Please use this identifier to cite or link to this item: http://hdl.handle.net/10553/113410
DC FieldValueLanguage
dc.contributor.authorSocorro Perdomo, Pedro Pabloen_US
dc.contributor.authorFlorido Suárez, Néstor Rubénen_US
dc.contributor.authorMirza Rosca, Julia Claudiaen_US
dc.contributor.authorSaceleanu, Mircea Vicentiuen_US
dc.date.accessioned2022-01-19T09:10:45Z-
dc.date.available2022-01-19T09:10:45Z-
dc.date.issued2022en_US
dc.identifier.issn1996-1944en_US
dc.identifier.otherScopus-
dc.identifier.urihttp://hdl.handle.net/10553/113410-
dc.description.abstractThe increased popularity of Ti and its alloys as important biomaterials is driven by their low modulus, greater biocompatibility, and better corrosion resistance in comparison to traditional biomaterials, such as stainless steel and Co–Cr alloys. Ti alloys are successfully used in severe stress situations, such as Ti–6Al–4V, but this alloy is related to long-term health problems and, in response, different Ti alloys composed of non-toxic and non-allergic elements such as Nb, Zr, Mo, and Ta have been developed for biomedical applications. In this context, binary alloys of titanium and tantalum have been developed and are predicted to be potential products for medical purposes. More than this, today, novel biocompatible alloys such as high entropy alloys with Ti and Ta are considered for biomedical applications and therefore it is necessary to clarify the influence of tantalum on the behavior of the alloy. In this study, various Ti–xTa alloys (with x = 5, 15, 25, and 30) were characterized using different techniques. High-resolution maps of the materials’ surfaces were generated by scanning tunneling microscopy (STM), and atom distribution maps were obtained by energy dispersive X-ray spectroscopy (EDS). A thorough output of chemical composition, and hence the crystallographic structure of the alloys, was identified by X-ray diffraction (XRD). Additionally, the electrochemical behavior of these Ti–Ta alloys was investigated by EIS in simulated body fluid at different potentials. The passive layer resistance increases with the potential due to the formation of the passive layer of TiO2 and Ta2O5 and then decreases due to the dissolution processes through the passive film. Within the Ti–xTa alloys, Ti–25Ta demonstrates excellent passive layer and corrosion resistance properties, so it seems to be a promising product for metallic medical devices.en_US
dc.languageengen_US
dc.relation.ispartofMaterialsen_US
dc.sourceMaterials [ISSN 1996-1944],v. 15 (2), 476, (Enero 2022)en_US
dc.subject330307 Tecnología de la corrosiónen_US
dc.subject331209 Resistencia de materialesen_US
dc.subject.otherCorrosionen_US
dc.subject.otherElectrochemical Impedance Spectroscopyen_US
dc.subject.otherTi–Ta Alloysen_US
dc.titleEIS Characterization of Ti Alloys in Relation to Alloying Additions of Taen_US
dc.typeinfo:eu-repo/semantics/Articleen_US
dc.typeArticleen_US
dc.identifier.doi10.3390/ma15020476en_US
dc.identifier.scopus85122450931-
dc.contributor.orcidNO DATA-
dc.contributor.orcidNO DATA-
dc.contributor.orcidNO DATA-
dc.contributor.orcidNO DATA-
dc.contributor.authorscopusid57196010052-
dc.contributor.authorscopusid35811216900-
dc.contributor.authorscopusid6602582214-
dc.contributor.authorscopusid56453310300-
dc.identifier.eissn1996-1944-
dc.identifier.issue2-
dc.relation.volume15en_US
dc.investigacionIngeniería y Arquitecturaen_US
dc.type2Artículoen_US
dc.description.numberofpages15en_US
dc.utils.revisionen_US
dc.date.coverdateEnero 2022en_US
dc.identifier.ulpgcen_US
dc.contributor.buulpgcBU-INGen_US
dc.description.sjr0,563-
dc.description.jcr3,4-
dc.description.sjrqQ2-
dc.description.jcrqQ2-
dc.description.scieSCIE-
dc.description.miaricds10,6
item.fulltextCon texto completo-
item.grantfulltextopen-
crisitem.author.deptGIR Nanomaterials and Corrosion-
crisitem.author.deptDepartamento de Ingeniería Mecánica-
crisitem.author.deptGIR SIANI: Mecánica de los Medios Continuos y Estructuras-
crisitem.author.deptIU Sistemas Inteligentes y Aplicaciones Numéricas-
crisitem.author.deptDepartamento de Ingeniería Civil-
crisitem.author.deptGIR Nanomaterials and Corrosion-
crisitem.author.deptDepartamento de Ingeniería Mecánica-
crisitem.author.orcid0000-0002-1824-6792-
crisitem.author.orcid0000-0003-0623-3318-
crisitem.author.parentorgDepartamento de Ingeniería Mecánica-
crisitem.author.parentorgIU Sistemas Inteligentes y Aplicaciones Numéricas-
crisitem.author.parentorgDepartamento de Ingeniería Mecánica-
crisitem.author.fullNameSocorro Perdomo, Pedro Pablo-
crisitem.author.fullNameFlorido Suárez, Néstor Rubén-
crisitem.author.fullNameMirza Rosca, Julia Claudia-
Appears in Collections:Artículos
Adobe PDF (6,74 MB)
Show simple item record

SCOPUSTM   
Citations

33
checked on Mar 2, 2025

WEB OF SCIENCETM
Citations

29
checked on Mar 2, 2025

Page view(s)

58
checked on May 11, 2024

Google ScholarTM

Check

Altmetric


Share



Export metadata



Items in accedaCRIS are protected by copyright, with all rights reserved, unless otherwise indicated.