Título: Accurate identification of ALK positive lung carcinoma patients: novel FDA-cleared automated fluorescence in situ hybridization scanning system and ultrasensitive immunohistochemistry
Autores/as: Conde, Esther
Suárez-Gauthier, Ana
Benito, Amparo
Garrido, Pilar
García Campelo, Rosario
Biscuola, Michele
Paz Ares, Luis
Hardisson, David
de Castro, Javier
Camacho, M Carmen
Rodríguez Abreu, Delvys 
Abdulkader, Ihab
Ramirez, Josep
Reguart, Noemí
Salido, Marta
Pijuán, Lara
Arriola, Edurne
Sanz, Julián
Folgueras, Victoria
Villanueva, Noemí
Clasificación UNESCO: 32 Ciencias médicas
320101 Oncología
3209 Farmacología
Palabras clave: Lung cancer patients
Immunohistochemistry
In situ hybridization
Clinical trials
Fecha de publicación: 2014
Publicación seriada: PLoS ONE 
Resumen: Background: Based on the excellent results of the clinical trials with ALK-inhibitors, the importance of accurately identifying ALK positive lung cancer has never been greater. However, there are increasing number of recent publications addressing discordances between FISH and IHC. The controversy is further fuelled by the different regulatory approvals. This situation prompted us to investigate two ALK IHC antibodies (using a novel ultrasensitive detection-amplification kit) and an automated ALK FISH scanning system (FDA-cleared) in a series of non-small cell lung cancer tumor samples. Methods: Forty-seven ALK FISH-positive and 56 ALK FISH-negative NSCLC samples were studied. All specimens were screened for ALK expression by two IHC antibodies (clone 5A4 from Novocastra and clone D5F3 from Ventana) and for ALK rearrangement by FISH (Vysis ALK FISH break-apart kit), which was automatically captured and scored by using Bioview's automated scanning system. Results: All positive cases with the IHC antibodies were FISH-positive. There was only one IHC-negative case with both antibodies which showed a FISH-positive result. The overall sensitivity and specificity of the IHC in comparison with FISH were 98% and 100%, respectively. Conclusions: The specificity of these ultrasensitive IHC assays may obviate the need for FISH confirmation in positive IHC cases. However, the likelihood of false negative IHC results strengthens the case for FISH testing, at least in some situations
URI: https://accedacris.ulpgc.es/jspui/handle/10553/158959
ISSN: 1932-6203
DOI: 10.1371/journal.pone.0107200
Fuente: PLoS ONE, [ISSN 1932-6203], v.9 (9), p. 1-9, (2014).