Identificador persistente para citar o vincular este elemento: http://hdl.handle.net/10553/74890
Campo DC Valoridioma
dc.contributor.authorMartín Rincón, Marcosen_US
dc.contributor.authorLópez Calbet, José Antonioen_US
dc.date.accessioned2020-10-20T10:14:48Z-
dc.date.available2020-10-20T10:14:48Z-
dc.date.issued2020en_US
dc.identifier.issn1664-042Xen_US
dc.identifier.otherScopus-
dc.identifier.urihttp://hdl.handle.net/10553/74890-
dc.description.abstract© Copyright © 2020 Martin-Rincon and Calbet.The maximal oxygen uptake ((Formula presented.) O2max) is the primary determinant of endurance performance in heterogeneous populations and has predictive value for clinical outcomes and all-cause mortality. Accurate and precise measurement of (Formula presented.) O2max requires the adherence to quality control procedures, including combustion testing and the use of standardized incremental exercise protocols with a verification phase preceded by an adequate familiarization. The data averaging strategy employed to calculate the (Formula presented.) O2max from the breath-by-breath data can change the (Formula presented.) O2max value by 4–10%. The lower the number of breaths or smaller the number of seconds included in the averaging block, the higher the calculated (Formula presented.) O2max value with this effect being more prominent in untrained subjects. Smaller averaging strategies in number of breaths or seconds (less than 30 breaths or seconds) facilitate the identification of the plateau phenomenon without reducing the reliability of the measurements. When employing metabolic carts, averaging intervals including 15–20 breaths or seconds are preferable as a compromise between capturing the true (Formula presented.) O2max and identifying the plateau. In training studies, clinical interventions and meta-analysis, reporting of (Formula presented.) O2max in absolute values and inclusion of protocols and the averaging strategies arise as imperative to permit adequate comparisons. Newly developed correction equations can be used to normalize (Formula presented.) O2max to similar averaging strategies. A lack of improvement of (Formula presented.) O2max with training does not mean that the training program has elicited no adaptations, since peak cardiac output and mitochondrial oxidative capacity may be increased without changes in (Formula presented.) O2max.en_US
dc.languagespaen_US
dc.relation.ispartofFrontiers in Physiologyen_US
dc.sourceFrontiers in Physiology [EISSN 1664-042X], v. 11, (Septiembre 2020)en_US
dc.subject32 Ciencias médicasen_US
dc.subject320501 Cardiologíaen_US
dc.subject.otherBreath-By-Breathen_US
dc.subject.otherCalibrationen_US
dc.subject.otherCardiopulmonary Exercise Testingen_US
dc.subject.otherIndirect Calorimetryen_US
dc.subject.otherMetabolic Carten_US
dc.subject.otherPerformanceen_US
dc.subject.otherRamp Exerciseen_US
dc.subject.otherReproducibilityen_US
dc.titleProgress Update and Challenges on VO2max Testing and Interpretationen_US
dc.typeinfo:eu-repo/semantics/reviewen_US
dc.typeArticleen_US
dc.identifier.doi10.3389/fphys.2020.01070-
dc.identifier.scopus85091025648-
dc.contributor.authorscopusid56841673800-
dc.contributor.authorscopusid7004323423-
dc.identifier.eissn1664-042X-
dc.relation.volume11en_US
dc.investigacionCiencias de la Saluden_US
dc.type2Reseñaen_US
dc.description.numberofpages8en_US
dc.utils.revisionen_US
dc.date.coverdateSeptiembre 2020en_US
dc.identifier.ulpgces
dc.description.sjr1,32
dc.description.jcr4,566
dc.description.sjrqQ2
dc.description.jcrqQ1
dc.description.scieSCIE
item.fulltextCon texto completo-
item.grantfulltextopen-
crisitem.author.deptGIR IUIBS: Rendimiento humano, ejercicio físico y salud-
crisitem.author.deptIU de Investigaciones Biomédicas y Sanitarias-
crisitem.author.deptDepartamento de Educación Física-
crisitem.author.deptGIR IUIBS: Rendimiento humano, ejercicio físico y salud-
crisitem.author.deptIU de Investigaciones Biomédicas y Sanitarias-
crisitem.author.deptDepartamento de Educación Física-
crisitem.author.orcid0000-0002-3685-2331-
crisitem.author.orcid0000-0002-9215-6234-
crisitem.author.parentorgIU de Investigaciones Biomédicas y Sanitarias-
crisitem.author.parentorgIU de Investigaciones Biomédicas y Sanitarias-
crisitem.author.fullNameMartín Rincón, Marcos-
crisitem.author.fullNameLópez Calbet, José Antonio-
Colección:Reseña
miniatura
Adobe PDF (4,04 MB)
Vista resumida

Citas SCOPUSTM   

18
actualizado el 21-abr-2024

Visitas

96
actualizado el 13-abr-2024

Descargas

201
actualizado el 13-abr-2024

Google ScholarTM

Verifica

Altmetric


Comparte



Exporta metadatos



Los elementos en ULPGC accedaCRIS están protegidos por derechos de autor con todos los derechos reservados, a menos que se indique lo contrario.