Título: Calculating steady-state operating conditions for doubly-fed induction generator wind turbines
Autores/as: Medina Padrón, José Fernando 
Feijóo Lorenzo, Andrés Elías
Palabras clave: Farms
Model
Fecha de publicación: 2010
Editor/a: 0885-8950
Publicación seriada: IEEE Transactions on Power Systems 
Resumen: In this paper an analysis of steady-state operation in doubly-fed induction generator (DFIG) wind turbines (WT) is presented. A method based on the Newton-Raphson (NR) algorithm is proposed for obtaining the steady-state electrical variables of the machine under certain given conditions. It is of interest in the load flow analysis, when these machines are present in electrical system, but also for gaining initial conditions for dynamic analysis, as the variables in dynamic models must coincide with those in stationary models during steady-state operation. Results obtained from the stationary analysis allow us to initialize electrical variables for use in a third-order dynamic model of the DFIG. The method presented in this paper does not make use of a d-q reference frame. Some approximations made in other works have not been assumed here, which allowed us to obtain more accurate results.
URI: http://hdl.handle.net/10553/43091
ISSN: 0885-8950
DOI: 10.1109/TPWRS.2009.2036853
Fuente: IEEE Transactions on Power Systems[ISSN 0885-8950],v. 25 (5371953), p. 922-928
Colección:Artículos
Vista completa

Google ScholarTM

Verifica

Altmetric


Comparte



Exporta metadatos



Los elementos en ULPGC accedaCRIS están protegidos por derechos de autor con todos los derechos reservados, a menos que se indique lo contrario.