNameMartín Hernández, Juan Carlos-
crisitem.author.fullNameLoro Ferrer, Juan Francisco-
Colección:Artículos
Vista resumida

Citas SCOPUSTM   

5
actualizado el 14-abr-2024

Citas de WEB OF SCIENCETM
Citations

3
actualizado el 25-feb-2024

Visitas

36
actualizado el 16-sep-2023

Google ScholarTM

Verifica

Altmetric


Comparte



Exporta metadatos



Los elementos en ULPGC accedaCRIS están protegidos por derechos de autor con todos los derechos reservados, a menos que se indique lo contrario.