Please use this identifier to cite or link to this item: http://hdl.handle.net/10553/128462
Title: Refactoring and performance analysis of the main CNN architectures: using false negative rate minimization to solve the clinical images melanoma detection problem
Authors: Di Biasi, Luigi
De Marco, Fabiola
Citarella, Alessia Auriemma
Castrillón Santana, Modesto 
Barra, Paola
Tortora, Genoveffa
UNESCO Clasification: 120304 Inteligencia artificial
220990 Tratamiento digital. Imágenes
33 Ciencias tecnológicas
Keywords: Melanoma
Skin cancer
Deep leaning
IoMT
Issue Date: 2023
Journal: BMC Bioinformatics 
Abstract: Background: Melanoma is one of the deadliest tumors in the world. Early detection is critical for first-line therapy in this tumor pathology and it remains challenging due to the need for histological analysis to ensure correctness in diagnosis. Therefore, multiple computer-aided diagnosis (CAD) systems working on melanoma images were proposed to mitigate the need of a biopsy. However, although the high global accuracy is declared in literature results, the CAD systems for the health fields must focus on the lowest false negative rate (FNR) possible to qualify as a diagnosis support system. The final goal must be to avoid classification type 2 errors to prevent life-threatening situations. Another goal could be to create an easy-to-use system for both physicians and patients. Results: To achieve the minimization of type 2 error, we performed a wide exploratory analysis of the principal convolutional neural network (CNN) architectures published for the multiple image classification problem; we adapted these networks to the melanoma clinical image binary classification problem (MCIBCP). We collected and analyzed performance data to identify the best CNN architecture, in terms of FNR, usable for solving the MCIBCP problem. Then, to provide a starting point for an easy-to-use CAD system, we used a clinical image dataset (MED-NODE) because clinical images are easier to access: they can be taken by a smartphone or other hand-size devices. Despite the lower resolution than dermoscopic images, the results in the literature would suggest that it would be possible to achieve high classification performance by using clinical images. In this work, we used MED-NODE, which consists of 170 clinical images (70 images of melanoma and 100 images of naevi). We optimized the following CNNs for the MCIBCP problem: Alexnet, DenseNet, GoogleNet Inception V3, GoogleNet, MobileNet, ShuffleNet, SqueezeNet, and VGG16. Conclusions: The results suggest that a CNN built on the VGG or AlexNet structure can ensure the lowest FNR (0.07) and (0.13), respectively. In both cases, discrete global performance is ensured: 73% (accuracy), 82% (sensitivity) and 59% (specificity) for VGG; 89% (accuracy), 87% (sensitivity) and 90% (specificity) for AlexNet.
URI: http://hdl.handle.net/10553/128462
ISSN: 1471-2105
DOI: 10.1186/s12859-023-05516-5
Source: BMC Bioinformatics 24, 386 (2023)
Appears in Collections:Artículos
Adobe PDF (2,67 MB)
Show full item record

SCOPUSTM   
Citations

14
checked on Nov 17, 2024

WEB OF SCIENCETM
Citations

9
checked on Nov 17, 2024

Page view(s)

52
checked on Oct 5, 2024

Download(s)

41
checked on Oct 5, 2024

Google ScholarTM

Check

Altmetric


Share



Export metadata



Items in accedaCRIS are protected by copyright, with all rights reserved, unless otherwise indicated.