Please use this identifier to cite or link to this item: http://hdl.handle.net/10553/135310
Title: Intra and Inter-Test Reliability of Isometric Hip Adduction Strength Test with Force Plates in Professional Soccer Players
Authors: Perez Contreras, Jorge Edmundo 
Loro Ferrer, Juan Francisco 
Merino-Muñoz, Pablo
Hermosilla Palma, Felipe 
Miranda-Lorca, Brayan
Bustamante-Garrido, Alejandro
Inostroza-Ríos, Felipe
Brito, Ciro José
Aedo-Muñoz, Esteban
UNESCO Clasification: 32 Ciencias médicas
2411 Fisiología humana
Keywords: Hip
Isometric Contraction
Muscle Strength
Reproducibility
Issue Date: 2024
Journal: Journal of Functional Morphology and Kinesiology 
Abstract: Assessing the reliability of measurement instruments and equipment is essential to ensure the accurate tracking of athletes over extended periods, minimizing the measurement errors caused by chance or other factors. However, a less common but equally important analysis is the verification of inter-measurement agreement, which complements the reliability results. Purpose: To evaluate the intra- and inter-test reliability of an isometric hip adduction strength and asymmetries test in professional soccer players. Methods: Twenty-three professional male soccer players were evaluated on two occasions, 1 week apart. The force signal was collected using force plates (Pasco PS-2141), and the data processing was performed using Matlab software (R2023a, MathWorks, Natick, MA, USA). The peak force, interval RFD, peak RFD, peak force asymmetry and RFD were analyzed. Intraclass correlation coefficients (ICCs) and coefficients of variation (CV) were calculated to corroborate the intra- and inter-test reliability. In addition, the degree of agreement of the asymmetries was corroborated through the kappa index. Results: The peak force demonstrated an acceptable absolute reliability (CV < 10%) for the intra-test and test–retest condition, an excellent relative intra-test reliability and a good to moderate reliability for the test–retest reliability. However, the peak force asymmetry showed a moderate test–retest reliability and agreement. For the intra-test condition, the RFD variables demonstrate a moderate to excellent relative reliability; however, all demonstrate unacceptable absolute reliability (CV > 10%) in at least one of the evaluation sessions. A moderate to poor test–retest reliability and unacceptable absolute reliability were observed for all the RFD variables. Conclusions: The peak force is the variable with the highest intra- and inter-test reliability, so its use is recommended to longitudinally assess the maximum strength of the adductors in professional soccer players, but not the asymmetry orientation of the peak force. The RFD variables should be interpreted with caution due to their inconsistent reliability, and it is necessary to improve the methods used to achieve adequate reliability.
URI: http://hdl.handle.net/10553/135310
ISSN: 2411-5142
DOI: 10.3390/jfmk9040270
Source: Journal of Functional Morphology and Kinesiology[EISSN 2411-5142],v. 9 (4), (Diciembre 2024)
Appears in Collections:Artículos
Adobe PDF (1,61 MB)
Show full item record

Page view(s)

24
checked on Jan 18, 2025

Download(s)

8
checked on Jan 18, 2025

Google ScholarTM

Check

Altmetric


Share



Export metadata



Items in accedaCRIS are protected by copyright, with all rights reserved, unless otherwise indicated.