Please use this identifier to cite or link to this item:
http://hdl.handle.net/10553/49129
Title: | Determination of phenol by differential pulse voltammetry with a sepiolite-modified carbon paste electrode | Authors: | Hernández, L. Hernández, P. Sosa, Z. |
UNESCO Clasification: | 2301 química analítica | Keywords: | Physical Chemistry Analytical Chemistry Phenol Inorganic Chemistry Detection Limit |
Issue Date: | 1988 | Publisher: | 0016-1152 | Journal: | Fresenius Zeitschrift für Analytische Chemie | Abstract: | The determinations of phenol is studied by means of a carbon paste electrode modified with 10% sepiolite using DPV. A 10 min preconcentration step was performed at pH 1.5 under open circuit conditions. Measurements were made in another cell by DPV with ΔE=100 mV (sweep rate = 40 mV/s) in 0.02 mol/l KNO3 medium at pH 2. Detection limits (3 σ) of 30 ng/ml were achieved for determinations in orange, lemon and cola drinks. | URI: | http://hdl.handle.net/10553/49129 | ISSN: | 0016-1152 | DOI: | 10.1007/BF00467043 | Source: | Fresenius' Zeitschrift für Analytische Chemie [ISSN 0016-1152], v. 331, p. 525-527 |
Appears in Collections: | Artículos |
SCOPUSTM
Citations
14
checked on Jul 3, 2022
Page view(s)
57
checked on Jun 11, 2022
Google ScholarTM
Check
Altmetric
Share
Export metadata
Items in accedaCRIS are protected by copyright, with all rights reserved, unless otherwise indicated.