Identificador persistente para citar o vincular este elemento: http://hdl.handle.net/10553/134501
Campo DC Valoridioma
dc.contributor.advisorBocher, Philippe-
dc.contributor.advisorNuño, Natalia-
dc.contributor.advisorYanez Santana, Alejandro-
dc.contributor.authorPaknezhad, Mehrdad-
dc.date.accessioned2024-10-23T10:18:37Z-
dc.date.available2024-10-23T10:18:37Z-
dc.date.issued2023en_US
dc.identifier.urihttp://hdl.handle.net/10553/134501-
dc.description.abstractLe comportement mécanique, en particulier l'hétérogénéité des contraintes, des biomatériaux poreux en titane (Ti-6Al-4V) a été étudié en utilisant la technique de corrélation d'images numériques 2D (2D DIC). Trois échantillons cubiques avec une porosité de 75 % ont été fabriqués à l'aide de la fusion laser sélective (SLM), qui est basée sur la technique de laser powder bed fusion (LPBF). Ils ont été testés dans des conditions de chargement en compression quasi-statique jusqu'à un déplacement de 1 mm de la traverse de la machine. Parallèlement à la méthode 2D DIC, un extensomètre de contact a été utilisé pour mesurer le déplacement avec plus de précision. Les graphiques contrainte-déformation apparents pour trois échantillons et trois méthodes ont été obtenus, et il a été constaté que l'échantillon 2 a le module d'élasticité apparent le plus bas tandis que la région linéaire la plus longue, contrairement à l'échantillon 1. Les cartes de déformation et les histogrammes obtenus par OpenDIC et ImageJ a démontré que la répartition des contraintes n'est pas la même non seulement entre les trois faces de chaque échantillon, mais également sur une face spécifique à travers trois échantillons. Ce fait a été analysé au microscope confocal à balayage laser pour trois faces de l'échantillon 3 (avant et après essai). Plus important encore, une analyse avancée des graphiques de déformation pour chaque étage englobant uniquement les entretoises verticales a permis de conclure que bien que chaque étage n'ait pas le même comportement de déformation et la même valeur de déformation maximale parmi trois échantillons, l'étage 2 a la déformation localisée la plus élevée. Enfin, la déformation tardive d'un étage peut être un signe potentiel d'accumulation de contraintes sévères dans quelques entretoises de cet étage, c'est-à-dire l'étage 2.en_US
dc.description.abstractThe mechanical behavior, especially strain heterogeneity, of porous titanium biomaterials (Ti6Al-4V) was studied by using 2D digital image correlation technique (2D DIC). Three cubic samples with 75% porosity were fabricated using selective laser melting (SLM), which is based on laser powder bed fusion (LPBF) technique. They were tested under quasi-static compressive loading condition up to 1 mm displacement of machine crosshead. Along with 2D DIC method, contact extensometer was used to measure displacement more accurately. The apparent stressstrain graphs for three samples and three methods were obtained, and it was found that sample 2 has the lowest apparent elastic modulus while the longest linear region, which is in contrast for sample 1. The strain maps and histograms obtained by OpenDIC and ImageJ software demonstrated that strain distribution is not the same not only among three faces of each sample, but also in one specific face through three samples. This fact was analyzed by laser scanning confocal microscope for three faces of sample 3 (before and after test). Most importantly, advanced analysis of strain graphs for each floor encompassing only vertical struts helped to conclude that although each floor does not have the same strain behavior and peak strain value among three samples, floor 2 has the highest localized strain. Lastly, late deformation of one floor can be a potential sign of severe strain accumulation in few struts of that floor i.e. floor 2.en_US
dc.languageengen_US
dc.source.urihttps://espace.etsmtl.ca/id/eprint/3435/en_US
dc.subject331005 Ingeniería de procesosen_US
dc.subject.otherFabrication additiveen_US
dc.subject.otherStructure poreuse cubiqueen_US
dc.subject.otherHétérogénéité des déformationsen_US
dc.subject.otherTi6Al4Ven_US
dc.subject.otherMéthode des éléments finisen_US
dc.subject.otherEssai de compressionen_US
dc.subject.otherCorrélation d'images numériques en 2Den_US
dc.subject.otherModule d'élasticitéen_US
dc.titleAnalysis of strain heterogeneity in additive manufactured ti6al4v cubic porous structures by experimental testing and finite element methoden_US
dc.title.alternativeAnalyse de l’hétérogénéité des déformations dans des structures poreux cubes Ti6Al4V fabriquées additifs par essais expérimentaux et simulation par éléments finisen_US
dc.typeinfo:eu-repo/semantics/doctoralThesisen_US
dc.typeThesisen_US
dc.typeThesisen_US
dc.typeThesisen_US
dc.typeThesisen_US
dc.typeThesisen_US
dc.identifier.urlhttps://espace.etsmtl.ca/id/eprint/3435/en_US
dc.investigacionIngeniería y Arquitecturaen_US
dc.type2Tesis doctoralen_US
dc.utils.revisionen_US
dc.identifier.ulpgcNoen_US
dc.contributor.buulpgcBU-INGen_US
item.fulltextSin texto completo-
item.grantfulltextnone-
Colección:Tesis doctoral
Vista resumida

Google ScholarTM

Verifica


Comparte



Exporta metadatos



Los elementos en ULPGC accedaCRIS están protegidos por derechos de autor con todos los derechos reservados, a menos que se indique lo contrario.