Identificador persistente para citar o vincular este elemento: http://hdl.handle.net/10553/105775
Campo DC Valoridioma
dc.contributor.advisorRuiz Santana, Sergioes
dc.contributor.advisorHernández Socorro, Carmen Rosaes
dc.contributor.authorGonzález López, Samueles
dc.date.accessioned2021-03-15T15:32:10Z-
dc.date.available2021-03-15T15:32:10Z-
dc.date.issued2021-
dc.identifier.otherTercer Ciclo-
dc.identifier.urihttp://hdl.handle.net/10553/105775-
dc.descriptionPrograma de Doctorado en Investigación en Biomedicina por la Universidad de Las Palmas de Gran Canariaen_US
dc.description.abstractObjetivo: evaluar la seguridad y utilidad de los catéteres PICC implantados mediante la cuantificación de las complicaciones durante la inserción y el uso del catéter, así como la cumplimentación del tratamiento. Métodos: estudio de cohorte prospectiva de 5 años realizado en un hospital universitario de tercer nivel, en pacientes adultos sometidos a inserción de PICC. Se registraron las complicaciones en la implantación y durante el uso de los catéteres PICC, fundamentalmente bacteriemias asociadas al catéter vascular (BACV), incluidas las bacteriemias relacionadas con el catéter (BRCV) y bacteriemias primarias (BP), así como las trombosis venosas profundas (TVP). Los predictores independientes de complicaciones se evaluaron mediante análisis multivariante. Resultados: se insertaron un total de 1.142 PICC, con 153.191 días de catéter (mediana 79 días). No se identificó ninguna complicación mayor durante la inserción del catéter. Las complicaciones durante el uso del catéter incluyeron 66 casos de BACV (5,78%, 0,43 ‰ días de catéter), 38 de BRCV (3,33%, 0,25 ‰ días de catéter), 28 BP (2,45%, 0,18 ‰ días de catéter) y 23 TVP (2,01%, 0,15 ‰ días de catéter). La nutrición parenteral (OR 3,40, IC 95% 1,77-6,52) y el ingreso en el Servicio de Hematología (OR 4,90, IC 95% 2,25-10,71) se asociaron de forma independiente con BRCV y BP, respectivamente. El ingreso a cargo de Hematología (OR 12,46; IC del 95%: 2,49-62,50) u Oncología (OR 7,89; IC del 95%: 1,77-5,16) se asoció de forma independiente con TVP. El 81,3% de los PICC se retiró sin fallo del catéter, fundamentalmente por finalización del tratamiento. Solo dos pacientes murieron por complicaciones relacionadas por el catéter. Conclusiones: los PICC son dispositivos seguros ya que muestran una baja tasa de complicaciones trombóticas e infecciosas. Además, la ausenciade complicaciones mayores durante la inserción supone una importante ventaja con respecto a otros catéteres centrales. Han resultado también útiles para la cumplimentación del tratamiento del paciente.en_US
dc.description.abstractObjective: To assess safety and usefulness of implanted PICC catheters by quantifying complications during insertion and use, as well as compliance with treatment. Methods: 5-year prospective cohort study at tertiary care teaching hospital. Catheter-associated bloodstream infection (CABSI) includingcatheter-related bloodstream infection (CRBSI) and primary bacteremia (PB), and upper extremity deep vein thrombosis (UEDVT) were recorded. Independent predictors of complications were assessed by multivariate analysis. Results: A total of 1,142 PICCs were inserted, with 153,191 catheter days (median 79 days). No complicationswere identifiedduring insertion procedure. Complications during use included 66 cases of CABSI (5.78%, 0.43‰ catheter days), 38 of CRBSI (3.33%, 0.25‰ catheter days), 28 PB (2.45%, 0.18‰ catheter days), and 23 UEDVT (2.01%, 0.15‰ catheter days). The median time to infection was 24, 41 and 60 days for CRBSI, PB and UEDVT, respectively. Parenteral nutrition (OR 3.40, 95% CI 1.77-6.52) and admission to the hematology ward (OR 4.90, 95% CI 2.25-10.71) were independently associated with CRBSI and PB, respectively. Admission to the hematology (OR 12.46, 95% CI 2.49-62.50) or to the oncology (OR 7.89, 95% CI 1.77-35.16) wards was independently associated with UEDVT. 81.3% of PICCs were removed without catheter failure, mainly due to the end of treatment. Only two patients died of complications. Conclusions: PICCs are safe devices as they show a low rate of thrombotic and infectious complications. Furthermore,the absence of major complications during insertion is an important advantage over other central catheters. They have also been useful for the compliance of the patient's treatment.en_US
dc.languagespaen_US
dc.subject32 Ciencias médicasen_US
dc.subject3201 Ciencias clínicasen_US
dc.subject.otherCatéter central de inserción periféricaes
dc.subject.otherBacteriemia asociada a catéter vasculares
dc.subject.otherBacteriemia relacionada con catéter vasculaes
dc.subject.otherBacteriemia primariaes
dc.subject.otherTrombosis venosa profundaes
dc.titleCatéteres venosos centrales de inserción periférica. Estudio de su seguridad y utilidades
dc.typeinfo:eu-repo/semantics/doctoralThesisen_US
dc.typeThesisen_US
dc.contributor.departamentoDepartamento de Ciencias Médicas y Quirúrgicases
dc.contributor.facultadFacultad de Ciencias de La Saluden_US
dc.investigacionCiencias de la Saluden_US
dc.type2Tesis doctoralen_US
dc.utils.revisionen_US
dc.identifier.matriculaTESIS-1871233es
dc.identifier.ulpgcen_US
dc.contributor.buulpgcBU-MEDes
dc.contributor.programaPrograma de Doctorado en Investigación en Biomedicina por la Universidad de Las Palmas de Gran Canaria-
item.fulltextCon texto completo-
item.grantfulltextopen-
crisitem.advisor.deptGIR IUIBS: Grupo de investigaciones infecciosas, nutricionales e inflamatorias en pacientes hospitalarios / Study Group on infectious, nutritional and inflammatory diseases in hospitalized patients-
crisitem.advisor.deptIU de Investigaciones Biomédicas y Sanitarias-
crisitem.advisor.deptDepartamento de Ciencias Médicas y Quirúrgicas-
crisitem.advisor.deptGIR IUIBS: Grupo de investigaciones infecciosas, nutricionales e inflamatorias en pacientes hospitalarios / Study Group on infectious, nutritional and inflammatory diseases in hospitalized patients-
crisitem.advisor.deptIU de Investigaciones Biomédicas y Sanitarias-
crisitem.advisor.deptDepartamento de Ciencias Clínicas-
crisitem.author.fullNameGonzález López, Samuel-
Colección:Tesis doctoral
miniatura
Adobe PDF (5,59 MB)
Vista resumida

Visitas

975
actualizado el 30-dic-2023

Descargas

3.832
actualizado el 30-dic-2023

Google ScholarTM

Verifica


Comparte



Exporta metadatos



Los elementos en ULPGC accedaCRIS están protegidos por derechos de autor con todos los derechos reservados, a menos que se indique lo contrario.