Identificador persistente para citar o vincular este elemento: http://hdl.handle.net/10553/112238
Título: Corrosion behavior in Ringer solution of several commercially used metal alloys
Autores/as: García Falcón, Carmen Marina 
Gil-Lopez, Tomás
Verdu-Vazquez, Amparo
Mirza Rosca, Julia 
Clasificación UNESCO: 3310 tecnología industrial
Palabras clave: Nickel-based alloys
Metallic biomaterials
Corrosion
Passivity
Dental materials, et al.
Fecha de publicación: 2021
Proyectos: Microscopio Electronico Multifuncional 
Publicación seriada: Anti-corrosion methods and materials 
Resumen: Purpose: This paper aims to analyze the corrosion behavior in Ringer solution of six commercially used Ni-based alloys that are present and commonly used as metallic biomaterials. Design/methodology/approach: The specimens were received in the form of cylindrical ingots and were cut to get five samples of each brand with a cylindrical shape of 2 mm height to conduct the study. In this scientific research, the following techniques were used: open circuit potential, potentiodynamic polarization studies, and electrochemical impedance spectroscopy. Findings: The study findings revealed the passivation tendency of the different specimens. Additionally, when the materials were compared, it was discovered that the decisive factor for high corrosion resistance was the chromium concentration. However, with similar chromium content, the stronger concentration in molybdenum increased the resistance. According to the results obtained in this investigation, the biological safety of the dental materials studied in Ringer solution was considered very high for specimens 1 and 2, and adequate for the other samples. Originality/value: Metal alloys used as biomaterials in contact with the human body should be deeply investigated to make sure they are biocompatible and do not cause any harm. The corrosion resistance of an alloy is the most important characteristic for its biological safety, as all problems arise because of the corrosion process. There is scarce investigation in these Ni-based dental biomaterials, and none found in these commercially used dental materials in Ringer solution.
URI: http://hdl.handle.net/10553/112238
ISSN: 0003-5599
DOI: 10.1108/ACMM-05-2021-2486
Fuente: Anti-corrosion methods and materials [ISSN 0003-5599], v. 68 (4)
Colección:Artículos
Adobe PDF (1,05 MB)
Vista completa

Citas SCOPUSTM   

9
actualizado el 17-nov-2024

Citas de WEB OF SCIENCETM
Citations

7
actualizado el 17-nov-2024

Visitas

91
actualizado el 09-mar-2024

Descargas

207
actualizado el 09-mar-2024

Google ScholarTM

Verifica

Altmetric


Comparte



Exporta metadatos



Los elementos en ULPGC accedaCRIS están protegidos por derechos de autor con todos los derechos reservados, a menos que se indique lo contrario.