Identificador persistente para citar o vincular este elemento: http://hdl.handle.net/10553/16830
Título: Application of genetic algorithms for the calibration of an air quality model and its validation using pollutant measures from the surroundings of an electric power plant
Autores/as: Oliver, Albert 
Rodríguez, Eduardo 
Ramírez Naranjo, Jabel Alejandro 
Clasificación UNESCO: 1206 Análisis numérico
1204 Geometría
2509 Metereología
250902 Contaminación atmosférica
250908 Micrometeorología, et al.
Palabras clave: Finite element method
Air quality
Genetic algorithms
Calibration
Validation, et al.
Fecha de publicación: 2015
Resumen: This work presents the calibration and validation of an air quality finite element model applied to emissions from a thermal power plant located in Gran Canaria. The calibration is performed using genetic algorithms. To calibrate and validate the model, the authors use empirical measures of pollutants concentrations from 4 stations located nearby the power plant; an hourly record per station during 3 days is available. Measures from 3 stations will be used to calibrate, while validation will use measures from the remaining station…
URI: http://hdl.handle.net/10553/16830
Fuente: Congreso de Métodos Numéricos en Ingeniería. -- Lisboa, Portugal Instituto Superior Técnico. -- June 29 - July 2, 2015
Derechos: by-nc-nd
Colección:Actas de congresos
miniatura
Presentación
Adobe PDF (2,6 MB)
miniatura
Abstract
Adobe PDF (51,26 kB)
Vista completa

Visitas

24
actualizado el 11-feb-2023

Descargas

15
actualizado el 11-feb-2023

Google ScholarTM

Verifica


Comparte



Exporta metadatos



Los elementos en ULPGC accedaCRIS están protegidos por derechos de autor con todos los derechos reservados, a menos que se indique lo contrario.