Identificador persistente para citar o vincular este elemento: http://hdl.handle.net/10553/119038
Campo DC Valoridioma
dc.contributor.authorAlvero-Cruz, José Ramónen_US
dc.contributor.authorGarcia-Romero, Jerónimo C.en_US
dc.contributor.authorCarrillo de Albornoz-Gil, Margaritaen_US
dc.contributor.authorJiménez, Manuelen_US
dc.contributor.authorCorreas-Gómez, Lorenaen_US
dc.contributor.authorPeñaloza Polo, Pieroen_US
dc.contributor.authorLópez-Fernández, Ivánen_US
dc.contributor.authorCarnero, Elvis A.en_US
dc.date.accessioned2022-10-24T14:48:51Z-
dc.date.available2022-10-24T14:48:51Z-
dc.date.issued2018en_US
dc.identifier.issn0954-3007en_US
dc.identifier.urihttp://hdl.handle.net/10553/119038-
dc.description.abstractThe main goal of this study was to analyze the longitudinal agreement between changes in trunk and abdominal adiposity variables assessed by DXA and portable bioimpedance device (ViScan). A total of 44 women, enrolled in a 4-month exercise intervention, were included in this analysis. Trunk/abdominal compartments were assessed by ViScan and DXA. Adjusted correlations for age and FM at first assessment (pre) were utilized to perform concurrent validation among methods and completed with an agreement analysis. We observed significant differences between the changes detected by DXA and ViScan for %TFM (difference = -1.41%; p < 0.05), and proportional bias (Kendall's Tau = 0.53; p < 0.0001). Changes in abdominal adiposity were similar (difference = -0.1037 z-score units, p = 0.53), although there was proportional bias (Kendall's Tau = -0.24, p < 0.022). ViScan has a limited capability to evaluated changes in trunk and abdominal adiposity, at least for clinical purposes in adult women.en_US
dc.languageengen_US
dc.relation.ispartofEuropean Journal of Clinical Nutritionen_US
dc.sourceEuropean Journal of Clinical Nutrition [eISSN:1476-5640], v. 72, pp. 1055-1057 (Marzo 2018)en_US
dc.subject32 Ciencias médicasen_US
dc.subject3206 Ciencias de la nutriciónen_US
dc.subject.otherBiomarkersen_US
dc.subject.otherRisk factorsen_US
dc.subject.otherViScanen_US
dc.subject.otherDXAen_US
dc.titleLongitudinal validity of abdominal adiposity assessment by regional bioelectrical impedanceen_US
dc.typeinfo:eu-repo/semantics/articleen_US
dc.typeArticleen_US
dc.identifier.doi10.1038/s41430-018-0129-7en_US
dc.identifier.pmid29559722-
dc.identifier.scopus2-s2.0-85044223718-
dc.identifier.isiWOS:000438062800018-
dc.contributor.orcid#NODATA#-
dc.contributor.orcid#NODATA#-
dc.contributor.orcid#NODATA#-
dc.contributor.orcid#NODATA#-
dc.contributor.orcid0000-0002-1838-8993-
dc.contributor.orcid#NODATA#-
dc.contributor.orcid#NODATA#-
dc.contributor.orcid0000-0003-0442-4217-
dc.description.lastpage1057en_US
dc.identifier.issue7-
dc.description.firstpage1055en_US
dc.relation.volume72en_US
dc.investigacionCiencias de la Saluden_US
dc.type2Artículoen_US
dc.description.numberofpages3en_US
dc.utils.revisionen_US
dc.date.coverdateMarzo 2018en_US
dc.identifier.ulpgcen_US
dc.contributor.buulpgcBU-MEDen_US
dc.description.sjr1,307
dc.description.jcr3,114
dc.description.sjrqQ1
dc.description.jcrqQ2
dc.description.scieSCIE
item.grantfulltextnone-
item.fulltextSin texto completo-
crisitem.author.orcid0000-0001-5354-7673-
crisitem.author.fullNamePeñaloza Polo, Piero-
Colección:Artículos
Vista resumida

Visitas

33
actualizado el 29-jun-2024

Google ScholarTM

Verifica

Altmetric


Comparte



Exporta metadatos



Los elementos en ULPGC accedaCRIS están protegidos por derechos de autor con todos los derechos reservados, a menos que se indique lo contrario.