Identificador persistente para citar o vincular este elemento: http://hdl.handle.net/10553/35455
Campo DC Valoridioma
dc.contributor.authorYánez Santana, Alejandro-
dc.contributor.authorCuadrado, Alberto-
dc.contributor.authorMartel Fuentes, Óscar-
dc.contributor.authorGarcés, Gerardo L.-
dc.date.accessioned2018-04-19T11:27:28Z-
dc.date.available2018-04-19T11:27:28Z-
dc.date.issued2017-
dc.identifier.issn0020-1383-
dc.identifier.urihttp://hdl.handle.net/10553/35455-
dc.description.abstractIntroduction: Screw stripping is a common situation in fracture fixation, particularly in osteopenic bone treatment. Surgeons' perception of screw stripping is relatively poor and the real number of loose screws in every plate-screw construct is unknown. The biomechanical and clinical implications of the different possible screw-stripping situations are also unidentified. In this study, construct stiffness in different scenarios of stripped screws is investigated. Method: A bone surrogate comminuted osteoporotic fracture was fixed with four screws in both sides of the fracture gap in 75 specimens. In four groups, one or two screws closest or distal to the gap were over-tightened and left in place in one part of the construct and the remaining screws were tightened with 0.3 N m torque (four groups). In the fifth group (control), all the screws were tightened with 0.3 N m torque. Construct stiffness was tested in terms of compression, bending, and torsion for 1000 cycles. Results: When one or two screws closest to the gap were stripped, stiffness only decreased by, respectively, 5.7% or 7.6% under compression and 4.7% or 6.7% under bending; however, stiffness in torsion was 15.1% or 32%, respectively, lower than the initial stiffness. When a screw distal to the gap was stripped, the stiffness decreased by 28% under bending and 10% under compression; no change was noted under torsion. When two screws distal to the gap were stripped, the stiffness decreased by 11% in compression, collapsed under bending, and decreased by 8% under torsion. Conclusions: Position and number of stripped screws affect the biomechanical properties of a construct in different ways, depending on the acting forces.-
dc.languageeng-
dc.relation.ispartofInjury-
dc.sourceInjury [ISSN 0020-1383], v. 48 (S6), p. S54-S59-
dc.subject3314 Tecnología médica-
dc.subject.otherScrew stripping-
dc.subject.otherStiffness-
dc.subject.otherPlate-screw construct-
dc.titleInfluence of the number and position of stripped screws on plate-screw construct biomechanical properties-
dc.typeinfo:eu-repo/semantics/Article-
dc.typeArticlees
dc.identifier.doi10.1016/S0020-1383(17)30795-7
dc.identifier.scopus85034424292
dc.identifier.isi000415936500008
dc.contributor.authorscopusid56406565300
dc.contributor.authorscopusid56423836100
dc.contributor.authorscopusid7005588567
dc.contributor.authorscopusid15048342800
dc.identifier.eissn1879-0267-
dc.description.lastpageS59-
dc.identifier.issueS6-
dc.description.firstpageS54-
dc.relation.volume48-
dc.investigacionCiencias de la Salud-
dc.type2Artículo-
dc.contributor.daisngid34942581
dc.contributor.daisngid29471397
dc.contributor.daisngid3815560
dc.contributor.daisngid12629772
dc.contributor.wosstandardWOS:Garces, GL
dc.contributor.wosstandardWOS:Yanez, A
dc.contributor.wosstandardWOS:Cuadrado, A
dc.contributor.wosstandardWOS:Martel, O
dc.date.coverdateNoviembre 2017
dc.identifier.ulpgces
dc.description.sjr0,99
dc.description.jcr2,199
dc.description.sjrqQ1
dc.description.jcrqQ2
dc.description.scieSCIE
item.grantfulltextnone-
item.fulltextSin texto completo-
crisitem.author.deptGIR Biomaterials and Biomechanics Research Group-
crisitem.author.deptDepartamento de Ciencias Médicas y Quirúrgicas-
crisitem.author.deptGIR Biomaterials and Biomechanics Research Group-
crisitem.author.deptDepartamento de Ingeniería Mecánica-
crisitem.author.deptGIR Biomaterials and Biomechanics Research Group-
crisitem.author.deptDepartamento de Ingeniería Mecánica-
crisitem.author.deptGIR Biomaterials and Biomechanics Research Group-
crisitem.author.deptDepartamento de Ingeniería Mecánica-
crisitem.author.orcid0000-0003-4494-9077-
crisitem.author.orcid0000-0002-1736-552X-
crisitem.author.orcid0000-0002-8599-781X-
crisitem.author.orcid0000-0003-3806-5523-
crisitem.author.parentorgDepartamento de Ingeniería Mecánica-
crisitem.author.parentorgDepartamento de Ingeniería Mecánica-
crisitem.author.parentorgDepartamento de Ingeniería Mecánica-
crisitem.author.parentorgDepartamento de Ingeniería Mecánica-
crisitem.author.fullNameGarcés Martín, Gerardo-
crisitem.author.fullNameYánez Santana, Manuel Alejandro-
crisitem.author.fullNameCuadrado Hernández, Alberto Javier-
crisitem.author.fullNameMartel Fuentes, Oscar-
Colección:Artículos
Vista resumida

Citas SCOPUSTM   

2
actualizado el 13-oct-2024

Citas de WEB OF SCIENCETM
Citations

1
actualizado el 13-oct-2024

Visitas

63
actualizado el 18-may-2024

Google ScholarTM

Verifica

Altmetric


Comparte



Exporta metadatos



Los elementos en ULPGC accedaCRIS están protegidos por derechos de autor con todos los derechos reservados, a menos que se indique lo contrario.