Título: Clinical utility of targeted SARS-CoV-2 serology testing to aid the diagnosis and management of suspected missed, late or post-COVID-19 infection syndromes: Results from a pilot service implemented during the first pandemic wave
Autores/as: Sweeney, Nicola
Merrick, Blair
Pedro Galão, Rui
Pickering, Suzanne
Botgros, Alina
Wilson, Harry D.
Signell, Adrian W.
Betancor Quintana, Gilberto Jose 
Tan, Mark Kia Ik
Ramble, John
Kouphou, Neophytos
Acors, Sam
Graham, Carl
Seow, Jeffrey
MacMahon, Eithne
Neil, Stuart J. D.
Malim, Michael H.
Doores, Katie
Douthwaite, Sam
Batra, Rahul
Nebbia, Gaia
Edgeworth, Jonathan D.
Coordinadores/as, Directores/as o Editores/as: Nagler, Michael
Clasificación UNESCO: 32 Ciencias médicas
320505 Enfermedades infecciosas
Fecha de publicación: 2021
Publicación seriada: PLoS ONE 
Resumen: During the first wave of the global COVID-19 pandemic the clinical utility and indications for SARS-CoV-2 serological testing were not clearly defined. The urgency to deploy serological assays required rapid evaluation of their performance characteristics. We undertook an internal validation of a CE marked lateral flow immunoassay (LFIA) (SureScreen Diagnostics) using serum from SARS-CoV-2 RNA positive individuals and pre-pandemic samples. This was followed by the delivery of a same-day named patient SARS-CoV-2 serology service using LFIA on vetted referrals at central London teaching hospital with clinical interpretation of result provided to the direct care team. Assay performance, source and nature of referrals, feasibility and clinical utility of the service, particularly benefit in clinical decision-making, were recorded. Sensitivity and specificity of LFIA were 96.1% and 99.3% respectively. 113 tests were performed on 108 participants during three-week pilot. 44% participants (n = 48) had detectable antibodies. Three main indications were identified for serological testing; new acute presentations potentially triggered by recent COVID-19 e.g. pulmonary embolism (n = 5), potential missed diagnoses in context of a recent COVID-19 compatible illness (n = 40), and making infection control or immunosuppression management decisions in persistently SARS-CoV-2 RNA PCR positive individuals (n = 6). We demonstrate acceptable performance characteristics, feasibility and clinical utility of using a LFIA that detects anti-spike antibodies to deliver SARS-CoV-2 serology service in adults and children. Greatest benefit was seen where there is reasonable pre-test probability and results can be linked with clinical advice or intervention. Experience from this pilot can help inform practicalities and benefits of rapidly implementing new tests such as LFIAs into clinical service as the pandemic evolves.
URI: https://accedacris.ulpgc.es/jspui/handle/10553/156309
ISSN: 1932-6203
DOI: 10.1371/journal.pone.0249791
Fuente: PLoS ONE [eISSN 1932-6203], v. 16(4)
Colección:Artículos
Adobe PDF (1,26 MB)
Vista completa

Citas de WEB OF SCIENCETM
Citations

6
actualizado el 22-feb-2026

Google ScholarTM

Verifica

Altmetric


Comparte



Exporta metadatos



Los elementos en ULPGC accedaCRIS están protegidos por derechos de autor con todos los derechos reservados, a menos que se indique lo contrario.