Please use this identifier to cite or link to this item: http://hdl.handle.net/10553/134497
DC FieldValueLanguage
dc.contributor.authorRosales Asensio, Enriqueen_US
dc.contributor.authorIcaza, Danielen_US
dc.contributor.authorGonzález Cobos, Noemíen_US
dc.contributor.authorBorges Díez, Daviden_US
dc.date.accessioned2024-10-22T16:57:49Z-
dc.date.available2024-10-22T16:57:49Z-
dc.date.issued2023en_US
dc.identifier.urihttp://hdl.handle.net/10553/134497-
dc.description.abstractThis research analyzes the combined peak reduction and resilience increase in critical buildings through the use of microgrids configured using a specific control system to provide correct power quality for local loads that can be either connected or disconnected from the grid, operating grid-connected or islanded mode. In case of grid failure, energy storage combined with one or several local generators can provide backup power and consider both conventional and renewable energy systems. This research focuses on the design of building energy systems that are able to maintain the energy supply and establishes a methodology to evaluate the resilience benefits of a microgrid integrated into critical buildings when power outages occur and the particular case of a hospital building is presented. The optimization of the dispatch and heating and cooling strategies are analyzed and a case study characterizing an electric polygeneration microgrid feeding critical loads is presented. Results show the benefits and the increased energy resilience achieved when using solar PV, electrochemical batteries, combined heat and power, TES water tanks, and absorption chillers and propose a design and optimization scheme that can be applied for similar buildings and extend to any facility with critical loads. Results show that these microgrids can be optimally designed to improve the resilience of critical energy systems and, simultaneously, achieve economic benefits. Results show that in the event of an outage the positive monetary effects last longer than the duration of the outage.en_US
dc.languageengen_US
dc.publisherSpringeren_US
dc.sourceJournal of Building Engineering [ISSN 2352-7102]en_US
dc.subjectInvestigaciónen_US
dc.subject.otherPeak load reductionen_US
dc.subject.otherResilience benefitsen_US
dc.subject.otherResilience analysisen_US
dc.subject.otherDispatch optimizationen_US
dc.subject.otherCritical microgridsen_US
dc.titlePeak load reduction and resilience benefits in critical microgridsen_US
dc.typeinfo:eu-repo/semantics/bookParten_US
dc.typeBookParten_US
dc.identifier.doidoi.org/10.1007/978-3-031-67754-0_6en_US
dc.description.lastpage16en_US
dc.description.firstpage1en_US
dc.investigacionIngeniería y Arquitecturaen_US
dc.type2Capítulo de libroen_US
dc.description.numberofpages16en_US
dc.utils.revisionen_US
dc.date.coverdate2023en_US
dc.identifier.ulpgcen_US
dc.identifier.ulpgcen_US
dc.identifier.ulpgcen_US
dc.identifier.ulpgcen_US
dc.contributor.buulpgcBU-INGen_US
dc.contributor.buulpgcBU-INGen_US
dc.contributor.buulpgcBU-INGen_US
dc.contributor.buulpgcBU-INGen_US
dc.description.spiqQ1
item.grantfulltextopen-
item.fulltextCon texto completo-
crisitem.author.deptGIR Group for the Research on Renewable Energy Systems-
crisitem.author.deptDepartamento de Ingeniería Eléctrica-
crisitem.author.orcid0000-0003-4112-5259-
crisitem.author.parentorgDepartamento de Ingeniería Mecánica-
crisitem.author.fullNameRosales Asensio, Enrique-
Appears in Collections:Capítulo de libro
Adobe PDF (7,14 MB)
Show simple item record

Page view(s)

20
checked on Oct 26, 2024

Download(s)

3
checked on Oct 26, 2024

Google ScholarTM

Check

Altmetric


Share



Export metadata



Items in accedaCRIS are protected by copyright, with all rights reserved, unless otherwise indicated.