Title: Analysing Histology Hyperspectral Images: Does Tissue Thickness Matter?
Authors: Santana Nuñez,Javier 
Quintana Quintana, Laura 
Fabelo, Himar 
Ortega, Samuel 
Sauras-Colón, Esther
Gallardo-Borràs, Noèlia
Mata-Cano, Daniel
López-Pablo, Carlos
Callicó, Gustavo M. 
UNESCO Clasification: 3314 Tecnología médica
Keywords: Breast Cancer
Histopathological Sample Thickness
Hyperspectral Imaging
Light Tissue Interactions
Issue Date: 2024
Journal: Proceedings Of Spie - The International Society For Optical Engineering
Conference: Biomedical Spectroscopy, Microscopy, and Imaging III 2024
Abstract: Cancer is one of the leading causes of death, thereby, contributing to their quick diagnosis or treatment is of greatest importance. Nowadays, tumours are mainly diagnosed and graded histologically using biopsies. Since the images need to be sharp to distinguish biological structures, samples are thinly sliced (3-5 μm) to avoid scattering and contrast is obtained using highly absorbance dyes (e.g., Haematoxylin and Eosin (H&E)). RGB (Red-Green-Blue) cameras have been widely employed to acquire those images, while new approaches, such as Hyperspectral (HS) Imaging (HSI), have been arising to obtain a greater amount of spectral information from the samples. However, in order to have diffuse light for the HS cameras to capture it, the thickness of the sample should be bigger than the ones employed in conventional microscopy. This work aims to characterize the influence of tissue thickness of histology breast samples sectioned at 2 and 3 μm on their spectral signatures. Based on the H&E transmittance spectra peaks, HS images were segmented into three structures: stroma (eosin-stained), nuclei (haematoxylin-stained), and background (non-stained). Results show that, spatially, in 3 μm samples there are more cells imaged than in 2 μm samples. Moreover, spectrally, 3 μm samples proportionate higher spectral contrast than 2 μm samples due the greater interaction of light with tissue, denoting them as more suitable for microscopic HSI.
URI: http://hdl.handle.net/10553/134387
ISBN: 9781510673281
ISSN: 0277-786X
DOI: 10.1117/12.3017010
Source: Proceedings of SPIE - The International Society for Optical Engineering[ISSN 0277-786X],v. 13006, (Enero 2024)
Appears in Collections:Actas de congresos
Show full item record

Google ScholarTM

Check

Altmetric


Share



Export metadata



Items in accedaCRIS are protected by copyright, with all rights reserved, unless otherwise indicated.