Identificador persistente para citar o vincular este elemento: https://accedacris.ulpgc.es/jspui/handle/10553/147097
Campo DC Valoridioma
dc.contributor.authorHernández Gil, Marcos Javieren_US
dc.contributor.authorRamos-de-Miguel, D.en_US
dc.contributor.authorGreiner, D.en_US
dc.contributor.authorBenítez, A.en_US
dc.contributor.authorRamos Macías, J.M. Escobaren_US
dc.date.accessioned2025-09-16T06:31:21Z-
dc.date.available2025-09-16T06:31:21Z-
dc.date.issued2024en_US
dc.identifier.urihttps://accedacris.ulpgc.es/jspui/handle/10553/147097-
dc.description.abstractObjective: This presentation proposes a method for multipolar stimulation that aims to achieve the narrowest possible pattern of current densities at target neurons in cochlear implants. Multipolar stimulation results in increased power consumption due to the simultaneous generation of intracochlear currents by multiple electrodes. Our objective is to identify those electrode current profiles that maximize focusing while minimizing power consumption. Methods: We have developed two objective functions: one for focusing and the other for power dissipation in the electrolyte. They are evaluated using a finite element-based volume conduction model that replicates a cochlear geometry. Several conductivities of the model are adjusted to match the transimpedance matrix measured in a patient, using an inverse optimization procedure. Once the model is calibrated, we apply multi-objective optimization using evolutionary algorithms. Results: Computational results reveal non-dominated solutions (optimal from a multi-objective optimization perspective) corresponding to a cochlear geometry with perimodiolar insertion of the electrode array, including: 1) a solution demonstrating that the modeled current density at target neurons can achieve tighter focus than a phased-array stimulus, albeit with higher power consumption; 2) solutions that simultaneously improve the focusing and power consumption of the phased-array stimulus. Conclusions: We have successfully obtained solutions that enhance the focusing of phased-array stimulation and diminish its power consumption, offering advantageous current profiles stimulation compared to phased-array.en_US
dc.languageengen_US
dc.subject3314 Tecnología médicaen_US
dc.titleComputational simulation and optimization of multipolar stimulation in cochlear implantsen_US
dc.typeinfo:eu-repo/semantics/conferenceobjecten_US
dc.typeConferenceObjecten_US
dc.relation.conference17th International Conference on Cochlear Implants and other Implantable Technologies (CI2024)en_US
dc.investigacionIngeniería y Arquitecturaen_US
dc.type2Actas de congresosen_US
dc.utils.revisionen_US
dc.date.coverdate21-24 de Febrero de 2024en_US
dc.identifier.ulpgcen_US
dc.contributor.buulpgcBU-TELen_US
item.fulltextSin texto completo-
item.grantfulltextnone-
crisitem.author.deptGIR SIANI: Modelización y Simulación Computacional-
crisitem.author.deptIU Sistemas Inteligentes y Aplicaciones Numéricas-
crisitem.author.orcid0000-0001-9781-2811-
crisitem.author.parentorgIU Sistemas Inteligentes y Aplicaciones Numéricas-
crisitem.author.fullNameHernández Gil, Marcos Javier-
Colección:Actas de congresos
Vista resumida

Google ScholarTM

Verifica


Comparte



Exporta metadatos



Los elementos en ULPGC accedaCRIS están protegidos por derechos de autor con todos los derechos reservados, a menos que se indique lo contrario.