Identificador persistente para citar o vincular este elemento:
http://hdl.handle.net/10553/112141
Título: | Heat flow, heat capacity and thermal resistance of localized surfaces of the human body using a new calorimetric sensor | Autores/as: | Rodríguez de Rivera, Pedro Jesús Rodríguez de Rivera, Miriam Socorro, Fabiola Marrero Callicó, Gustavo López Calbet, José Antonio Rodríguez de Rivera, Manuel |
Clasificación UNESCO: | 330790 Microelectrónica | Palabras clave: | Direct Calorimetry Heat Conduction Calorimeters Human Heat Flow Medical Calorimetry Non-Differential Calorimeters, et al. |
Fecha de publicación: | 2021 | Publicación seriada: | Journal of Thermal Analysis and Calorimetry | Resumen: | A non-invasive sensor equipped with a programmable thermostat has been developed to assess in vivo the heat flow transmitted by conduction from human skin to the sensor thermostat. This device enables the assessment of the thermal properties of a 2 × 2 cm2 skin surface with a thermal penetration depth of 3–4 mm. In this work, we report the thermal magnitudes recorded with this sensor in 6 different areas (temple, hand, abdomen, thigh, wrist and heel) of 6 healthy subjects of different genders and ages, which were measured under resting conditions. Heat flow and equivalent thermal resistance are proportionally related to each other and are highly variable in magnitude and different for each zone. The heat capacity is also different for each zone. The heat flow values varied from 362 ± 17 mW at the temple to 36 ± 12 mW at the heel for the same subject, when the sensor thermostat was set at 26 °C. The equivalent thermal resistance ranged from 23 ± 2 K W−1 in the volar area of the wrist to 52 ± 4 KW−1 in the inner thigh area. The heat capacity varies from 4.8 ± 0.4 J K−1 in the heel to 6.4 ± 0.2 J K−1 in the abdomen. These magnitudes were also assessed over a 2 × 1 cm2 second-degree burn scar in the volar area of the wrist. The scar area had 27.6 and 11.6% lower heat capacity and equivalent thermal resistance, respectively, allowing an increased heat flow in the injured area. This work is a preliminary study of the measurement capacity of this new instrument. | URI: | http://hdl.handle.net/10553/112141 | ISSN: | 1388-6150 | DOI: | 10.1007/s10973-021-11062-0 | Fuente: | Journal of Thermal Analysis and Calorimetry [ISSN 1388-6150], (Enero 2021) |
Colección: | Artículo preliminar |
Citas SCOPUSTM
6
actualizado el 24-nov-2024
Citas de WEB OF SCIENCETM
Citations
5
actualizado el 24-nov-2024
Visitas
98
actualizado el 29-jun-2024
Descargas
97
actualizado el 29-jun-2024
Google ScholarTM
Verifica
Altmetric
Comparte
Exporta metadatos
Los elementos en ULPGC accedaCRIS están protegidos por derechos de autor con todos los derechos reservados, a menos que se indique lo contrario.