Identificador persistente para citar o vincular este elemento:
http://hdl.handle.net/10553/116173
Campo DC | Valor | idioma |
---|---|---|
dc.contributor.author | Rodríguez Barrera, Eduardo Miguel | en_US |
dc.contributor.author | Montero García, Gustavo | en_US |
dc.contributor.author | Montenegro Armas, Rafael | en_US |
dc.contributor.author | Escobar Sánchez, José M | en_US |
dc.contributor.author | Rodríguez Jiménez, E. | en_US |
dc.date.accessioned | 2022-07-07T11:13:12Z | - |
dc.date.available | 2022-07-07T11:13:12Z | - |
dc.date.issued | 2008 | en_US |
dc.identifier.isbn | 978-84-96736-55-9 | en_US |
dc.identifier.uri | http://hdl.handle.net/10553/116173 | - |
dc.description.abstract | Environmental pollution is one of today’s greatest world concerns. Using renewable energies, like windpower generated electricity, is encorauged by governments all over the world and will demand better strategies of both placing and exploiting wind farms. One of the issues that wind farm companies must face is the accurate prediction of power they will produce in the near future, tipically next 24-48 hours. MM5 is a widedly extended mesoscale atmospheric predictive model of atmospheric circulation. We have focused on its wind prediction capabilities, which allows a maximal resolution of 1 × 1 km. This resolution is not enough for solving problems in local areas, like location of wind farms. In contrast, mass consistent models (MCM) belong to the category of diagnostic models. They can be used to obtain wind fields over complex terrain, represented with adapted meshes and using finite element method, but they can’t predict at all. In this work we propose the use of the MM5 predictions as input wind field to a mass consistent model in order to obtain a more accurate prediction in a local area. This, in turn, would lead to a better prevision of electrical power generation of wind farms in the short term. We also present a comparison between some MM5 raw wind predictions versus MM5-MCM corrected predictions over Gran Canaria Islad. | en_US |
dc.language | eng | en_US |
dc.publisher | CIMNE | en_US |
dc.source | 8th World Congress on Computational Mechanics, (WCCM8) - 5th European Congress on Computational Methods in Applied Sciences and Engineering, (ECCOMAS 2008), a2909 | en_US |
dc.subject | 251091 Recursos renovables | en_US |
dc.subject | 3306 Ingeniería y tecnología eléctricas | en_US |
dc.subject | 332205 Fuentes no convencionales de energía | en_US |
dc.subject | 1206 Análisis numérico | en_US |
dc.subject.other | Wind modelling | en_US |
dc.subject.other | MM5 | en_US |
dc.subject.other | Mass Consistent Model | en_US |
dc.title | A combined approach to local scale wind prediction | en_US |
dc.type | info:eu-repo/semantics/conferenceobject | en_US |
dc.type | ConferenceObject | en_US |
dc.relation.conference | 8th World Congress on Computational Mechanics, (WCCM8) - 5th European Congress on Computational Methods in Applied Sciences and Engineering, (ECCOMAS 2008) | en_US |
dc.description.firstpage | a2909 | en_US |
dc.relation.volume | 8 | en_US |
dc.investigacion | Ingeniería y Arquitectura | en_US |
dc.type2 | Actas de congresos | en_US |
dc.description.numberofpages | 1 | en_US |
dc.utils.revision | Sí | en_US |
dc.date.coverdate | Junio 2008 | en_US |
dc.identifier.ulpgc | Sí | en_US |
dc.contributor.buulpgc | BU-ING | en_US |
item.grantfulltext | restricted | - |
item.fulltext | Con texto completo | - |
crisitem.event.eventsstartdate | 30-06-2008 | - |
crisitem.event.eventsenddate | 04-07-2008 | - |
crisitem.author.dept | GIR SIANI: Modelización y Simulación Computacional | - |
crisitem.author.dept | IU Sistemas Inteligentes y Aplicaciones Numéricas | - |
crisitem.author.dept | Departamento de Informática y Sistemas | - |
crisitem.author.dept | GIR SIANI: Modelización y Simulación Computacional | - |
crisitem.author.dept | IU Sistemas Inteligentes y Aplicaciones Numéricas | - |
crisitem.author.dept | Departamento de Matemáticas | - |
crisitem.author.dept | GIR SIANI: Modelización y Simulación Computacional | - |
crisitem.author.dept | IU Sistemas Inteligentes y Aplicaciones Numéricas | - |
crisitem.author.dept | Departamento de Matemáticas | - |
crisitem.author.dept | GIR SIANI: Modelización y Simulación Computacional | - |
crisitem.author.dept | IU Sistemas Inteligentes y Aplicaciones Numéricas | - |
crisitem.author.dept | Departamento de Señales y Comunicaciones | - |
crisitem.author.orcid | 0000-0002-2701-2971 | - |
crisitem.author.orcid | 0000-0001-5641-442X | - |
crisitem.author.orcid | 0000-0002-4164-457X | - |
crisitem.author.orcid | 0000-0002-8608-7076 | - |
crisitem.author.parentorg | IU Sistemas Inteligentes y Aplicaciones Numéricas | - |
crisitem.author.parentorg | IU Sistemas Inteligentes y Aplicaciones Numéricas | - |
crisitem.author.parentorg | IU Sistemas Inteligentes y Aplicaciones Numéricas | - |
crisitem.author.parentorg | IU Sistemas Inteligentes y Aplicaciones Numéricas | - |
crisitem.author.fullName | Rodríguez Barrera, Eduardo Miguel | - |
crisitem.author.fullName | Montero García, Gustavo | - |
crisitem.author.fullName | Montenegro Armas, Rafael | - |
crisitem.author.fullName | Escobar Sánchez, José M | - |
Colección: | Actas de congresos |
Los elementos en ULPGC accedaCRIS están protegidos por derechos de autor con todos los derechos reservados, a menos que se indique lo contrario.