Título: Selection of cable economy taking thermal losses into consideration
Autores/as: Toraño, J.
Rodríguez, R. 
Diego, I.
López, L. M.
Clasificación UNESCO: 33 Ciencias tecnológicas
Palabras clave: Electric cables
Electric transmission
Thermal losses
Economic calculation
Fecha de publicación: 2004
Editor/a: 0716-8756
Publicación seriada: Informacion Tecnologica 
Resumen: El objetivo de este artículo es determinar las bases que, de manera simplificada, sirvan de guía para saber cuando es recomendable hacer un análisis económico de una instalación eléctrica teniendo en cuenta las pérdidas térmicas. Ayudándose de una aplicación de software desarrollada para tal fin, se han llevado a cabo un gran número de simulaciones representativas de instalaciones industriales. En cada simulación se partió de la sección obtenida por el cálculo según los tres criterios básicos (caída de voltaje, amperaje y condiciones de cortocircuito) se fue aumentando la sección de cable y se determinó el coste de capital que conllevaba dicho aumento de sección. Por último, dicho coste se comparó con el coste operativo por pérdidas térmicas al utilizar el cable inicial de menor sección. Del estudio se concluye que para potencias medias (aproximadamente 700-800 kW con 4180 V o 75-300 kW con 480 V) dicho análisis económico es muy recomendable.
The objective of this study was to determine as simply as possible the criteria that can serve as a guide for determining when an economic analysis of an electrical installation considering heat losses is required. A large number of simulations representative of industrial installations were carried out using computer software specifically designed for this purpose. Each simulation was begun with a section obtained from calculations made from three basic criteria (voltage drop, current, and short circuit conditions) and then increasing the cable section to determine the increase of the capital cost caused by the increase in the cable section. Finally, this cost was compared with operational cost due to thermal losses when using the initial cable which was smaller in section. It is concluded from the study that for moderate power (approx. 700-2800 kW in 4180 V or 75-300 kW in 480 V) economic analysis is highly recommended.
URI: http://hdl.handle.net/10553/47308
ISSN: 0716-8756
Fuente: Informacion Tecnologica[ ISSN 0716-8756], v. 15, p. 23-29