Identificador persistente para citar o vincular este elemento: https://accedacris.ulpgc.es/jspui/handle/10553/153380
Campo DC Valoridioma
dc.contributor.authorVillasante-Marcos, V.en_US
dc.contributor.authorFinizola, A.en_US
dc.contributor.authorAbella, R.en_US
dc.contributor.authorBarde-Cabusson, S.en_US
dc.contributor.authorBlanco, M.J.en_US
dc.contributor.authorBrenes, B.en_US
dc.contributor.authorCabrera, V.en_US
dc.contributor.authorCasas, B.en_US
dc.contributor.authorDe Agustín, P.en_US
dc.contributor.authorDi Gangi, F.en_US
dc.contributor.authorDomínguez, I.en_US
dc.contributor.authorGarcía Pérez, Olayaen_US
dc.contributor.authorGomis, A.en_US
dc.contributor.authorGuzmán, J.en_US
dc.contributor.authorIribarren, I.en_US
dc.contributor.authorLevieux, G.en_US
dc.contributor.authorLópez, C.en_US
dc.contributor.authorLuengo-Oroz, N.en_US
dc.contributor.authorMartín, I.en_US
dc.contributor.authorMoreno, M.en_US
dc.contributor.authorMeletlidis, S.en_US
dc.contributor.authorMorin, J.en_US
dc.contributor.authorMoure, D.en_US
dc.contributor.authorPereda, J.en_US
dc.contributor.authorRicci, T.en_US
dc.contributor.authorRomero, E.en_US
dc.contributor.authorSchütze, C.en_US
dc.contributor.authorSuski-Ricci, B.en_US
dc.contributor.authorTorres, P.en_US
dc.contributor.authorTrigo, P.en_US
dc.date.accessioned2025-12-11T15:38:37Z-
dc.date.available2025-12-11T15:38:37Z-
dc.date.issued2014en_US
dc.identifier.issn0377-0273en_US
dc.identifier.urihttps://accedacris.ulpgc.es/jspui/handle/10553/153380-
dc.description.abstractAn extensive self-potential survey was carried out in the central volcanic complex of Tenerife Island (Canary Islands, Spain). A total amount of ~ 237 km of profiles with 20 m spacing between measurements was completed, including radial profiles extending from the summits of Teide and Pico Viejo, and circular profiles inside and around Las Cañadas caldera and the northern slopes of Teide and Pico Viejo. One of the main results of this mapping is the detection of well-developed hydrothermal systems within the edifices of Teide and Pico Viejo, and also associated with the flank satellite M. Blanca and M. Rajada volcanoes. A strong structural control of the surface manifestation of these hydrothermal systems is deduced from the data, pointing to the subdivision of Teide and Pico Viejo hydrothermal systems in three zones: summit crater, upper and lower hydrothermal systems. Self-potential maxima related to hydrothermal activity are absent from the proximal parts of the NE and NW rift zones as well as from at least two of the mafic historical eruptions (Chinyero and Siete Fuentes), indicating that long-lived hydrothermal systems have developed exclusively over relatively shallow felsic magma reservoirs. Towards Las Cañadas caldera floor and walls, the influence of the central hydrothermal systems disappears and the self-potential signal is controlled by the topography, the distance to the water table of Las Cañadas aquifer and its geometry. Nevertheless, fossil or remanent hydrothermal activity at some points along the Caldera wall, especially around the Roques de García area, is also suggested by the data. Self-potential data indicate the existence of independent groundwater systems in the three calderas of Ucanca, Guajara and Diego Hernández, with a funnel shaped negative anomaly in the Diego Hernández caldera floor related to the subsurface topography of the caldera bottom. Two other important self-potential features are detected: positive values towards the northwestern Santiago rift, possibly due to the relatively high altitude of the water-table in this area; and a linear set of minima to the west of Pico Viejo, aligned with the northwestern rift and related to meteoric water infiltration along its fracture system.en_US
dc.languageengen_US
dc.relation.ispartofJournal of Volcanology and Geothermal Researchen_US
dc.sourceJournal of Volcanology and Geothermal Research [ISSN 0377-0273], v. 272, p. 59-77en_US
dc.subject250621 Vulcanologíaen_US
dc.titleHydrothermal system of Central Tenerife Volcanic Complex, Canary Islands (Spain), inferred from self-potential measurementsen_US
dc.typeinfo:eu-repo/semantics/articleen_US
dc.typeArticleen_US
dc.identifier.doi10.1016/j.jvolgeores.2013.12.007en_US
dc.identifier.scopus2-s2.0-84893042269-
dc.contributor.orcid#NODATA#-
dc.contributor.orcid#NODATA#-
dc.contributor.orcid#NODATA#-
dc.contributor.orcid#NODATA#-
dc.contributor.orcid#NODATA#-
dc.contributor.orcid#NODATA#-
dc.contributor.orcid#NODATA#-
dc.contributor.orcid#NODATA#-
dc.contributor.orcid#NODATA#-
dc.contributor.orcid#NODATA#-
dc.contributor.orcid#NODATA#-
dc.contributor.orcid#NODATA#-
dc.contributor.orcid#NODATA#-
dc.contributor.orcid#NODATA#-
dc.contributor.orcid#NODATA#-
dc.contributor.orcid#NODATA#-
dc.contributor.orcid#NODATA#-
dc.contributor.orcid#NODATA#-
dc.contributor.orcid#NODATA#-
dc.contributor.orcid#NODATA#-
dc.contributor.orcid#NODATA#-
dc.contributor.orcid#NODATA#-
dc.contributor.orcid#NODATA#-
dc.contributor.orcid#NODATA#-
dc.contributor.orcid#NODATA#-
dc.contributor.orcid#NODATA#-
dc.contributor.orcid#NODATA#-
dc.contributor.orcid#NODATA#-
dc.contributor.orcid#NODATA#-
dc.contributor.orcid#NODATA#-
dc.description.lastpage77en_US
dc.description.firstpage59en_US
dc.relation.volume272en_US
dc.investigacionCienciasen_US
dc.type2Artículoen_US
dc.identifier.external198286324-
dc.description.numberofpages19en_US
dc.utils.revisionen_US
dc.date.coverdateFebrero 2014en_US
dc.identifier.ulpgcNoen_US
dc.contributor.buulpgcBU-BASen_US
dc.description.sjr1,723
dc.description.jcr2,543
dc.description.sjrqQ1
dc.description.jcrqQ2
dc.description.scieSCIE
item.fulltextCon texto completo-
item.grantfulltextopen-
crisitem.author.deptDepartamento de Física-
crisitem.author.orcid0009-0007-0184-7990-
crisitem.author.fullNameGarcía Pérez, Olaya-
Colección:Artículos
Adobe PDF (3,09 MB)
Vista resumida

Citas de WEB OF SCIENCETM
Citations

30
actualizado el 12-ene-2026

Visitas

43
actualizado el 15-ene-2026

Descargas

23
actualizado el 15-ene-2026

Google ScholarTM

Verifica

Altmetric


Comparte



Exporta metadatos



Los elementos en ULPGC accedaCRIS están protegidos por derechos de autor con todos los derechos reservados, a menos que se indique lo contrario.