Identificador persistente para citar o vincular este elemento: http://hdl.handle.net/10553/130143
Campo DC Valoridioma
dc.contributor.authorDíaz González, Candelaria Merced-
dc.contributor.authorPérez Bello, Cristina-
dc.contributor.authorDe La Rosa Hormiga, Milagros-
dc.contributor.authorGonzález Henríquez, Juan José-
dc.contributor.authorReyes Noha, María de las Mercedes-
dc.date.accessioned2024-05-03T17:05:52Z-
dc.date.available2024-05-03T17:05:52Z-
dc.date.issued2024-
dc.identifier.issn2227-9032-
dc.identifier.otherWoS-
dc.identifier.urihttp://hdl.handle.net/10553/130143-
dc.description.abstractPulse oximetry is a non-invasive, cost-effective, and generally reliable instrument measuring pulse rate and peripheral oxygen saturation (SpO2). However, these measurements can be affected by the patient’s internal or external factors, including the type of pulse oximeter device (POD). (1) This study’s objective was to identify potential environmental factors that may impact the measurements taken by three PODs. (2) Methods: A descriptive–analytical cross-sectional study was designed. The patients’ SpO2 levels were measured using a standard monitor and two PODs owned by the professionals. The measurements were taken on the patients’ fingers. Concurrently, we evaluated the surrounding environmental conditions, encompassing temperature, humidity, illuminance, and noise. (3) Results: This study involved 288 adult participants in the sample. For each 20-decibel increment in noise, there was a reduction in SpO2 by an average of 1%, whereas for every additional degree of ambient temperature, SpO2 decreased by an average of 2% (4) Conclusions: Significant correlations between SpO2 and age, as well as with noise and ambient temperature, were observed. No significant differences between oxygen saturation and lighting or humidity were observed. This study was prospectively registered with the Clinical Research Ethics Committee of Gran Canaria at the Dr. Negrín University Hospital, with protocol code 2019-247-1, and approved on 24 May 2019.-
dc.languageeng-
dc.relation.ispartofHealthcare-
dc.sourceHealthcare [2227-9032], v. 12(9):940 (Abril 2024)-
dc.subject32 Ciencias médicas-
dc.subject3201 Ciencias clínicas-
dc.subject.otherPeripheral oximetry-
dc.subject.otherPulse oximeters-
dc.subject.otherEnvironmental factors-
dc.subject.otherTemperature-
dc.subject.otherHumidity-
dc.subject.otherIlluminance-
dc.subject.otherNoise-
dc.subject.otherSkin phototype-
dc.titleHospital Environmental Factors That Influence Peripheral Oxygen Saturation Measurements: A Cross-Sectional Study-
dc.typeinfo:eu-repo/semantics/article-
dc.typeArticle-
dc.identifier.doi10.3390/healthcare12090940-
dc.identifier.isi001219837900001-
dc.contributor.orcid#NODATA#-
dc.contributor.orcid#NODATA#-
dc.contributor.orcid#NODATA#-
dc.contributor.orcid#NODATA#-
dc.contributor.orcid#NODATA#-
dc.identifier.eissn2227-9032-
dc.identifier.issue9-
dc.relation.volume12-
dc.investigacionCiencias de la Salud-
dc.type2Artículo-
dc.contributor.daisngidNo ID-
dc.contributor.daisngidNo ID-
dc.contributor.daisngidNo ID-
dc.contributor.daisngidNo ID-
dc.contributor.daisngidNo ID-
dc.description.notasProyecto de referencia: ENF19/07-
dc.identifier.external158933464-
dc.description.numberofpages12-
dc.utils.revision-
dc.contributor.wosstandardWOS:Díaz-González, CD-
dc.contributor.wosstandardWOS:Pérez-Bello, C-
dc.contributor.wosstandardWOS:De la Rosa-hormiga, M-
dc.contributor.wosstandardWOS:González-Henríquez, JJ-
dc.contributor.wosstandardWOS:Reyes-Noha, MD-
dc.date.coverdateAbril 2024-
dc.identifier.ulpgc-
dc.contributor.buulpgcBU-MED-
dc.description.sjr0,55-
dc.description.jcr2,8-
dc.description.sjrqQ2-
dc.description.jcrqQ2-
dc.description.esciESCI-
dc.description.miaricds8,4-
item.grantfulltextopen-
item.fulltextCon texto completo-
crisitem.author.deptGIR IUIBS: Nutrición-
crisitem.author.deptIU de Investigaciones Biomédicas y Sanitarias-
crisitem.author.deptDepartamento de Enfermería-
crisitem.author.deptDepartamento de Enfermería-
crisitem.author.deptGIR IUIBS: Nutrición-
crisitem.author.deptIU de Investigaciones Biomédicas y Sanitarias-
crisitem.author.deptDepartamento de Enfermería-
crisitem.author.deptGIR IUIBS: Rendimiento humano, ejercicio físico y salud-
crisitem.author.deptIU de Investigaciones Biomédicas y Sanitarias-
crisitem.author.deptDepartamento de Matemáticas-
crisitem.author.orcid0000-0003-1797-4752-
crisitem.author.orcid0000-0002-6768-0982-
crisitem.author.orcid0000-0002-0622-5580-
crisitem.author.parentorgIU de Investigaciones Biomédicas y Sanitarias-
crisitem.author.parentorgIU de Investigaciones Biomédicas y Sanitarias-
crisitem.author.parentorgIU de Investigaciones Biomédicas y Sanitarias-
crisitem.author.fullNameDíaz González, Candelaria Merced-
crisitem.author.fullNamePérez Bello, Cristina-
crisitem.author.fullNameDe La Rosa Hormiga, Milagros-
crisitem.author.fullNameGonzález Henríquez, Juan José-
Colección:Artículos
Adobe PDF (322,57 kB)
Vista resumida

Google ScholarTM

Verifica

Altmetric


Comparte



Exporta metadatos



Los elementos en ULPGC accedaCRIS están protegidos por derechos de autor con todos los derechos reservados, a menos que se indique lo contrario.