Please use this identifier to cite or link to this item: http://hdl.handle.net/10553/127937
Title: Stimulation Crosstalk Between Cochlear And Vestibular Spaces During Cochlear Electrical Stimulation
Authors: Ramos De Miguel, Ángel 
Rodriguez Montesdeoca, Isaura
Falcón González, Juan Carlos
Borkoski Barreiro, Silvia
Zarowski, Andrzej
Sluydts, Morgana
Falcón Benitez, Nadia
Ramos Macías, Ángel Manuel 
UNESCO Clasification: 32 Ciencias médicas
Keywords: Basic Science
Cochlear Implants
Vestibular Implant
Issue Date: 2023
Journal: Laryngoscope
Abstract: Objectives: Possible beneficial “crosstalk” during cochlear implant stimulation on otolith end organs has been hypothesized. The aim of this case–control study is to analyze the effect of electrical cochlear stimulation on the vestibule (otolith end-organ), when using a cochleo-vestibular implant, comparing vestibular stimulation (VI) and cochlear stimulation (CI). Methods: Four patients with bilateral vestibulopathy were included. A double electrode array research implant was implanted in all cases. Dynamic Gait Index (DGI), VOR gain measured by using vestibular head impulse test (vHIT), acoustic cervical myogenic responses (cVEMP) recordings, and electrical cVEMP were used in all cases. Trans-impedance Matrix (TIM) analysis was used to evaluate the current flow from the cochlea to the vestibule. Results: While patients did not have any clinical vestibular improvement with the CI stimulation alone, gait metrics of the patients revealed improvement when the vestibular electrode was stimulated. The average improvement in the DGI was 38% when the vestibular implant was activated, returning to the normal range in all cases. Our findings suggest that any current flow from the cochlear space to the otolith organs was insufficient for effective cross-stimulation. The functional results correlated with the data obtained in TIM analysis, confirming that there is no current flow from the cochlea to the vestibule. Conclusion: The only way to produce effective electrical otolith end-organ stimulation, demonstrated with this research implant, is by direct electrical stimulation of the otolith end organs. No effective cross-stimulation was found from cochlear electrode stimulation. Level of Evidence: 4
URI: http://hdl.handle.net/10553/127937
ISSN: 0023-852X
DOI: 10.1002/lary.31174
Source: Laryngoscope [ISSN 0023-852X], (Enero 2023).
Appears in Collections:Artículos
Adobe PDF (835,71 kB)
Show full item record

Google ScholarTM

Check

Altmetric


Share



Export metadata



Items in accedaCRIS are protected by copyright, with all rights reserved, unless otherwise indicated.