Identificador persistente para citar o vincular este elemento:
http://hdl.handle.net/10553/52561
Campo DC | Valor | idioma |
---|---|---|
dc.contributor.author | Calbet, J. A. L. | en_US |
dc.contributor.author | Mortensen, S.P. | en_US |
dc.contributor.author | Munch, G.D.W. | en_US |
dc.contributor.author | Curtelin, D. | en_US |
dc.contributor.author | Boushel, R. | en_US |
dc.contributor.other | Calbet, Jose A | |
dc.contributor.other | Curtelin, David | |
dc.contributor.other | Mortensen, Stefan | |
dc.date.accessioned | 2018-11-30T11:36:03Z | - |
dc.date.available | 2018-11-30T11:36:03Z | - |
dc.date.issued | 2016 | en_US |
dc.identifier.issn | 0905-7188 | en_US |
dc.identifier.uri | http://hdl.handle.net/10553/52561 | - |
dc.description.abstract | To determine the accuracy and precision of constant infusion transpulmonary thermodilution cardiac output (CITT-Q) assessment during exercise in humans, using indocyanine green (ICG) dilution and bolus transpulmonary thermodilution (BTD) as reference methods, cardiac output (Q) was determined at rest and during incremental one- and two-legged pedaling on a cycle ergometer, and combined arm cranking with leg pedaling to exhaustion in 15 healthy men. Continuous infusions of iced saline in the femoral vein (n=41) or simultaneously in the femoral and axillary (n=66) veins with determination of temperature in the femoral artery were used for CITT-Q assessment. CITT-Q was linearly related to ICG-Q (r=0.82, CITT-Q=0.876×ICG-Q+3.638, P<0.001; limits of agreement ranging from -1.43 to 3.07L/min) and BTD-Q (r=0.91, CITT-Q=0.822×BTD+4.481L/min, P<0.001; limits of agreement ranging from -1.01 to 2.63L/min). Compared with ICG-Q and BTD-Q, CITT-Q overestimated cardiac output by 1.6L/min (≈10% of the mean ICG and BTD-Q values, P<0.05). For Q between 20 and 28L/min, we estimated an overestimation <5%. The coefficient of variation of 23 repeated CITT-Q measurements was 6.0% (CI: 6.1-11.1%). In conclusion, cardiac output can be precisely and accurately determined with constant infusion transpulmonary thermodilution in exercising humans. | en_US |
dc.language | eng | en_US |
dc.relation.ispartof | Scandinavian Journal of Medicine and Science in Sports | en_US |
dc.source | Scandinavian Journal Of Medicine & Science In Sports[ISSN 0905-7188],v. 26 (5), p. 518-527 | en_US |
dc.subject | 241106 Fisiología del ejercicio | en_US |
dc.subject.other | Arm exercise | en_US |
dc.subject.other | Blood flow | en_US |
dc.subject.other | Cardiac output | en_US |
dc.subject.other | Exercise | en_US |
dc.subject.other | Humans | en_US |
dc.subject.other | Performance | en_US |
dc.subject.other | Thermistor | en_US |
dc.subject.other | Thermodilution | en_US |
dc.title | Constant infusion transpulmonary thermodilution for the assessment of cardiac output in exercising humans | en_US |
dc.type | info:eu-repo/semantics/Article | es |
dc.type | Article | es |
dc.identifier.doi | 10.1111/sms.12473 | |
dc.identifier.scopus | 84928573097 | |
dc.identifier.isi | 000375077800005 | |
dcterms.isPartOf | Scandinavian Journal Of Medicine & Science In Sports | |
dcterms.source | Scandinavian Journal Of Medicine & Science In Sports[ISSN 0905-7188],v. 26 (5), p. 518-527 | |
dc.contributor.authorscopusid | 7004323423 | |
dc.contributor.authorscopusid | 8591187800 | |
dc.contributor.authorscopusid | 57195758932 | |
dc.contributor.authorscopusid | 56607231500 | |
dc.contributor.authorscopusid | 7003471688 | |
dc.description.lastpage | 527 | - |
dc.identifier.issue | 5 | - |
dc.description.firstpage | 518 | - |
dc.relation.volume | 26 | - |
dc.investigacion | Ciencias Sociales y Jurídicas | en_US |
dc.type2 | Artículo | en_US |
dc.identifier.wos | WOS:000375077800005 | |
dc.contributor.daisngid | 90295 | |
dc.contributor.daisngid | 512474 | |
dc.contributor.daisngid | 4168072 | |
dc.contributor.daisngid | 7404383 | |
dc.contributor.daisngid | 220476 | |
dc.identifier.investigatorRID | H-6693-2015 | |
dc.identifier.investigatorRID | I-4316-2016 | |
dc.identifier.investigatorRID | No ID | |
dc.contributor.wosstandard | WOS:Calbet, JAL | |
dc.contributor.wosstandard | WOS:Mortensen, SP | |
dc.contributor.wosstandard | WOS:Munch, GDW | |
dc.contributor.wosstandard | WOS:Curtelin, D | |
dc.contributor.wosstandard | WOS:Boushel, R | |
dc.date.coverdate | Mayo 2016 | |
dc.identifier.ulpgc | Sí | es |
dc.description.sjr | 1,61 | |
dc.description.jcr | 3,331 | |
dc.description.sjrq | Q1 | |
dc.description.jcrq | Q1 | |
dc.description.scie | SCIE | |
item.grantfulltext | open | - |
item.fulltext | Con texto completo | - |
crisitem.author.dept | GIR IUIBS: Rendimiento humano, ejercicio físico y salud | - |
crisitem.author.dept | IU de Investigaciones Biomédicas y Sanitarias | - |
crisitem.author.dept | Departamento de Educación Física | - |
crisitem.author.orcid | 0000-0002-9215-6234 | - |
crisitem.author.parentorg | IU de Investigaciones Biomédicas y Sanitarias | - |
crisitem.author.fullName | López Calbet, José Antonio | - |
Colección: | Artículos |
Los elementos en ULPGC accedaCRIS están protegidos por derechos de autor con todos los derechos reservados, a menos que se indique lo contrario.