Identificador persistente para citar o vincular este elemento: http://hdl.handle.net/10553/125744
Campo DC Valoridioma
dc.contributor.advisorCastro Navarro, Noemí-
dc.contributor.advisorMorales De La Nuez, Antonio José-
dc.contributor.authorGarcía Guillén, Aarón-
dc.date.accessioned2023-09-22T08:38:58Z-
dc.date.available2023-09-22T08:38:58Z-
dc.date.issued2023en_US
dc.identifier.otherGestión académica
dc.identifier.urihttp://hdl.handle.net/10553/125744-
dc.description.abstractDue to the type of placenta present in goats does not allows the transfer of antibodies from the mother to the fetus during gestation. For that reason, to ensure a correct passive immune transfer, colostrum intake plays a crucial role in the survival and development of the progeny in this species. Colostrum quality has been studied in deep, and it is well known that there are differences in colostrum composition, including IgG concentration, not only between species, but also within herds. Thus, to prevent the presence of failure of immune passive transfer in goat kids, the IgG concentration of colostrum needs to be checked. ELISA is considered nowadays as standards. However, it has some limitations such as the large time needed as well as the cost among others. So, the development and evaluation of additional techniques looking for the suitability of the results but also the possibilities to be applied on farms. The objectives of this study are to compare the analytical techniques used to determine IgG concentration in goat colostrum, as well as the use of a new method and its application on-farm. To do that, 40 colostrum samples from Majorera goats were analyzed using different techniques (ELISA, Clinic refractometer, Brix refractometer, Instrumental colour and an Alternative method). Descriptive statistics was performed and Saphyro-wik was used to analyze the normality. Pearson and Spearman´s correlation test were used for those variables with normal and non-normal distribution, respectively. Significant differences were set as p≤0.05. No high correlations (>0.6) between the studied techniques with the standard (ELISA) were observed. However, Brix and clinic refractometers were highly correlated (0.91; p<0.001). The Alternative Method tested in this study did not show strong correlation neither with ELISA nor with the any of the refractometers used, although it seems that 550 nm could be the better of the used wavelength. Further studies using more colostrum samples and testing a wider range of wavelengths are neededen_US
dc.languageengen_US
dc.subject3104 Producción Animalen_US
dc.titleGoat colostrum IgG determination: Alternative methods to apply on farmen_US
dc.typeinfo:eu-repo/semantics/bachelorThesisen_US
dc.typeBachelorThesisen_US
dc.contributor.departamentoDepartamento de Patología Animal, Producción Animal, Bromatología y Tecnología de Los Alimentosen_US
dc.contributor.facultadFacultad de Veterinariaen_US
dc.investigacionCiencias de la Saluden_US
dc.type2Trabajo final de gradoen_US
dc.utils.revisionen_US
dc.identifier.matriculaTFT-72634es
dc.identifier.ulpgcen_US
dc.contributor.buulpgcBU-VETen_US
dc.contributor.titulacionGrado en Veterinariaes
item.fulltextSin texto completo-
item.grantfulltextnone-
crisitem.advisor.deptGIR IUSA-ONEHEALTH 4. Producción y Biotecnología Animal-
crisitem.advisor.deptIU de Sanidad Animal y Seguridad Alimentaria-
crisitem.advisor.deptDepartamento de Patología Animal, Producción Animal, Bromatología y Tecnología de Los Alimentos-
crisitem.advisor.deptGIR IUSA-ONEHEALTH 4. Producción y Biotecnología Animal-
crisitem.advisor.deptIU de Sanidad Animal y Seguridad Alimentaria-
crisitem.advisor.deptDepartamento de Patología Animal, Producción Animal, Bromatología y Tecnología de Los Alimentos-
Colección:Trabajo final de grado
Vista resumida

Visitas

72
actualizado el 14-dic-2024

Google ScholarTM

Verifica


Comparte



Exporta metadatos



Los elementos en ULPGC accedaCRIS están protegidos por derechos de autor con todos los derechos reservados, a menos que se indique lo contrario.