Identificador persistente para citar o vincular este elemento:
http://hdl.handle.net/10553/130143
Campo DC | Valor | idioma |
---|---|---|
dc.contributor.author | Díaz González, Candelaria Merced | - |
dc.contributor.author | Pérez Bello, Cristina | - |
dc.contributor.author | De La Rosa Hormiga, Milagros | - |
dc.contributor.author | González Henríquez, Juan José | - |
dc.contributor.author | Reyes Noha, María de las Mercedes | - |
dc.date.accessioned | 2024-05-03T17:05:52Z | - |
dc.date.available | 2024-05-03T17:05:52Z | - |
dc.date.issued | 2024 | - |
dc.identifier.issn | 2227-9032 | - |
dc.identifier.other | WoS | - |
dc.identifier.uri | http://hdl.handle.net/10553/130143 | - |
dc.description.abstract | Pulse oximetry is a non-invasive, cost-effective, and generally reliable instrument measuring pulse rate and peripheral oxygen saturation (SpO2). However, these measurements can be affected by the patient’s internal or external factors, including the type of pulse oximeter device (POD). (1) This study’s objective was to identify potential environmental factors that may impact the measurements taken by three PODs. (2) Methods: A descriptive–analytical cross-sectional study was designed. The patients’ SpO2 levels were measured using a standard monitor and two PODs owned by the professionals. The measurements were taken on the patients’ fingers. Concurrently, we evaluated the surrounding environmental conditions, encompassing temperature, humidity, illuminance, and noise. (3) Results: This study involved 288 adult participants in the sample. For each 20-decibel increment in noise, there was a reduction in SpO2 by an average of 1%, whereas for every additional degree of ambient temperature, SpO2 decreased by an average of 2% (4) Conclusions: Significant correlations between SpO2 and age, as well as with noise and ambient temperature, were observed. No significant differences between oxygen saturation and lighting or humidity were observed. This study was prospectively registered with the Clinical Research Ethics Committee of Gran Canaria at the Dr. Negrín University Hospital, with protocol code 2019-247-1, and approved on 24 May 2019. | - |
dc.language | eng | - |
dc.relation.ispartof | Healthcare | - |
dc.source | Healthcare [2227-9032], v. 12(9):940 (Abril 2024) | - |
dc.subject | 32 Ciencias médicas | - |
dc.subject | 3201 Ciencias clínicas | - |
dc.subject.other | Peripheral oximetry | - |
dc.subject.other | Pulse oximeters | - |
dc.subject.other | Environmental factors | - |
dc.subject.other | Temperature | - |
dc.subject.other | Humidity | - |
dc.subject.other | Illuminance | - |
dc.subject.other | Noise | - |
dc.subject.other | Skin phototype | - |
dc.title | Hospital Environmental Factors That Influence Peripheral Oxygen Saturation Measurements: A Cross-Sectional Study | - |
dc.type | info:eu-repo/semantics/article | - |
dc.type | Article | - |
dc.identifier.doi | 10.3390/healthcare12090940 | - |
dc.identifier.isi | 001219837900001 | - |
dc.contributor.orcid | #NODATA# | - |
dc.contributor.orcid | #NODATA# | - |
dc.contributor.orcid | #NODATA# | - |
dc.contributor.orcid | #NODATA# | - |
dc.contributor.orcid | #NODATA# | - |
dc.identifier.eissn | 2227-9032 | - |
dc.identifier.issue | 9 | - |
dc.relation.volume | 12 | - |
dc.investigacion | Ciencias de la Salud | - |
dc.type2 | Artículo | - |
dc.contributor.daisngid | No ID | - |
dc.contributor.daisngid | No ID | - |
dc.contributor.daisngid | No ID | - |
dc.contributor.daisngid | No ID | - |
dc.contributor.daisngid | No ID | - |
dc.description.notas | Proyecto de referencia: ENF19/07 | - |
dc.identifier.external | 158933464 | - |
dc.description.numberofpages | 12 | - |
dc.utils.revision | Sí | - |
dc.contributor.wosstandard | WOS:Díaz-González, CD | - |
dc.contributor.wosstandard | WOS:Pérez-Bello, C | - |
dc.contributor.wosstandard | WOS:De la Rosa-hormiga, M | - |
dc.contributor.wosstandard | WOS:González-Henríquez, JJ | - |
dc.contributor.wosstandard | WOS:Reyes-Noha, MD | - |
dc.date.coverdate | Abril 2024 | - |
dc.identifier.ulpgc | Sí | - |
dc.contributor.buulpgc | BU-MED | - |
dc.description.sjr | 0,606 | - |
dc.description.jcr | 2,4 | - |
dc.description.sjrq | Q2 | - |
dc.description.jcrq | Q2 | - |
dc.description.esci | ESCI | - |
dc.description.miaricds | 8,4 | - |
item.fulltext | Con texto completo | - |
item.grantfulltext | open | - |
crisitem.author.dept | GIR IUIBS: Nutrición | - |
crisitem.author.dept | IU de Investigaciones Biomédicas y Sanitarias | - |
crisitem.author.dept | Departamento de Enfermería | - |
crisitem.author.dept | Departamento de Enfermería | - |
crisitem.author.dept | GIR IUIBS: Nutrición | - |
crisitem.author.dept | IU de Investigaciones Biomédicas y Sanitarias | - |
crisitem.author.dept | Departamento de Enfermería | - |
crisitem.author.dept | GIR IUIBS: Rendimiento humano, ejercicio físico y salud | - |
crisitem.author.dept | IU de Investigaciones Biomédicas y Sanitarias | - |
crisitem.author.dept | Departamento de Matemáticas | - |
crisitem.author.orcid | 0000-0003-1797-4752 | - |
crisitem.author.orcid | 0000-0002-6768-0982 | - |
crisitem.author.orcid | 0000-0002-0622-5580 | - |
crisitem.author.parentorg | IU de Investigaciones Biomédicas y Sanitarias | - |
crisitem.author.parentorg | IU de Investigaciones Biomédicas y Sanitarias | - |
crisitem.author.parentorg | IU de Investigaciones Biomédicas y Sanitarias | - |
crisitem.author.fullName | Díaz González, Candelaria Merced | - |
crisitem.author.fullName | Pérez Bello, Cristina | - |
crisitem.author.fullName | De La Rosa Hormiga, Milagros | - |
crisitem.author.fullName | González Henríquez, Juan José | - |
Colección: | Artículos |
Los elementos en ULPGC accedaCRIS están protegidos por derechos de autor con todos los derechos reservados, a menos que se indique lo contrario.