Identificador persistente para citar o vincular este elemento:
http://hdl.handle.net/10553/132737
Campo DC | Valor | idioma |
---|---|---|
dc.contributor.author | Santa-María, Ana L. | en_US |
dc.contributor.author | Agharbi, Marzouk | en_US |
dc.contributor.author | Thams, Carlos B. | en_US |
dc.contributor.author | Martel Fuentes, Oscar | en_US |
dc.date.accessioned | 2024-08-26T10:48:42Z | - |
dc.date.available | 2024-08-26T10:48:42Z | - |
dc.date.issued | 2023 | en_US |
dc.identifier.isbn | 978-3-031-38562-9 | en_US |
dc.identifier.uri | http://hdl.handle.net/10553/132737 | - |
dc.description.abstract | The surgery of the biceps brachii anchors the tendon to the bone, usually using sutures and/or screws. The usual technique is to drill a tunnel in the radius and secure the tendon in it using a small metal piece (button). However, it is also possible to add an interference screw in the bone tunnel to increase the fixation capacity. The objective of this work has been to evaluate the improvement of the repair of the biceps brachii tendon with the use of an interference screw. To this end, reconstructions of the distal tendon were carried out using bones and tendons of animal origin and tested cyclically. The results indicate that adding the screw reduces the displacement and increases the loading capacity significantly. Therefore, the addition of the interference screw is recommended, especially in young and active patients. | en_US |
dc.language | eng | en_US |
dc.publisher | Springer | en_US |
dc.source | Proceedings of the XV Ibero-American Congress of Mechanical Engineering / Vizán Idoipe, A., García Prada, J.C. (eds.), p. 125-131 | en_US |
dc.subject | 240604 Biomecánica | en_US |
dc.subject.other | Biceps brachii tendon | en_US |
dc.subject.other | Interference screw | en_US |
dc.subject.other | Biomechanical tests | en_US |
dc.title | Biomechanical Study of the Addition of the Interferential Screw in the Repair of the Distal Biceps Brachii Tendon | en_US |
dc.type | info:eurepo/ semantics/conferenceObject | en_US |
dc.type | Conference proceedings | en_US |
dc.relation.conference | XV Ibero-American Congress of Mechanical Engineering (IACME 2022) | en_US |
dc.identifier.doi | 10.1007/978-3-031-38563-6_19 | en_US |
dc.description.lastpage | 131 | en_US |
dc.description.firstpage | 125 | en_US |
dc.investigacion | Ingeniería y Arquitectura | en_US |
dc.type2 | Actas de congresos | en_US |
dc.description.numberofpages | 7 | en_US |
dc.utils.revision | Sí | en_US |
dc.date.coverdate | 08/2023 | en_US |
dc.identifier.ulpgc | Sí | en_US |
dc.contributor.buulpgc | BU-ING | en_US |
item.grantfulltext | open | - |
item.fulltext | Con texto completo | - |
crisitem.event.eventsstartdate | 22-11-2022 | - |
crisitem.event.eventsenddate | 24-11-2022 | - |
crisitem.author.dept | GIR Biomaterials and Biomechanics Research Group | - |
crisitem.author.dept | Departamento de Ingeniería Mecánica | - |
crisitem.author.orcid | 0000-0003-3806-5523 | - |
crisitem.author.parentorg | Departamento de Ingeniería Mecánica | - |
crisitem.author.fullName | Martel Fuentes, Oscar | - |
Colección: | Actas de congresos |
Visitas
28
actualizado el 26-oct-2024
Descargas
35
actualizado el 26-oct-2024
Google ScholarTM
Verifica
Altmetric
Comparte
Exporta metadatos
Los elementos en ULPGC accedaCRIS están protegidos por derechos de autor con todos los derechos reservados, a menos que se indique lo contrario.