Title: Mejora de la integración de energías renovables en un sistema insular mediante la incorporación de baterías : caso de la red eléctrica Lanzarote-Fuerteventura
Other Titles: Renewable energy integration improvement in an island system by installing batteries : case study of the Lanzarote-Fuerteventura electric grid
Authors: Mejías García, Lorena Del Carmen
Director: Medina Padrón, José Fernando 
UNESCO Clasification: 3322 Tecnología energética
531205 Energía
Keywords: BESS
CCT
Redes aisladas
Energía eólica
Aerogeneradores en jaula de ardilla, et al
Issue Date: 2018
Abstract: Los sistemas insulares presentan una red de infraestructuras eléctricas débilmente malladas. Por ello, cuando se inyectan grandes cantidades de energía renovable esa estabilidad puede verse gravemente afectada. En primer lugar, el tiempo crítico de cortocircuito trifásico (CCT) es estudiado junto con el aumento de la integración de energía eólica, con aerogeneradores en jaula de ardilla. Para resolver las carencias que un sistema eléctrico aislado presenta, es clave introducir sistemas de almacenamiento de energía en baterías (BESS). De manera que, se alcance una mejora de la eficiencia energética, analizándola por medio de los valores obtenidos de CCT. Los parámetros que se consideran para el CCT son sobretensiones, sobrefrecuencias, subfrecuencias y porcentaje de deslastre de carga.
The insular energy systems have a grid infrastructure weakly meshed. For this reason, stability is seriously affected when large amount of renewable energy is being flowed into the grid. Firstly, critical clearing time (CCT) is studied along with the increase in renewable energies integration. This study considers the use of squirrel cage induction generators. Battery energy storage systems (BESS) have been installed so that the isolated electrical system drawbacks is resolved. Thus, renewable energy integration improvement is achieved. Energy efficiency improvement are analysed by means of CCT values. Over voltage, over frequency, under frequency and amount of load shedding are considered as parameters to the CCT value.
Description: Máster en Eficacia Energética (MUEE)
Department: Departamento de Ingeniería Eléctrica
Institute: Instituto Universitario de Sistemas Inteligentes y Aplicaciones Numéricas en Ingeniería (SIANI)
Degree: Máster Universitario en Eficiencia Energética
URI: http://hdl.handle.net/10553/41962
Appears in Collections:Trabajo final de máster
Thumbnail
Memoria
Adobe PDF (4,91 MB)

En el caso de que no encuentre el documento puede ser debido a que el centro o las/os autoras/es no autorizan su publicación. Si tiene verdadero interés en el contenido del mismo, puede dirigirse al director/a o directores/as del trabajo cuyos datos encontrará más arriba.