Please use this identifier to cite or link to this item: https://accedacris.ulpgc.es/handle/10553/137204
DC FieldValueLanguage
dc.contributor.authorSantillan Carranza, Holgeren_US
dc.contributor.authorEncalada, Gabrielen_US
dc.date.accessioned2025-04-24T07:24:19Z-
dc.date.available2025-04-24T07:24:19Z-
dc.date.issued2024en_US
dc.identifier.issn2449-5220en_US
dc.identifier.otherScopus-
dc.identifier.urihttps://accedacris.ulpgc.es/handle/10553/137204-
dc.description.abstractThe main objective of this research is to improve the reliability of the electrical system under study by reducing both the frequency of outages (SAIFI) and the downtime of electrical service (SAIDI). These problems are largely affected by adverse weather conditions, vegetation growth, and bird contact. To carry out the analysis, the 5011 urban feeder of Canton La Troncal was selected, since it presents critical values in terms of reliability compared to other feeders. The proposed methodology involves a mathematical model of heuristic optimization based on the Particle Swarm Optimization (PSO) algorithm. Two scenarios are defined for the modeling: the first focuses on relocating the existing recloser and the second on analyzing the impact of adding additional protection equipment. These scenarios are validated and demonstrate their effectiveness, achieving an improvement of 29.05% in the first case and 70.93% in the second case within a real conventional distribution system.en_US
dc.languageengen_US
dc.relation.ispartofDiagnostykaen_US
dc.sourceDiagnostyka [EISSN 2449-5220], v. 25 (3), (Enero 2024)en_US
dc.subject330609 Transmisión y distribuciónen_US
dc.subject.otherDistribution Systemen_US
dc.subject.otherParticle Swarm Algorithmen_US
dc.subject.otherRecloseren_US
dc.subject.otherReliabilityen_US
dc.subject.otherSaidien_US
dc.subject.otherSaifien_US
dc.titleRecloser optimization in electrical distribution systems using reliability analysis with heuristic algorithmen_US
dc.typeinfo:eu-repo/semantics/Articleen_US
dc.typeArticleen_US
dc.identifier.doi10.29354/diag/192183en_US
dc.identifier.scopus85203326480-
dc.contributor.orcid0000-0003-4803-7016-
dc.contributor.orcid0009-0004-9427-7314-
dc.contributor.authorscopusid58912483500-
dc.contributor.authorscopusid59317587400-
dc.identifier.eissn2449-5220-
dc.identifier.issue3-
dc.relation.volume25en_US
dc.investigacionIngeniería y Arquitecturaen_US
dc.type2Artículoen_US
dc.description.numberofpages11en_US
dc.utils.revisionen_US
dc.date.coverdateEnero 2024en_US
dc.identifier.ulpgcen_US
dc.contributor.buulpgcBU-TELen_US
dc.description.sjr0,265
dc.description.sjrqQ3
dc.description.miaricds9,8
item.fulltextCon texto completo-
item.grantfulltextopen-
crisitem.author.fullNameSantillan Carranza, Holger-
Appears in Collections:Artículos
Adobe PDF (904,61 kB)
Show simple item record

Google ScholarTM

Check

Altmetric


Share



Export metadata



Items in accedaCRIS are protected by copyright, with all rights reserved, unless otherwise indicated.