Identificador persistente para citar o vincular este elemento:
http://hdl.handle.net/10553/107225
Título: | Biomechanical characterization of custom-made dynamic implants fabricated by Electron Beam Melting for anterior chest wall reconstruction | Autores/as: | Fiorucci, Maria Paula Cuadrado Hernández, Alberto Javier Yánez Santana, Manuel Alejandro Martel Fuentes, Oscar Mentado, Belinda Monopoli, Donato |
Clasificación UNESCO: | 3314 Tecnología médica 331402 Prótesis |
Palabras clave: | Custom-made dynamic implant Electron Beam Melting Biomechanical analysis Ti-6Al-4V Chest wall reconstruction |
Fecha de publicación: | 2021 | Publicación seriada: | Materials and Design | Resumen: | Large thoracic defects need to be reconstructed to restore inner organs protection and normal ventilation. Early rigid implants have provided the stabilization of the ribcage; however, those have been associated with breathing restrictions. The evolution of additive manufacturing has enabled the production of 3D custom-made thoracic implants. This has led to case reports on reconstructions with these prostheses, particularly for large anterior resections. A novel design of thoracic implant with dynamic capacity has already been reported, with promising short-term outcomes. However, specific biomechanical studies are needed to clarify its mechanical behaviour. A study of the evolution of the design of dynamic thoracic implants was carried out and such implants were biomechanically tested. Furthermore, finite element analyses were carried out to obtain a simple and reliable model to predict the implant behaviour, considering a rib and its costal cartilage. In the models, the stiffness and stress distribution along the implant and the bone showed that the reconstructions exhibited adequate mechanical behaviour. One of the designs provided a flexibility that closely matched the native model and the maximum stress values did not exceed the 30% of the yield strength of Ti-6Al-4V. The implants strength was demonstrated to be sufficient under tested conditions. | URI: | http://hdl.handle.net/10553/107225 | ISSN: | 0264-1275 | DOI: | 10.1016/j.matdes.2021.109758 | Fuente: | Materials and Design [ISSN 0264-1275], v. 206, 109758, (Agosto 2021) |
Colección: | Artículos |
Citas de WEB OF SCIENCETM
Citations
6
actualizado el 24-nov-2024
Visitas
225
actualizado el 23-nov-2024
Descargas
179
actualizado el 23-nov-2024
Google ScholarTM
Verifica
Altmetric
Comparte
Exporta metadatos
Los elementos en ULPGC accedaCRIS están protegidos por derechos de autor con todos los derechos reservados, a menos que se indique lo contrario.