Please use this identifier to cite or link to this item: http://hdl.handle.net/10553/116692
DC FieldValueLanguage
dc.contributor.authorHernández Sosa, José Danielen_US
dc.contributor.authorCabrera Gámez, Jorgeen_US
dc.contributor.authorNaranjo, Aen_US
dc.contributor.authorDomínguez Brito, Antonio Carlosen_US
dc.contributor.authorIsern González, Joséen_US
dc.date.accessioned2022-07-11T11:02:50Z-
dc.date.available2022-07-11T11:02:50Z-
dc.date.issued2007en_US
dc.identifier.urihttp://hdl.handle.net/10553/116692-
dc.description.abstractMany methods have been developed in the last few years to self-calibrate cameras, but few works have addressed a comparison of such methods to provide the user with hints on the suitability of certain algorithms under particular circumstances. The few of these works that analyze self-calibration methods have concentrated on the study of the influence of some factors [1] [2] or the identification of critical movements [3], but there are not any studies analyzing the accuracy and stability of these methods. This work presents a comparative analysis of four methods of self-calibration for cameras which only rotate (without translation movement): McLauchlan’s method [4] that assumes that the camera setup is fixed along the sequence; and Agapito’s methods (linear [5] and iterative [6] algorithms) and Seo’s method [7] that allow the variation of optic center and scale factors. The experiments discussed in this paper have focused on characterizing the accuracy in the point reconstruction (global error) and the stability and accuracy of the estimation of the internal camera parameters. These experiments were performed with both a real camera and a simulator. When only the extrinsic parameters vary in a sequence used to calibrate a camera the estimated values for the intrinsic parameters in each image of this sequence should be the same. The variability in the estimation of the intrinsic parameters along the sequence was measured to know the stability of the methods. The experiments carried out showed that, despite the camera configuration was kept constant along the sequence, there were variations across all methods by intrinsic parameters. For example, this variability represented 4% of the ground truth value in the optic center when simulated images was used and 3% when real images were analyzed. Additionally, the estimated values of intrinsic parameters obtained by the methods had differences between them, especially in the scale factors (4% using simulated data and 2.5% using real data). In the simulator, the accuracy of each parameter could be analyzed. It was observed that the versions of Agapito’s method obtained values closer to ground truth value of the optic center than Seo’s method. McLauchlan’s method obtained a high accuracy in scale factor due to the fact that it estimates only one value for all the sequence and the remaining methods studied presented a little inaccuracy (4.5%). However, the global error of McLauchlan’s method had the highest value and Agapito’s method obtained a very low level for this error. In real conditions, the results of these self-calibration methods were compared with a manual calibration method (Batista’s method [8])). In general, while the manual method offered more stable results across the sequence, the performance of the self-calibration methods was comparable to that achieved by Batista’s method. The self-calibration method that obtained closer values to this method was McLauchlan’s method, which turned out to be the most precise method in the simulator. Finally, the effect of the length of the sequence in the accuracy of each parameter was studied. The results showed that 30 images were enough to obtain minimum levels of errors in all methods, but McLauchlan’s method, although it had less error, needed more images to minimize the error. On the other hand, when the run time was compared, it could be observed that Seo’s method had a high computational cost, especially in long sequences. To summarize, the experiments carried out have shown that the optic center is the most unstable parameter for all methods and that the larger discrepancies among the estimated values appear with the scale factors. Also, the results returned by any of these methods are comparable in terms of stability and accuracy with those provided by a well-known manual calibration method.en_US
dc.languageengen_US
dc.subject1203 Ciencia de los ordenadoresen_US
dc.subject.otherSelf-calibrationen_US
dc.subject.otherStatic camerasen_US
dc.titleComparing self-calibration methods for static camerasen_US
dc.typeinfo:eu-repo/semantics/conferenceobjecten_US
dc.typeConferenceObjecten_US
dc.relation.conferenceInternational Conference on Computer Aided Systems Theory(EUROCAST)en_US
dc.investigacionIngeniería y Arquitecturaen_US
dc.type2Actas de congresosen_US
dc.utils.revisionen_US
dc.date.coverdate2007en_US
dc.identifier.ulpgcen_US
dc.contributor.buulpgcBU-INGen_US
item.grantfulltextopen-
item.fulltextCon texto completo-
crisitem.author.deptGIR SIANI: Inteligencia Artificial, Robótica y Oceanografía Computacional-
crisitem.author.deptIU Sistemas Inteligentes y Aplicaciones Numéricas-
crisitem.author.deptDepartamento de Informática y Sistemas-
crisitem.author.deptGIR SIANI: Inteligencia Artificial, Robótica y Oceanografía Computacional-
crisitem.author.deptIU Sistemas Inteligentes y Aplicaciones Numéricas-
crisitem.author.deptDepartamento de Informática y Sistemas-
crisitem.author.deptGIR SIANI: Inteligencia Artificial, Robótica y Oceanografía Computacional-
crisitem.author.deptIU Sistemas Inteligentes y Aplicaciones Numéricas-
crisitem.author.deptDepartamento de Informática y Sistemas-
crisitem.author.deptGIR SIANI: Inteligencia Artificial, Robótica y Oceanografía Computacional-
crisitem.author.deptIU Sistemas Inteligentes y Aplicaciones Numéricas-
crisitem.author.deptDepartamento de Filología Moderna, Traducción e Interpretación-
crisitem.author.orcid0000-0003-3022-7698-
crisitem.author.orcid0000-0002-0260-4524-
crisitem.author.orcid0000-0002-3252-5683-
crisitem.author.orcid0000-0001-5830-7732-
crisitem.author.parentorgIU Sistemas Inteligentes y Aplicaciones Numéricas-
crisitem.author.parentorgIU Sistemas Inteligentes y Aplicaciones Numéricas-
crisitem.author.parentorgIU Sistemas Inteligentes y Aplicaciones Numéricas-
crisitem.author.parentorgIU Sistemas Inteligentes y Aplicaciones Numéricas-
crisitem.author.fullNameHernández Sosa, José Daniel-
crisitem.author.fullNameCabrera Gámez, Jorge-
crisitem.author.fullNameDomínguez Brito, Antonio Carlos-
crisitem.author.fullNameIsern González, José-
Appears in Collections:Actas de congresos
Adobe PDF (106,11 kB)
Show simple item record

Page view(s)

87
checked on Nov 23, 2024

Download(s)

48
checked on Nov 23, 2024

Google ScholarTM

Check


Share



Export metadata



Items in accedaCRIS are protected by copyright, with all rights reserved, unless otherwise indicated.