dc.description.abstractThis paper presents a study to improve the calibration process of a calorimetric sensor for medical application. The sensor has been designed for determination of the heat loss, heat capacity and equivalent thermal resistance of the skin region on which the sensor is applied. Localized constants models have been found to be effective. For a good calibration of the sensor, suitable experiments have been designed, allowing us to determine the thermal quantities with acceptable accuracy. In addition, we propose a new method of operation, which does not require the initial placement of the sensor on the calibration base: the whole measurement is performed with the sensor applied on the skin. The operation and calculation methods were validated by simulations that aim to reproduce the human skin measurement. Finally, an application in the human body is presented, consisting of measuring the heat capacity and equivalent thermal resistance of the wrist.en_US
dc.languageengen_US
dc.relation.ispartofMeasurement: Journal of the International Measurement Confederationen_US
dc.sourceMeasurement: Journal of the International Measurement Confederation [ISSN 0263-2241], v. 186, 110134, (Diciembre 2021)en_US
dc.subject3314 Tecnología médicaen_US
dc.subject.otherDirect Calorimetryen_US
dc.subject.otherHeat Conduction Calorimetersen_US
dc.subject.otherMedical Calorimetryen_US
dc.subject.otherSkin Heat Capacityen_US
dc.subject.otherSkin Heat Lossen_US
dc.subject.otherSkin Thermal Resistanceen_US
dc.titleCalibration and operation improvements of a calorimetric sensor for medical applicationsen_US
dc.typeinfo:eu-repo/semantics/Articleen_US
dc.typeArticleen_US
dc.identifier.doi10.1016/j.measurement.2021.110134en_US
dc.identifier.scopus85115374902-
dc.contributor.orcidNO DATA-
dc.contributor.orcidNO DATA-
dc.contributor.orcidNO DATA-
dc.contributor.orcidNO DATA-
dc.contributor.authorscopusid57200590110-
dc.contributor.authorscopusid57202152954-
dc.contributor.authorscopusid6603271349-
dc.contributor.authorscopusid57263601000-
dc.relation.volume186en_US
dc.investigacionIngeniería y Arquitecturaen_US
dc.type2Artículoen_US
dc.utils.revisionen_US
dc.date.coverdateDiciembre 2021en_US
dc.identifier.ulpgcen_US
dc.description.sjr0,996
dc.description.jcr5,131
dc.description.sjrqQ1
dc.description.jcrqQ1
dc.description.scieSCIE
dc.description.miaricds11,0
item.grantfulltextnone-
item.fulltextSin texto completo-
crisitem.author.deptGIR Termofísica de Líquidos y Calorimetría-
crisitem.author.deptDepartamento de Física-
crisitem.author.deptGIR Termofísica de Líquidos y Calorimetría-
crisitem.author.deptDepartamento de Física-
crisitem.author.deptGIR Termofísica de Líquidos y Calorimetría-
crisitem.author.deptDepartamento de Física-
crisitem.author.orcid0000-0002-6343-6683-
crisitem.author.orcid0000-0002-4890-5947-
crisitem.author.orcid0000-0002-6737-4096-
crisitem.author.parentorgDepartamento de Física-
crisitem.author.parentorgDepartamento de Física-
crisitem.author.parentorgDepartamento de Física-
crisitem.author.fullNameRodríguez De Rivera Socorro, Pedro Jesús-
crisitem.author.fullNameSocorro Lorenzo, Fabiola Lourdes-
crisitem.author.fullNameRodríguez De Rivera Rodríguez, Manuel Jose M.-
Colección:Artículos
Vista resumida

Google ScholarTM

Verifica

Altmetric


Comparte



Exporta metadatos



Los elementos en ULPGC accedaCRIS están protegidos por derechos de autor con todos los derechos reservados, a menos que se indique lo contrario.