Identificador persistente para citar o vincular este elemento: http://hdl.handle.net/10553/123003
Título: Extraction methodologies to micropollutans adsorb on microplastics
Autores/as: Pacheco Juárez, Javier 
Guedes Alonso, Raico Iván 
Montesdeoca Esponda, Sarah 
Santana Viera, Sergio 
Santana Rodríguez, José Juan 
Torres Padrón, María Esther 
Sosa Ferrera, María Zoraida 
Clasificación UNESCO: 251002 Oceanografía química
330811 Control de la contaminación del agua
331210 Plásticos
230111 Análisis microquímico
Palabras clave: UV filters
Hormones
Drugs
Ultrasound-assisted extraction
Fecha de publicación: 2023
Editor/a: Servicio de Publicaciones y Difusión Científica de la Universidad de Las Palmas de Gran Canaria (ULPGC) 
Proyectos: Evaluación del impacto de microplásticos y contaminantes emergentes en las costas de la Macaronesia 
Conferencia: II International Workshop on Marine Litter (BAMAR 2022) 
Resumen: Microplastics are ubiquitous in the marine environment and can cause negative effects on organisms. In addition, they can also adsorb a variety of pollutants and can act as pollutant carriers. In the IMPLAMAC project, different analytical methodologies are developed to determine different types of organic pollutant, such as UV filters and stabilisers (Montesdeoca- Esponda et al., 2021), hormones (Guedes-Alonso et al., 2021) and drugs (Santana-Viera et al., 2020), whose presence in the environment is booming with the increase in population. Extractions were carried out by ultrasound-assisted extraction (UAE) and the determination by ultrahigh-performance liquid chromatography with tandem mass spectrometry detection (UHPLC-MS/MS). 300 mg of pellets and microplastic fragments were used to obtain the best extraction condition for the different targeted micropollutants. The method for UVFs and UVSs displayed values lower than 22% and 28% for intraday precision and interday precision, and limits of detection (LODs) were obtained from 0.01 to 0.69 ng·g-1 and limits of quantification (LOQs) were from 0.02 to 2.29 ng·g-1. Regarding the analytical method for hormones, it showed intraday and interday precisions below 20% for most compounds, with LODs between 0.07 and 27.5 ng·g-1 and LOQs ranging from 0.23 to 91.7 ng·g-1. Respecting drugs method, relative standard deviations lower than 15% were obtained for intraday and interday precisions in most cases. LODs ranged from 0.25 to 15.8 ng·g-1 and LOQs were between 0.82 and 52.7 ng·g-1
URI: http://hdl.handle.net/10553/123003
ISBN: 978-84-9042-480-3
Fuente: Libro de Abstracs del II International Workshop on Marine Litter (BAMAR 2022) / María Esther Torres Padrón (ed.), p. 121-122
Colección:Póster de congreso
Adobe PDF (500,61 kB)
Vista completa

Visitas

99
actualizado el 09-nov-2024

Descargas

20
actualizado el 09-nov-2024

Google ScholarTM

Verifica

Altmetric


Comparte



Exporta metadatos



Los elementos en ULPGC accedaCRIS están protegidos por derechos de autor con todos los derechos reservados, a menos que se indique lo contrario.